• Title/Summary/Keyword: L-필터

Search Result 449, Processing Time 0.023 seconds

Calibration of CR-39 for Measurement of Radon in Air (공기중의 라돈 농도 측정을 위한 CR-39의 교정)

  • Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.18-22
    • /
    • 1989
  • In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{\pm}0.09(pCi/l)\;day/(Tr/cm^2)$.

  • PDF

A Master and Slave Control Strategy for Parallel Operation of Three-Phase UPS Systems with Different Ratings (다른 정격용량을 가진 3상 UPS 시스템의 병렬운전을 위한 주종제어 기법)

  • 이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.341-349
    • /
    • 2004
  • A parallel operation of Uninterruptible Power Supply(UPS) systems is used to increase power capacity of the system or to secure higher reliability at critical loads. In the conventional parallel operation, the load-sharing control to maintain the current balance is the most important, since the load-sharing is very sensitive to discord between components of each module, amplitude/phase difference, line impedance, output LC filter, and so on. To solve these problems various control algorithms are researching. However, these methods cannot apply to the different ratings of UPS. In the case, master and slave control algorithm for parallel operation is adequate. However, if the UPS ratings are different, the value of passive filters L, C is different, and it affects the sharing of current. This paper presents general problems of conventional parallel operation systems, and control strategy for parallel operation with different ratings. The validity of the proposed control strategy is investigated through simulation and experiment in the parallel operation system with two 3-phase UPS systems.

Optimized LCL filter Design Method of Utility Interactive Inverter (계통연계형 인버터의 LCL필터 최적 설계기법)

  • Jung, Sang-Hyuk;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

Design and Fabrication of Multi-layer LTCC Bandpass Filter using DGS (DGS 구조를 이용한 적층 LTCC 대역통과 필터의 설계 및 제작)

  • 송희석;박규호;조영균;김형석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.172-177
    • /
    • 2004
  • In this paper, DGS(Defected Ground Structure) is applied to multi-layer structure using LTCC(Low Temperature Co-fired Ceramics). Sprial DGS is adopted in order for size-reduction and higher quality factor, the multi-layer DGS has the same characteristics as the planar DGS. Multi-layer bandpass filter of new shape is confiured using two multi-layer spiral DGS and is designed with no via-hole for the simple process. 5.25 GHz Wireless LAN bandpass filter is designed and fabricated, the insertion loss of the filter is measured less than 1.5 dB, and the size is 2.0 mm${\times}$1.2 mm${\times}$1.1 mm(L${\times}$W${\times}$H).

Biofiltration of Ammonia Gas from Composting Using Sawdust as Biofilter Media (퇴비화 암모니아 가스의 톱밥 바이오 필터 매체에 의한 생물학적 탈취)

  • Hong Ji Hyung;Park Keum Joo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.107-115
    • /
    • 2003
  • Dairy manure amended with crop and forest residues (moisture 69% wet basis, C/N 22) was composted in a 605 L pilot-scale vessel using continuous air flow (56 L/min) for 19 days. Three pilot-scale sawdust biofilters (moisture 63%, pH 5.0) were built to clean biological waste gas from the composting process. For each methods, two replicated experiments were monitored over a period of three weeks. The system was evaluated to determine the biofilter media depth that would be adequate for compost odour reduction. The compost air cleaning was measured based on ammonia gas concentration before and after passing through the biofilter. Ammonia gas removal efficiency over 3 weeks was 42, 75 and 87% at sawdust biofilter media depth levels of 202, 400 and 600 mm, respectively. Each sawdust biofilter was operated at a moisture content in the range of 60~62% (wb), a temperature from 15 to $25^{\circ}C$, an average pressure drop from 240 to 340 Pa and a detention time from 60 to 180 seconds during the biofiltration process.

Realization of the Real-time Hybrid Optical Interconnection Using a Genetic Algorithm (GA 학습기법을 적용한 실시간 복합 광 연결의 실현)

  • Yoon, Jin-Seon;Kim, Nam
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.38-46
    • /
    • 2000
  • In this paper, a grating to apply for the optical interconnection is designed using a Genetic Algorithm(GA) as a robust and an efficient schema. A hybrid optical interconnection system architecture is implemented by the liquid crystal panel as a programmable spatial light modulator. As the result of geometrical transformation to obtain the quantitative data for $3{\times}3$ spot beams at CCD array detector by optical experiment truthfully, the mean of beam intensity as a gray level is 202, the maximum value is 225, the minimum value is 186, and a uniformity is quantitatively $1.93{\times}10^{-1}$ similar to simulation result.

  • PDF

Design of a Triplexer for Mobile Communication (AMPS, GPS, US-PCS 대역용 Triplexer 설계)

  • 이재선;윤태순;김기병;이종철;박재영;고영준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.327-334
    • /
    • 2004
  • In this paper, a triplexer for Advanced Mobile Phone Service(AMPS), United States-Personal Communication Services(US-PCS), and Global Positioning System(CPS) is designed using L and C lumped elements. The triplexer shows the insertion loss of 0.6 ㏈, 1.1 ㏈, and 1.6 ㏈ for AMPS, US-PCS, and GPS bands, respectively. Also, it shows the attenuation characteristic of less than 18 ㏈, and the VSWR of less than 2.0 through the all pass-band.

The Study on the experimental of a development of the filtering system for particle/gas phase contaminants (입자/가스상 오염물질 필터링 장치 개발에 관한 실험적 연구)

  • Kim, Tae-Hyung;Nam, Seung-Baeg;Ha, Jong-Pil;Moon, In-Ho;Cho, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.387-392
    • /
    • 2007
  • In this study performance evaluation of filtering system were made on the clean air supply system to show it's ability to eliminate the air contaminants. The evaluation was conducted inside the 3,200CMH scale wind tunnel and under the same environment that is effected by yellow dust and similar particle and gas phase contaminants in semi-conductor and FPDs industries. (1) The result of experimental for particle contaminants, the particle removing efficiency was 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05, electrified voltage : (+)5.8kV with electric charger and (-)3.5kV with eliminator. (2) The gas phase removing efficiency for $NH_3$ : 80%, $SO_X$ : 70% and $NO_X$ : 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05.

  • PDF

Evaluation of Swine Wastewater Pretreatment Using Anaerobic Filter (Anaerobic Filter에 의한 양돈폐수의 전처리 특성 평가)

  • Kang, Ho;Moon, Seo-yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.7
    • /
    • pp.418-425
    • /
    • 2015
  • Anaerobic Filters (AF) packed with porous ceramic floating media were operated at different operational conditions to identify the feasibility of the renewable bioenergy, methane production from swine wastewater and to verify the suitability of effluent from anaerobic filters for the subsequent biological nitrogen and phosphorus removal. Stepwise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) with influent TCOD concentration of 14,000 mg/L were utilized at mesophilic temperature. The maximum methane productivity of 1.74 volume of $CH_4$ per volume of reactor per day (v/v-d) was achieved at an hydraulic retention time (HRT) of 0.5 day (OLR 28 g TVS/L-d). Based on the biogas production, the highest total volatile solids (TVS) removal efficiency of 63% was obtained at an HRT of 3 days (OLR 4.67 g TVS/L-d), however based on the result from the effluent total chemical oxygen demand (TCOD) analysis, the highest TCOD removal efficiency of 75% was achieved. The effluent alkalinity concentration over the range of 2,050~2,980 mg/L as $CaCO_3$ at all operational conditions, could compensate the alkalinity destruction caused by nitrification. The effluent from the anaerobic filter operated under the HRT of 2 days showed the COD/TKN ratio of 15~35 and COD/TP ratio of 38~56. Therefore effluent C/N/P ratio is able to satisfy the optimum COD/TKN ratio of greater than 8.0 and COD/TP ratio of 33 for the subsequent biological nutrient removal.

Disinfection of Phytophthora spp. in Recycling Nursery Irrigation Water by Ozone Treatment (오존처리에 의한 폐양액내 Phytophthora spp. 멸균)

  • Lee, Jung-Sup;Han, Kyoung-Suk;Park, Jong-Han;Cheong, Seung-Ryong;Jang, Han-Ik
    • Research in Plant Disease
    • /
    • v.12 no.3
    • /
    • pp.272-277
    • /
    • 2006
  • Recycled irrigation water is a primary inoculum source of Phytophthora spp. and is capable of spreading propagules throughout nursery cultivation. Ozonation is commonly used to disinfest the recycled irrigation water; however, ozone has not been fully researched as a disinfectant for this purpose. In this study, zoospores of four species of Phytophthora were exposed for $1{\sim}9$ min to free available ozone at $0.1{\sim}0.3,\;0.5{\sim}0.7,\;0.9{\sim}1.2,\;1.4{\sim}1.7\;and\;1.9{\sim}2.2mg/l$. Zoospores, mycelial fragments, and culture plugs of P. nicotianae also were exposed to ozone concentrations ranging from 0.1 to 2.2 mg/l for periods ranging from 1 to 9 min. In addition, ozonated water was assayed monthly in 2004 and 2005 at two commercial nurseries, and quarterly in the first year at two other nurseries in Suwon, for ozone and survival of pythiaceous species using a selective medium. No zoospores of any species tested survived endpoint free ozone at 1.4 mg/l while limited mycelial fragments of P. nicotianae survived at 1.9 mg/l, and mycelial plugs treated at the same level of ozone were able to produce few sporangia. Phytophthora spp. were recovered only from nursery irrigation water with levels of free ozone at 0.3 mg/l or lower. The results of this study are essential for improving current ozonation sterilization.