Abstract
The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.
Keywords
optimized LCL filter design method; LCL filter; utility-interactive inverter; weighting factor; critical load;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Standard for Interconnecting Distributed Resources With Electric Power Systems, IEEE Std. 1547.2-2008.
2 Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE Std. 519-1992.
3 I.J. Gabe, V.F. Montagner, and H. Pinheiro, "Design and implementation of a robust current controller for VSI connected to the grid through an LCL filter," IEEE Trans. on Power Electron., Vol. 24, No. 6, pp. 1444-1452, Jun. 2009   DOI   ScienceOn
4 D. Xu, L. Cao, and X. Zhu, "An Improved Control Strategy for Grid-Connected Voltage Source Inverters With an LCL Filter," IEEE Trans. on Power Electron., Vol. 23, No. 7, pp. 1899-1906, July. 2008   DOI   ScienceOn
5 T. Wang, Z. Ye, G. Sinha, and X. Yuan, "Output filter design for a grid-interconnected three-phase inverter," in Proc. IEEE PESC, Vol. 2, pp. 779-784, 2003.
6 M. Liserre, F. Blaabjerg, and S. Hansen, "Design and control of an LCL-filter based active rectifier", IEEE Ind. Applicat., Vol. 1, pp. 297-307, Oct. 2001.
7 J. Park, M. Chi, H. Kim, T. Chun, and E. Nho, "LCL filter Design for Grid-connected PCS Using Total Harmonic Distortion and Ripple Attenuation Factor," The Transactions of the Korean Institute of Power Eleectronics Vol. 15, No. 3, pp. 235-243, July 2010.   과학기술학회마을   DOI   ScienceOn
8 B. Cho, S. Sul, H, Yoo, and S. Lee, "LCL Filter Design and Control for Grid-connected PWM Converter," IEEE ECCE2011, pp. 756-763.
9 M. Liserre, A. Dell'Aquila, and F. Blaabjerg, "Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier," IEEE Trans. on Power Electron., Vol. 19, No. 1, pp. 76-86, Jan. 2004.   DOI   ScienceOn
10 J. Kwon, S. Yoon, S. Choi, "Indirect Current Control for Seamless Transfer of Three-Phase Utility Interactive Inverters," IEEE Trans. on Power Electron., Vol. 27, No. 2, pp. 773-781, Feb. 2012.   DOI   ScienceOn
11 S. Jung, Y. Kim, H. Oh, S. Choi, "Optimized LCL filter Design of Utility Interactive Inverter Considering Voltage Quality of Local Load," 2011 Power Electronics Annual Conference, pp. 65-66.
12 N. Mohan, W. P. Robbin, and T. Undeland, "Power Electronics: Converters, Applications, and Design," 2nd ed. New York: Wiley, 1995.