• 제목/요약/키워드: K5 system

검색결과 31,957건 처리시간 0.065초

A Positioning Mooring System Design for Barge Ship Based on PID Control Approach

  • Kim, Youngbok
    • Journal of Power System Engineering
    • /
    • 제17권5호
    • /
    • pp.94-99
    • /
    • 2013
  • This paper presents some experimental results about Position Mooring (PM) system applied to the barge ship. In PM operation, the station keeping in surge, sway of vessel is provided by the mooring system. In this paper, a system, consisting of a barge vessel and mooring lines, is mathematically modeled. The position and orientation of vessel is controlled by changing the tensions in the mooring lines. The PID control strategy is applied to evaluate the efficiency of proposed system. Experimental result which corresponds to the applied control strategy is presented and discussed.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

Development of 1-axis Exciter for a Seat Vibration Test of Agricultural Tractors(I) - Design of PID Controller for Position Control of 1-axis Exciter - (농용트랙터용 운전자 좌석 진동 시험을 위한 1축 가진 시험기 개발(I) - 1축 가진 시험기 위치 제어를 위한 PID 제어기 설계 -)

  • Yu, Ji-Hoon;Choi, Young-Kyun;Lee, Kyu-Cheol;Kim, Young-Joo;Ryu, Young-Sun;Ryuh, Kwan-Hee
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.305-314
    • /
    • 2009
  • The purpose of this paper was to design an effective control system of 1-axis exciter for a seat vibration test of agricultural tractors using MATLAB simulation. The developed simulation model was composed with a hydraulic pump, a hydraulic servo valve, a hydraulic cylinder and load system. Also it was verified by comparing the simulation results with experimental results of actual control system in order to optimize the control performance. And in order to improve its control performance, the designed PID controller in this research was tuned using Ziegler-Nichols 2nd law and zero's moving method of PID controller's transfer function. As the result of these research, the developed position control system was able to control the system's position accurately within 5% errors.

A Case Report of Multiple System Atrophy in a Cerebellar Ataxia Patient Suffering from Gait Disturbance Treated with Korean Medicine (보행장애를 주소로 하는 소뇌형 다계통 위축증 환자의 한방 치료 1례)

  • Woo, Seong-jin;Baek, Kyung-min;Jang, Woo-seok
    • The Journal of Internal Korean Medicine
    • /
    • 제37권5호
    • /
    • pp.806-814
    • /
    • 2016
  • Objective: To describe the effect of Korean medicine on gait disturbance in a patient with multiple system atrophy and cerebellar ataxia. Methods: We observed a 75-year-old female patient who had multiple system atrophy and cerebellar ataxia. The patient was treated with Korean medicine, including acupuncture, moxibustion, and herbal medicine (Yukmijihwang-tang-gamibang and Boyanghwano-tang-gamibang) for 38 days. We evaluated the patient with the Korean version of the Berg Balance Scale (K-BBS), the Unified Multiple System Atrophy Rating Scale (UMSARS), and the Numeric Rating Scale-11 (NRS-11). Results: After treatment, the patient’s symptoms were improved. The K-BBS score increased from 9 to 19, while the UMSARS score decreased from 16 to 12 in Part I, from 15 to 7 in part Ⅱ, and from 4 to 3 in part Ⅳ. The NRS-11 score of gait disturbance decreased from 10 to 5. Conclusions: Korean medicine may be an effective treatment for gait disturbance in multiple system atrophy with cerebellar ataxia.

LARGE STORAGE SYSTEM FOR HIGH-SPEED RECORDING OF OBSERVED DATA (관측 데이터의 고속기록을 위한 대용량 저장시스템)

  • OH SE-JIN;ROH DUK-GYOO;KIM KWANG-DONG;SONG MIN-GYU;JE DO-HEUNG;WI SEOG-OH;KIM TAE-SUNG;WHITNEY ALAN R.
    • Publications of The Korean Astronomical Society
    • /
    • 제19권1호
    • /
    • pp.83-92
    • /
    • 2004
  • In this paper, we introduce the development of the large storage system in order to record the observed space radio signal in the Korean VLBI Network(KVN) with high-speed. The KVN is the Very Long Baseline Interferometery(VLBI) to observe the birth of star, the structure of space by constructing radio telescope with diameter 21m at the Seoul, Ulsan, Jeju from 2001 to 2007 years. To do this, Korea Astronomy Observatory joined the international consortium for developing the high-speed large storage system(Mark 5), which is developed by MIT Haystack observatory. The Mark 5 system based on hard disk has to record up to 1 Gbps the observed space radio signal. The main features of Mark 5 system are as follows; First it is able to directly record the input data to the hard disk without PC1(Peripheral Component Interconnect) internal bus, and the second, it has two hard disk banks, which are able to hot-swap ATA/IDE type very cheap up to 1 Gbps recording and playback. The third is that it follows the international VLBI standard interface hardware(VSI-H). Therefore it can be connect directly the VSI-H type system at the input/output. Finally it also supports e- VLBI(Electronic-VLBI) through the standard Gigabits Ethernet connection.

Use of the Yeast 1.5-Hybrid System to Detect DNA-Protein-Protein Interaction

  • Kim, Sook-Kyung;Han, Jin-Hee
    • Journal of Microbiology
    • /
    • 제38권2호
    • /
    • pp.113-116
    • /
    • 2000
  • Escherichia coli F plasmid partition apparatus is composed of two trans-acting proteins (SopA and SopB) and one cis-acting DNA sequence (sopC). The SopB-sopC complex has been suggested to serve a centromere-like function through its interaction with chromosomally encoded proteins which remain to be identified. In this paper, we are introducing a new yeast 1.5-hybrid system which assembles the two-hybrid and one-hybrid system as a mean to find and additional component of the F plasmid partition system, interacting with DNA (sopC)-bound SopB protein. The results indicates that this system is a promising one, capable of selecting an interacting component.

  • PDF

A Study on the Polymerization of Dicyclopentadiene Production and Applied to Boats Materials (p-DCPD 제조 및 보트소재적용 연구)

  • Kim, Si-Young;Koo, Su-Jin;Ju, Chang-Sik;Park, Joo-Young
    • Journal of Power System Engineering
    • /
    • 제19권5호
    • /
    • pp.86-92
    • /
    • 2015
  • p-DCPD were prepared by in-suit ROMP polymerization using $MoCl_5$ and $Et_2AlCl$. The results showed that $MoCl_5:Et_2AlCl:DCPD$ mole ratio of 1:2.0:350 had the curing-time of 60sec and crosslinking degree of 90.44%. The curing time of DCPD polymerization by $MoCl_5/Et_2AlCl$ was shortened, and monomer conversion and crosslinking degree were decreased with temperature and the number of moles of $MoCl_5$ and $Et_2AlCl$. $MoCl_5$ and $Et_2AlCl$ is damaged its function by the reaction with the air in the atmosphere and did't proceed the polymerization properly.

High-resolution Simulation of Meteorological Fields over the Coastal Area with Urban Buildings (건물효과를 고려한 연안도시지역 고해상도 기상모델링)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Kang, Yoon-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제26권2호
    • /
    • pp.137-150
    • /
    • 2010
  • A meso-urban meteorological model (Urbanized MM5; uMM5) with urban canopy parameterization (UCP) was applied to the high-resolution simulation of meteorological fields in a complex coastal urban area and the assessment of urban impacts. Multi-scale simulations with the uMM5 in the innermost domain (1-km resolution) covering the Busan metropolitan region were performed during a typical sea breeze episode (4~8 August 2006) with detailed fine-resolution inputs (urban morphology, land-use/land-cover sub-grid distribution, and high-quality digital elevation model data sets). An additional simulation using the standard MM5 was also conducted to identify the effects of urban surface properties under urban meteorological conditions. Results showed that the uMM5 reproduced well the urban thermal and dynamic environment and captured well the observed feature of sea breeze. When comparison with simulations of the standard MM5, it was found that the uMM5 better reproduced urban impacts on temperature (especially at nighttime) and urban wind flows: roughness-induced deceleration and UHI (Urban Heat Island)-induced convergence.

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.