• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.037 seconds

A Study on the Surface Characteristics of Phenolic Resin by Water Treatment (수처리에 의한 페놀수지의 표면특성에 관한 연구)

  • Choi, Chung-Seog;Shong, Kil-Mok;Kim, Hyung-Rae;Kim, Dong-Woo;Kim, Hyang-Kon;Kim, Dong-Ook
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1431-1433
    • /
    • 2002
  • In this paper, we studied the characteristics of surface structure of phenolic resin by water treatment. Phenolic resin which is used as indoor insulators is easily deteriorated by humidity. Water treated sample for 200 hours is subjected to the penetration of water and cracked partially. Water treated sample for 400 hours is found more cracks than that for 200 hours. The initial leakage current of virgin sample is 0.11A, that of water treated sample for 200 hours is 0.07A, and that of water treated sample for 400 hours is 0.05A. FT-IR analysis indicates that absorption peak of carbonyl group appears in virgin sample, but the absorption peak does not appear in water treated sample for 200 hours.

  • PDF

A study on the Tracking Characteristics of Contaminated Insulating Materials of RCD (오염된 누전차단기 절연재료의 트래킹 특성에 관한 연구)

  • Lee, Chun-Ha;Ok, Kyung-Jae;Kim, Shi-Kuk;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.67-71
    • /
    • 2008
  • This experimental study showed the tracking characteristics of contaminated insulating materials of RCD. Electrolytes is made by IEC(International Electrotechnical Commission) 60589, NaCl added to deionized water as each 0.1 wt%. The used test equipment is application to KS(Korean Industrial Standard) C IEC 60112. The used samples is RCD(Residual Current Device) of tree companies. It is investigated carbonic electric conductive pass growth time and tracking growth form that contaminated insulators materials of RCD. As a result, carbonic electric conductive pass growth time and tracking growth form was different each companies. Track growth time of contaminated insulating materials was faster than non-contaminated.

Preperation of Silicon Carbide Oxidation Protection Film on Carbon Thermal Insulator Using Polycarbosilane and Its Characterization (폴리카보실란을 이용하여 탄소단열재에 코팅한 실리콘카바이드 코팅막의 내산화 특성)

  • Ahn, Su-Bin;Lee, Yoonjoo;Bang, Jung-Won;Shin, Dong-Geun;Kwon, Woo-Teck
    • Korean Journal of Materials Research
    • /
    • v.27 no.9
    • /
    • pp.471-476
    • /
    • 2017
  • In order to improve the high temperature oxidation resistance and lifespan of mat type porous carbon insulation, SiC was coated on carbon insulation by solution coating using polycarbosilane solution, curing in an oxidizing atmosphere at $200^{\circ}C$, and pyrolysis at temperatures up to $1200^{\circ}C$. The SiOC phase formed during the pyrolysis process was converted into SiC crystals as the heat treatment temperature increased, and a SiC coating with a thickness of 10-15 nm was formed at $1600^{\circ}C$. The SiC coated specimen showed a weight reduction of 8.6 % when it was kept in an atmospheric environment of $700^{\circ}C$ for 1 hour. On the other hand, the thermal conductivity was 0.17 W/mK, and no difference between states before and after coating was observed at all.

Nano Scale Compositional Analysis by Atom Probe Tomography: II. Applications on Electronic Devices and Nano Materials (Atom Probe Tomography를 이용한 나노 스케일의 조성분석: II. 전자소자 및 나노재료에서의 응용)

  • Jung, Woo-Young;Bang, Chan-Woo;Jang, Dong-Hyun;Gu, Gil-Ho;Park, Chan-Gyung
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Atom Probe Tomography (APT) can provide 3-dimensional information such as position and chemical composition with atomic resolution. Despite the ability of this technique, APT could not be applied for poor conductive materials such as semiconductor. Recently APT has dramatically developed by applying the laser pulsing and combining with Focused Ion Beam (FIB). The invention and combination of these techniques make possible site-specific sample preparation and permit the investigation of various materials including insulators. In this paper, we introduced the recently achieved state of the art applications of APT focusing on Si based FET devices, LED devices, low dimensional materials.

A Study on Electric Field Dependence of Tree Shape in Low Density Polyethylene (저밀도폴리에틸렌에서 트리 형상의 전계의존성에 관한 연구)

  • 김재환;박창옥;윤헌주
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • Internal insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, we have studied on Electric Field dependence of tree shape in Low Density Polyethylene about treeing phenomena occurring on the high electrical field. As the result, under the reasoning that the growing of tree supposing when the inner part of tree is either dielectrec or conductor has the intermediate characteristics between dielectrec and conductor, theoretically investicated results well according with the experimental results.

  • PDF

Fabrication of MISFET type hydrogen sensor for high Performance (고성능 MISFET형 수소센서의 제작과 특성)

  • Kang, K.H.;Park, K.Y.;Han, S.D.;Choi, S.Y.
    • Journal of Hydrogen and New Energy
    • /
    • v.15 no.4
    • /
    • pp.317-323
    • /
    • 2004
  • We fabricated a MISFET using Pd/NiCr gate for the detecting of hydrogen gas in the air and investigated its electrical characteristics. To improve stability and high concenntration sensitivity and remove the blister generated by the penetration of hydrogen atoms Pd/NiCr catalyst gate metal are used as dual gate. To reduce the gate drift voltage caused by the inflow of hydrogen, the gate insulators of sensing and reference FFET were constructed with double insulation layers of silicon dioxide and silicon nitride. The hydrogen response of MISFET were amplified with the difference of gate voltages of both MISFET. To minimize the drift and the noise, we used a OP177 operational amplifier. The sensitivity of the Pd/NiCr gate MISFET was lower than that of Pd/Pt gate MISFET, but it showed good stability and ability to detect high concentration hydrogen up to 1000ppm.

A study on transient stability of 345 KV power transmission line (345KV 송전선의 과도안정도계산 I)

  • 이재숙
    • 전기의세계
    • /
    • v.18 no.1
    • /
    • pp.24-29
    • /
    • 1969
  • This is preliminary study concerning the future construction and operation of 345KV power transmission line in Korea which will be added to the existing 161KV power system by the end of 1970 in order to increase the power carrying capacity between Seoul and Pusan area; 350 kilo meters aparts, in accordance with the ambitious second five years power development schedule of Korea Electric Company. The result of this study says that an intermidiate switching station should be installed at the middle position of the line to improve the transient stability of the system, considerable amount of capacitors or synchronous condenser are to be installed to reduce the voltage drop at receving end of line during the heavy load hours, and also in some measure to avoid the voltage rise by self-excitation of power generators during the light load hours and while energizing the line. This is the first attempt to realize the EHV power transmission line in Korea so that the additional study is necessary on the kind and size of conductors, the necessary number of insulators and the suitable clearance distances between conductor and steel tower or earth from the technical and economical view points. These are necessary steps to be taken by the writer before getting into the calculation on the transient stablity of the power system.

  • PDF

Switching conduction characteristics of PI LB Film in MIM junctions (Polyimide(PI)LB막의 MIM구조 소자내에서의 switching전도특성)

  • ;;Mitsumasa Iwamoto
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.176-183
    • /
    • 1995
  • The present work is concerned with the switching conduction characteristics of PI LB films in metal insulator metal sandwiches. By applying various DC voltage bias to MIM junctions, conduction characteristics of junctions can be changed between the high-voltage low-current(off) condition, the low-voltage high-current (on) condition and the medium(mid) condition. Switching conduction characteristics can be also observed in MIM junctions employing some aromatic compounds as insulators. Switching conduction characteristics is assumed to be owing to the existence of aromatic rings, space charge in films, impurities on metal-insulator interface, and difference in work functions of base and top electrodes metal. To study the conduction process of on, off, and mid conductions, we measured I-V, d$^{2}$V/d I$^{2}$-V characteristics of junctions with several different top electrodes under various temperatures. Small conductance changes of junctions can be measured by observing the second derivative, d$^{2}$V/dI$^{2}$, of I-V curve. A dynamical technique is used to get the second derivatives. That is, a finite modulation of the current is applied to the junctions and the second harmonic of the voltage is detected.

  • PDF

A Pollution Cycle Method to Evaluate the Electrical Properties of Outdoor Insulators (옥외 절연물의 전기적 특성 평가를 위한 오손주기시험법)

  • Lee, Won-Yeong;Choi, Nam-Ho;Han, Sang-Ok;Park, Gang-Sik;Choi, Tea-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.6-9
    • /
    • 2001
  • In this research, a experiment was performed to evaluate the electrical properties of outdoor insulator with the pollution cycle method. Cycle test methods such as DCM of STRI, IEC 61109 compared with pollution cycle method. Using dimatic properties of Korea peninsula, we could get the optimal condition for the pollution cycle method. As the factor, clean and saline fog, voltage, rainfall and drying was chosen. The applied voltage is 13,2 kV, the salinity of salt solution was changed from 0.1 wt% to 1.5 wt% and one cycle is about 4 hours. To ensure the reproducibility and reliability, experiments repeated 4 times. The leakage current was measured with Lab VIEW and the ESDD was measured with brushwiping method. This experiment could ensure superiority of pollution cycle method which developed through the result of this experiment and we could know the relationship between ESDD, leakage current and relative humidity.

  • PDF

The Modelling of Carbon Plume by Pulsed-laser ablation Method (PLAD법에 의한 탄소 플라즈마의 모델링)

  • So, Soon-Youl;Chung, Hae-Deok;Lee, Jin;Park, Gye-Choon;Kim, Chang-Sun;Moon, Chae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.41-45
    • /
    • 2006
  • The study on laser-ablation plasmas has been strongly interested in fundamental aspects of laser-solid interaction and consequent plasma generation. In particular, this plasma has been widely used for the deposition of thin solid films and applied to the semiconductors and insulators. In this paper, we developed and discussed the generation of carbon ablation plasmas emitted by laser radiation on a solid target, graphite. The progress of carbon plasmas by laser-ablation was simulated using Monte-Carlo particle model under the pressures of vacuum, 1 Pa, 10 Pa and 66 Pa. At the results, carbon particles with low energy were deposited on the substrate as the pressure becomes higher. However, there was no difference of deposition distributions of carbon particles on the substrate regardless of the pressure.

  • PDF