수처리에 의한 페놀수지의 표면특성에 관한 연구

A Study on the Surface Characteristics of Phenolic Resin by Water Treatment

  • 최충석 (한국전기안전공사부설 전기안전시험연구원) ;
  • 송길목 (한국전기안전공사부설 전기안전시험연구원) ;
  • 김형래 (한국전기안전공사부설 전기안전시험연구원) ;
  • 김동우 (한국전기안전공사부설 전기안전시험연구원) ;
  • 김향곤 (한국전기안전공사부설 전기안전시험연구원) ;
  • 김동욱 (한국전기안전공사부설 전기안전시험연구원)
  • Choi, Chung-Seog (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO)) ;
  • Shong, Kil-Mok (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO)) ;
  • Kim, Hyung-Rae (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO)) ;
  • Kim, Dong-Woo (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO)) ;
  • Kim, Hyang-Kon (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO)) ;
  • Kim, Dong-Ook (Electrical Safety Laboratory Research Institute(ESLRI attached to KESCO))
  • 발행 : 2002.07.10

초록

In this paper, we studied the characteristics of surface structure of phenolic resin by water treatment. Phenolic resin which is used as indoor insulators is easily deteriorated by humidity. Water treated sample for 200 hours is subjected to the penetration of water and cracked partially. Water treated sample for 400 hours is found more cracks than that for 200 hours. The initial leakage current of virgin sample is 0.11A, that of water treated sample for 200 hours is 0.07A, and that of water treated sample for 400 hours is 0.05A. FT-IR analysis indicates that absorption peak of carbonyl group appears in virgin sample, but the absorption peak does not appear in water treated sample for 200 hours.

키워드