A study on the Tracking Characteristics of Contaminated Insulating Materials of RCD

오염된 누전차단기 절연재료의 트래킹 특성에 관한 연구

  • Published : 2008.12.31

Abstract

This experimental study showed the tracking characteristics of contaminated insulating materials of RCD. Electrolytes is made by IEC(International Electrotechnical Commission) 60589, NaCl added to deionized water as each 0.1 wt%. The used test equipment is application to KS(Korean Industrial Standard) C IEC 60112. The used samples is RCD(Residual Current Device) of tree companies. It is investigated carbonic electric conductive pass growth time and tracking growth form that contaminated insulators materials of RCD. As a result, carbonic electric conductive pass growth time and tracking growth form was different each companies. Track growth time of contaminated insulating materials was faster than non-contaminated.

본 논문은 국내에서 사용되고 있는 누전차단기 외함 절연재료의 오염에 의한 트래킹 특성을 연구하였다. IEC (International Electrotechnical Commission) 60589의 방법으로 만들어진 0.1 wt% NaCl 용액을 이용하여 KSC IEC 60112의 고체절연재료의 내트래킹 및 비교트래킹지수 측정 방법을 응용하여 실험을 하였다. 실험에 사용된 시료는 3개 제조사의 누전차단기를 사용하였으며, 누전차단기의 절연재료가 오염되었을 때 탄화도전로 발생시간 및 트래킹 발생형태를 분석하였다. 연구결과, 제조사별로 탄화도전로의 발생 시간 및 트래킹 발생형태가 상이하게 나타났다. 오염된 차단기의 절연재료의 트래킹 발생 시간이 정상시료보다 빠르게 나타났다.

Keywords

References

  1. 소방방재청, "전국 화재 통계 분석"(2006)
  2. 김형래, 강원대학교, "저전압에 의해 소손된 페놀수지의 트래킹 특성에 관한 연구", 석사학위논문, pp.11-12(2001)
  3. 최충석, 송길목, 김동우, "누전차단기 외함 전원측 단자사이의 트래킹에 의한 탄화특성 분석", 한국화재소방학회, Vol.17, No.4, pp.13-19(2003)
  4. KS C 3004의 20, "절연체의 내유실험"(2001)
  5. IEC 60589, "Methods of Test for the Determination of Ionic Impurities in Electrical Insulating Materials by Extraction with Liquids"(1977)
  6. KS C IEC 60112, "고체 절연 재료의 내트래킹 및 비교트래킹 지수 측정 방법"(2005)
  7. 옥경재, 이춘하, "오염된 절연재료의 트래킹 특성에 관한 연구", 한국화재소방학회, Vol.21, No.3, pp.97-103(2007)