• Title/Summary/Keyword: Installation direction

Search Result 403, Processing Time 0.03 seconds

Furniture & Lighting Exhibition Design (가구/조명 전시 디자인)

  • Yim, Oh-Yon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.157-158
    • /
    • 2007
  • This is an interior design for a furniture & lighting design exhibition. The concept of design is to secure the smooth flow planning of an audience and effective direction of an exhibit Design content include 1) installation(passage of light) to guide an audience from entrance to right side of the exhibition space to prohibit the flow dispersion and keep smooth continual circulation flow plan 2)image-wall to introduce exhibition 3)installation to help the global understanding of exhibit 4)exhibition stand design considering proper height of audience's eye.

  • PDF

Advanced electricity electron information communication facility obstacle factor and countermeasure investigation in digital age (디지털시대의 첨단 전기 전자 정보 통신설비 장애요인과 대책 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.110-115
    • /
    • 2004
  • Examine merits and demerits and obstacle factor that exist to all direction of digital infratechnology that is supplied on industry whole according to development special quality of computer by development of computer and Information Technology and electricity electron information communication facility that basic impulse insulation level does not exist examined scorched earth or an interference problem factor and countermeasure of semiconductor degauss of factor and electricity electron information transmission system that is numbed or causes system down.

  • PDF

An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow) (곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동))

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle (면진장치 설치각도에 따른 아치구조물의 지진응답)

  • Kim, Gee-Cheol;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.

The Study on Optimum Installation angle of Photovoltaic Arrays using the Expert System (전문가시스템을 이용한 태양광 어레이의 최적설치 각도에 관한 연구)

  • Yu, Gwon-Jong;Lee, Yo-Han;So, Jung-Hun;Seong, Se-Jin;Yu, Byung-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.107-115
    • /
    • 2007
  • The measured solar radiation incident on tilted surfaces has been widely used as important solar radiation data in installing photovoltaic arrays. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar photovoltaic systems. This is because the performance of the solar photovoltaic systems is much affected by angle and direction of incident rays. The expert system can predict the optimum installation angle of photovoltaic arrays with those factors.

A Study on the Workship Special Light Installation Case (종교시설 특수예배조명 설치 사례연구)

  • Lee, Jang-Weon;Lee, Kyung-Han;Kwon, Hyeok-Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.1
    • /
    • pp.87-90
    • /
    • 2015
  • Find out about the Status and future direction of the latest special lighting, through the installation of special lighting for worship practices used in religious institutions. by applying the LED installation practices, Looked for in the past with other functional features. When replacing halogen lighting with LED lighting, According to the illumination economic evaluation, Confirmed, to be an approximately 25% reduction in the applicable. with functional factors of LED luminaires the feed will be applied more in the future.

A Study on an Analysis of Noise Reduction Effects using the tentatively Installed Sound-absorbing Materials in Metro Tunnel (도시철도 터널내 흡음재 시험설치 및 소음저감효과 분석에 관한 연구)

  • Hong, Chul-Kee;Jeong, Ri-Taek;Kim, Byeong-Hong
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.125-131
    • /
    • 2008
  • This research tries to analyze and investigate the effects of the noise reduction test for the sound-absorbing materials installed tentatively on Metro Line 5. Though the noise reduction effects of each sound-absorbing material showed that there was about $2{\sim}5\;dB$ compared with before and after of the tentative installation, it shows that the noise reduction effects are reducing because of the section change condition such as dust absorption and the rail abrasion as time passes after the tentative installation. Also, many difficulties are occurring in the maintenance of the orbit facilities because of the installation of sound-absorbing materials. Though various abroad products for noise reduction are imported like this, the researches for the noise reduction effect increase for this and the improvement direction are being required because of the poor circumstance of the efficiency aspect compared to the economic investment effect because those are not suited to the character of domestic Metro.

  • PDF

A experimental Study on the Reinforced Coil Development for the Efficiency Improvement of a Single Phase Induction Motor (단상유도전동기의 효율 개선을 위한 강화코일 개발에 관한 실험적 연구)

  • Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.78-84
    • /
    • 2010
  • The efficiency of system with a built-in coil is improved as (1) the total coil flux increases, (2) the space distribution of coil flux is closer to the sinusoidal wave and (3) the direction of coil flux flow becomes more inherent with the original direction at the same condition. Every turn RC(Reinforced Coil) is composed of OC having original region and two IC's strengthening bidirectionally the inner part flux in order to maintain the symmetry with origin. This way we will realize the inherent flux direction and the sinusoidal closeness as well. Accordingly RC type is obtained by connecting the pure OC's and RC's in just turns to be closer to sinusoidal flux wave. We proved experimentally the usefulness of reinforced coil to improve the efficiency of SPIM.

Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions (결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석)

  • Jung, Su-Bok;Cho, Yong-Sun;Choi, Myoung-Ho;Choi, Hyo-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • We investigated the current limiting and the recovery characteristics of a flux-lock type superconducting fault current limiter(SFCL) according to the winding directions. The flux-lock type SFCL consists of two coils. The primary coil was wound in parallel to the secondary coil through an Iron core, and the secondary coil was connected with the superconducting element in series. We have changed the winding direction of coils to compare the resistive type SFCL with the flux-lock type SFCL. The current limiting and the recovery characteristics were dependent on the winding direction. The quenching time in the additive polarity winding was faster than that of the subtractive polarity winding or the resistivity type. A consumed energy in a superconducting element was represented as $W= VIt=I^2Rt$. We found that there was a difference in the consumed energies in accordance with winding types because of differences in voltages imposed on a superconducting element in accordance with a winding direction.

An Accurate Direction Finding Technology Using a Phase Comparison and Time Difference of Arrival (위상비교와 시간차를 복합한 정밀 방향탐지 기술)

  • Lim, Joong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5208-5213
    • /
    • 2011
  • In this paper, we proposed a new direction finding(DF) technology using TDOA(time-difference of arrival) and PDOA(phase difference of arriving signal) method. The proposed technology has a good DF accuracy without DF ambiguity. TDOA or PDOA technology is used to the most of intelligence systems in 21 century. The principle of TDOA is to receive a signal with two parallel antennas, measure the time difference of arrival signal, and converse the time difference to the direction of incident signal. Those technology make a DF system small size but the DF accuracy is low into short antenna installation distance. The principle of PDOA is similar to TDOA except measuring the phase difference of arrival signal, These technology get a good DF accuracy in short antenna installation distance but have a DF ambiguity. The proposed DF method is simulated into DF system operation environment with noise, and has a good DF accuracy.