• 제목/요약/키워드: Installation depth

검색결과 361건 처리시간 0.022초

쇼윈도 조명환경에 관한 (A Study on the Illumination Environment in Show Window)

  • 김현지;안옥거
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.32-37
    • /
    • 1993
  • This study investigates the relationship between size, illumination ,and display of show window. The average width, heigh, and depth of show windows in Taegu area were 341.3, 233.4, and 125.8cm, respectively. As light source, halogen lamp was most frequently used, followed by fluorescent lamp and incandescence lamp. In the actual illumination, however, a combined use of more than 2 light sources was common. Further, a local illumination method, e.g., spot light, was generally adopted. The thought of employers and employees in fashion shops about display and illumination was examined aw well. On the whole, the necessity and importance of display were well recognized but the fact that the illumination should be hamonized with other factors such as color and arrangement of goods was underestimated.

  • PDF

고성능저가형 지중열교환기 개발연구 (Development of High Peformance Geothermal heatexchanger)

  • 안형준;백성권;임성균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.470-473
    • /
    • 2007
  • Geothermal heat exchanger(GHEX) is a major component of Geothermal heat pump system(GSHPs). In Common, We use the vertical type GHEX in Korea. But vertical type GHEX needs a high cost for installation, because of drilling the hole which has 200m depth at max. So, We suggest the use of horizontal type GHEX. When we construct buildins, We excavate the ground and we can install the horizontal type GHEX at the excavated underground. It's very cheap and convenient method compare to vertical type GHEX installation. This study is peformed to estimate the peformance of horizontal type GHEX and to analyze effects of heat exchanger types and undergroundwater. As the result, slinky type GHEX has a 66% efficiency compare to vertical type GHEX and mat type has a 201% efficiency at the undergroundwater zone.

  • PDF

Effective Route Decision of an Automatic Moving Robot(AMR) using a 2D Spatial Map of the Stereo Camera System

  • Lee, Jae-Soo;Han, Kwang-Sik;Ko, Jung-Hwan
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.45-53
    • /
    • 2006
  • This paper proposes a method for an effective intelligent route decision for automatic moving robots(AMR) using a 2D spatial map of a stereo camera system. In this method, information about depth and disparity map are detected in the inputting images of a parallel stereo camera. The distance between the automatic moving robot and the obstacle is detected, and a 2D spatial map is obtained from the location coordinates. Then the relative distances between the obstacle and other objects are deduced. The robot move automatically by effective and intelligent route decision using the obtained 2D spatial map. From experiments on robot driving with 240 frames of stereo images, it was found that the error ratio of the calculated distance to the measured distance between objects was very low, 1.52[%] on average.

반구형 축소모델을 이용한 접지전극 주변의 전위상승 분석 (Analysis of the Potential Rises near Grounding Electrodes using Semisplere type scale Model)

  • 이복희;백영환;이봉;김기복
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2008
  • This paper describes the ground surface potential profiles near the object to be grounded. The hemisphere water tank was used to simulate the. scale model. As a result, the ground surface potential near the ground electrode was considerably raised. In particular the ground surface potential at the just upper part of ground rod was higher than other part. The ground surface potential was lowered with increasing the buried depth of ground rod.

  • PDF

실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석 (Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test)

  • 안태봉
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

와전류에 의한 저주파 자기장 차폐 성능 평가 (Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.124-128
    • /
    • 2010
  • In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as $2.4{\times}2.4{\times}2.4[m^3]$ and 12[mm] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[${\mu}T$] and measured magnetic field inside shielding room for 0.01~10[Hz]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[Hz] and 5 times to 11 times for 5~10[Hz].

전력계통 연계형 태양광 발전시스템의 고조파 및 플리커의 측정 및 분석에 관한 연구 (A Study on the Harmonics and Flicker Measurements and Analysis of the Grid Connected Photovoltaic Power System)

  • 김경철;김용관
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.48-57
    • /
    • 2012
  • This paper analyzes the characteristic of gird connected photovoltaic power generation system which is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring and 3-sec measuring for 7 days. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. So, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이주홍;이일무;김주락
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

접지봉 설치에 따른 전주 주변의 전위분포 (Potential Distribution near Concrete Pole According to the position of Ground Rod)

  • 이복희;정현욱;최종혁;조성철;백영환;이규선;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.342-346
    • /
    • 2006
  • This paper describes ground surface potential rises and touch voltage. The more soil resistivity of upper layer is lower, the more ground surface potential rise is increased. Ground surface potential rise is increased as the buried depth of ground rod in lowered. Ground surface potential rises were measured in the test site and compared with results by CDEGS program. Touch voltages according to the separation distance of ground rod were measured in four directions. Touch voltages were remarkably changed by separation distance and contact position.

  • PDF

유도전동기 부하를 고려한 배전계통의 전압저하(sag)특성 (The Characteristic of Voltage Sags in Distribution System with Induction Motor Loads)

  • 오용택;김진성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.69-73
    • /
    • 2006
  • The calculation of depth and duration of a sag is in both methods based on two simple assumptions. One is that due to the short circuit, the voltage drops to a low value immediately magnitude. Another is that when the fault is cleared. the voltage recovers immediately. These assumptions, however, do not hold in the case of a substantial part of the load consisting of electrical motors like in many industrial power systems. During the short circuit, the motors will slow down. Their reacceleration after the fault will increase the load current and thus prolong the voltage sag. This paper will discuss some of the aspects of the influence of induction motors on voltage sags.

  • PDF