• Title/Summary/Keyword: Initial factor

Search Result 1,884, Processing Time 0.027 seconds

Theoretical Calculation and Experimental Verification of the Hf/Al Concentration Ratio in Nano-mixed $Hf_xAl_yO_z$ Films Prepared by Atomic Layer Deposition

  • Kil, Deok-Sin;Yeom, Seung-Jin;Hong, Kwon;Roh, Jae-Sung;Sohn, Hyun-Cheol;Kim, Jin-Woong;Park, Sung-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.2
    • /
    • pp.120-126
    • /
    • 2005
  • We have proposed a characteristic method to estimate real composition when multi component oxide films are deposited by ALD. Final atomic concentration ratio was theoretically calculated from the film densities and growth rates for $HfO_2$ and $Al_2O_3$ using ALD processed HfxAhOz mms.W e have transformed initial source feeding ratio during deposition to fins] atomic ratio in $Hf_xAl_yO_z$ films through thickness factors ($R_{HFO_2}$ ami $R_{Al_2O_3}$) ami concentration factor(C) defined in our experiments. Initial source feeding ratio could be transformed into the thickness ratio by each thickness factor. Final atomic ratio was calculated from thickness ratio by concentration factor. It has been successfully confirmed that the predicted atomic ratio was in good agreement with the actual measured value by ICP-MS analysis.

Development of a Scale to Measure Reproductive Health Promoting Behavior of Undergraduates (대학생의 생식건강증진행위 측정도구 개발)

  • Jo, Ho Yoon;Kim, Young Hae;Son, Hyun Mi
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.5
    • /
    • pp.29-43
    • /
    • 2014
  • Objectives: This study was to develop a reliable and valid instrument measuring the reproductive health promoting behavior of undergraduates. Methods: The initial questionnaires were made of 106 items from four domains through literature review. All questionnaire items were revised by an expert group and a pilot test. Data were collected using the revised initial questionnaire of men's 58 items and female's 64 items from 634 male and 685 female undergraduate students. The collected questionnaires were analyzed by factor analysis using varimax rotation to evaluate the construct validity. Results: According to the gender, two measurement were invented and analysed separately. Four common factors consisting of 'safe sex', 'sexual responsibility', 'genital health management' and 'STD prevention' were discovered in both groups. The 'genital hygiene' factor was added as a female factor. Male students' scale was made up 4 factors 16 items and female students' scale was made up 5 factors 18 items. Cronbach's alpha for male scale was estimated to be .892 and female scale to be .882. Conclusions: This scale will make it possible to measure the level of reproductive health among Korean university students. This scale may be useful for developing effective methods of education as well as policy programs for improving the reproductive health of Korean university students.

Development and Validation of the Nurse Needs Satisfaction Scale Based on Maslow's Hierarchy of Needs Theory (Maslow의 욕구위계이론에 근거한 간호사 욕구만족도 측정도구 개발 및 타당화)

  • Kim, Hwa Jin;Shin, Sun Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.6
    • /
    • pp.848-862
    • /
    • 2020
  • Purpose: The purpose of this study was to develop an instrument to evaluate the needs satisfaction of nurses and examine its validity and reliability. Methods: The initial items for the instrument were developed through a literature review and interviews, using the conceptual framework of Maslow's hierarchy of needs theory. The initial items were evaluated for content validity by 14 experts. Four hundred and eighty-six clinical nurses participated in this study through offline and online surveys to test the reliability and validity of the instrument. The first evaluation (n = 256) was used for item analysis and exploratory factor analysis, and the second evaluation (n = 230) was used to conduct a confirmatory factor analysis and to assess the criterion-related validity and internal consistency of the instrument. Test-retest reliability was analyzed using data from 30 nurses. Results: The final instrument consisted of 30 items with two sub-factors for five needs that were identified through the confirmatory factor analysis. The criterion-related validity was established using the five need satisfaction measures (r = .56). Cronbach's α for total items was .90, and test-retest reliability was .89. Conclusion: The findings from this study indicate that this instrument has sufficient validity and reliability. This instrument can be used for the development of nursing interventions to improve the needs satisfaction of clinical nurses.

A Study on the Estimation of Load Distribution Factors Considering Excavation Methods and Initial Stress Conditions (굴착방법과 초기지압 조건을 고려한 하중분배율의 산정 연구)

  • Park, Yeon-Jun;Ryu, Il-Hyung
    • Tunnel and Underground Space
    • /
    • v.21 no.3
    • /
    • pp.192-204
    • /
    • 2011
  • In this study, 3-D analyses were conducted while taking every construction stage into account. Then 2-D analyses were conducted which yield the same results with the 3-D results. The crown settlement normalized by the ultimate value was compared during the process to overcome the discrepancy caused by different dimensions. When a bench or a core is left uncut to give extra support to the face and eventually the whole excavation boundary, this extra supporting effect also has to be included in the analysis. In this study, this effect is also implemented in terms of the load distribution factor. When the length of the bench is very short compared to the diameter of the tunnel in such cases as in short bench cut or in mini-bench cut, the supporting effect of the face does not disappear even after the bench is completely excavated and supported since the face is still too close to the point of interest. The 4th load distribution factor was defined to stand for the advance of the face after the completion of the excavation cycle. The 4th load distribution factor turned out to be very useful in determining the load distribution factors when a tunnel is excavated by bench cut with various bench lengths under different initial conditions.

Contact non-linear finite element model analysis of initial stability of mini implant (접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구)

  • Yoon, Hyun-Joo;Jung, Ui-Won;Lee, Jong-Suk;Kim, Chang-Sung;Kim, Jung-Moon;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Sung-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

Study of Management and Environmental Factors Affecting Medical Expense Reduction (의료기관 운영요인과 환경요인이 진료비 삭감율에 미치는 영향에 관한 연구)

  • Yang, Yu-Jeong
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.493-502
    • /
    • 2012
  • This study aimed to determine the management and environmental factors affecting medical expense reduction. For analysis, medical expenses were divided into hospitalization expenses and outpatient treatment expenses, and the rate of medical expense reduction was classified into initial and final reduction rates. Data were collected through a direct survey among 205 directors of independent health insurance review departments of hospital-level medical institutions in Korea. The results of the study are discussed below: In the analysis, differences in the initial and final reduction rates of hospitalization expenses and outpatient treatment expenses were compared. The results showed that, in hospitalization expenses, the initial and final reduction rates were both significantly affected by the following management factors: number of beds, number of departments, number of personnel reviewing health insurance cases, and total number of employees. Further, in outpatient treatment expenses, the initial and final reduction rates were both affected significantly by the following management factors: management of medical records, number of beds, number of departments, number of personnel reviewing health insurance, and total number of employees. The management factors significantly affecting both the initial and final reduction rates were higher number of beds for hospitalization expenses and electronic medical record management for outpatient treatment expenses. The environmental factors significantly affecting both the initial and final reduction rates of hospitalization expenses were a highly cooperative work environment, better implementation of indicator management systems, and overtime pay. Better implementation of indicator management system and a committee for handling medical expenses had significant effects on the initial reduction rate for outpatient treatment expenses. A highly cooperative work environment, better implementation of indicator management system, and overtime pay had significant effects on the final reduction rate for outpatient treatment expenses.

A Study of Validity in Tripartite Model of "Attitudes towards Science" using Exploratory and Confirmatory Factor Analyses (탐색적 확인적 요인 분석을 통한 "과학에 대한 태도" 3요소 모델의 타당도 연구)

  • Lee, Kyung-Hoon
    • Journal of The Korean Association For Science Education
    • /
    • v.17 no.4
    • /
    • pp.481-492
    • /
    • 1997
  • The purpose of this study is to construct validity of Tripartite model of "Attitudes towards Science" using Exploratory and Confirmatory Factor Analyses. Exploratory and confirmatory factor analyses are two major approaches to factor analysis. The primary goal of factor analysis is to explain the covariances or correlations between many observed variables by means of relatively few underlying latent variables. In exploratory factor analysis, the number of latent variables is not determined before the analysis, all latent variables typically influence all observed variables, the measurement errors(${\delta}$) are not allowed to correlate, and unidentification of parameters is common. Confirmatory factor analysis requires a detailed and identified initial model. Confirmatory factor analysis techniques allow relations between latent and observed variables that are not possible with traditional, exploratory factor analysis techniques. As a result of exploratory factor analysis, tripartite model of "Attitudes towards Science" being composed of affection, behavioral intention and cognition is empirically identified. But attitude of science career being composed of affection and behavioral intention is identified. In validity test using confirmatory factor analysis, measurement structure of Tripartite model of "Attitudes towards Science" is not correspondent to data set. Because it is concluded that the object of attitudes are not specific.

  • PDF

GHz Bandwidth Characteristics of Rectangular Spiral type Thin Film Inductors (사각 나선형 박막 인덕터의 GHz 대역 특성)

  • Kim, J.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.52-57
    • /
    • 2004
  • In this research, characteristics of air core rectangular spiral type inductors of ㎓ band are numerical analyzed. The basic structure of inductors is a rectangular spiral having 390${\mu}{\textrm}{m}$${\times}$390${\mu}{\textrm}{m}$ size, 5.5 turns, line width of 10 ${\mu}{\textrm}{m}$ and line space of 10 ${\mu}{\textrm}{m}$. Frequency characteristics were simulated up to 10 ㎓. The substrate was modeled as Si, Sapphire, glass and GaAs and the conductor as Cu. The thickness of the conductor was fixed at 2. The number of turns was n.5 to make the input and output terminals to be on the opposite sides. The initial inductance of the basic inductor structure was 13.0 nH, maximum inductance 60.0 nH and resonance frequency 4.25 ㎓. As the dielectric constant of the substrate was increased, the initial inductance varied only slightly, but the resonance frequency decreased considerably. As the number of turns was varied from 1.5 to 9.5, the initial inductance was increased linearly from 2.9 nH to 15.9 nH and, then, saturated at 16.9 nH. The Q factor increased only slightly. The line width and line space of inductors were varied from 5 ${\mu}{\textrm}{m}$ to 20 ${\mu}{\textrm}{m}$, which resulted in the decrease of the initial and maximum inductances. But the resonance frequency was increased. Q factor displayed an increase and a decrease, respectively, when the line width and line space were increased.

Hemophilia B (factor IX deficiency) in a Labrador retriever dog

  • Kim, Jun-Hwan;Noh, Dong-Ho;Song, Ru-Hui;Lee, Da-Mi;Cho, Ho-Seong;Yu, Do-Hyeon;Park, Jin-Ho;Park, Chul
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.191-193
    • /
    • 2011
  • A 3-month-old intact male, Labrador retriever was presented with the history of coagulopathy and anemia. The results of initial screening tests of the hemostatic system yielded a tentative diagnosis of hemophilia. Activated partial thromboplastin time (APTT) was distinctly prolonged (106 seconds) and prothrombin time (PT) was not detected due to markedly prolonged test time. Whole blood transfusions (20 me l/kg body weight) were carried out prior to assays of coagulation factor. After transfusion, the patient recovered well and hemorrhage ceased. Blood samples were assessed for coagulation factor activity. The patient showed markedly low factor IX coagulation activity (5%, reference range: 7~140%) and was diagnosed with hemophilia B. After recovery, the patient was discharged from the hospital. However, 4 months later the patient was re-hospitalized for recurrence of the initial symptoms. The owner did not want to pursue further treatment and the patient died of respiratory distress two days later.

A Study on Confirmation Bias in Early User Experience Stage (초기 사용자 경험 단계의 확증편향에 관한 연구)

  • Lee, Young-Ju
    • Journal of Digital Convergence
    • /
    • v.19 no.1
    • /
    • pp.355-360
    • /
    • 2021
  • In this study, the factors of confirmation bias that may occur in the initial user experience stage were analyzed using a honeycomb model by deriving user experience factors for each factor. In the initial user experience stage, confirmation bias occurs in the impression stage. At the processing stage of memory, sensory memory, working memory, and long-term memory, which stores and retrieves selective memory, were closely related. Confirmation bias was classified into visibility, correlation, memory, clarity, and universality in the usability part, and satisfaction, joy, and dissatisfaction were derived as emotional factors. As a result of the analysis with the honeycomb model, visuality, clarity, universality in the usability factor, and joy in the emotional factor had little effect on the confirmation bias, and satisfaction and dissatisfaction were analyzed as the main factors of the confirmation bias in the correlation, memory and emotional factors. This study is meaningful in that it can be usefully used as a reference material for companies that customize design patterns for the factor of confirmation bias.