• Title/Summary/Keyword: Inhomogeneity test

Search Result 31, Processing Time 0.025 seconds

A Study on the Estimate Real Time Delay Model using BIS Data (버스정보시스템(BIS) 운행데이터를 이용한 실시간 지체시간 산정모형 구축)

  • Lee, Young-Woo;Kwon, Hyuck-Jun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.14-22
    • /
    • 2011
  • This study is to estimate delay time model of signalized intersection by using travel data of Bus Information System. BIS, which applies the advanced information technology to an existing bus system, has been developing and operating in many cities. However, even though some useful traffic informations have been collected from BIS operation, utilization of real-time data to the traffic operation has not been promoted due to the inhomogeneity of modal speeds. Accordingly, in this study, a fundamental research is performed for traffic controls in urban areas and providing a traffic information throughout a methodology for estimating delay time using the data from BIS was developed. This delay time model setting bus travel time excluding service time of a bus stop as explanatory variables was constructed as a regression model, and the coefficient of determination of a linear regression model most highly appeared as 0.826. As a result of performing T-test with field survey values and model estimation values for verifying constructed models statistically, it was analyzed to be statistically significant in a confidence level of 95%.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Tomato (토마토 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Oh, Young-Gon;Choi, Sung-Gil;Hong, Su-Myeong;Kim, Sun-bae;Woo, In-Duk;Kim, Jun-Young;Seo, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.223-233
    • /
    • 2016
  • BACKGROUND: This study was to develop a analytical reference material including twenty pesticides in tomato. To use it for proficiency test, the suitability of homogeneity, storage stability, assigned values and uncertainty for analytical reference material were important.METHODS AND RESULTS: In order to develop a analytical reference material of tomato for multi-residue analysis of pesticides, twenty-pesticides were treated in tomato and the samples were frozen and homogenized. The homogeneity, stability, assigned value and uncertainty were calculated according to the requirements of the KS A ISO Guide 35, KS Q ISO 13528 and EURL-PT protocol. The values of the within-bottle standard variation(swb) and the between-bottle standard variation(sbb) were 0.9~6.5% of assigned value and the uncertainty(u*bb) due to inhomogeneity was also calculated as 0.6~1.9% for all pesticides. This indicated that it was satisfactory to be used as a analytical reference material. The storage stabilities of twenty-pesticides at room temperature and freezing conditions were assessed according to the requirement of the KS Q ISO Guide 35. All pesticides were stable at room temperature (20~30℃) for 8 days and freezing (-20℃) for 23 days.CONCLUSION: The feasibility of analytical reference material for pesticide multi-residue analysis in a tomato matrix was investigated. Homogeneity of within/between-bottle, uncertainty and stabilities at room temperature and freezing condition were satisfactory for a use of proficiency test and quality control. From these results, a analytical reference material would be applicable to monitor the proficiency test of pesticide analysis organizations to improve the reliability and consistency.

Measurement of losses in mirror using cavity ring-down method (공동 광자 감쇠시간 측정 방법을 이용한 반사경의 손실 측정)

  • Shin, Myung-Jin;Cho, Hyun-Ju;Lim, Kyung-Ah;Moon, Young-Kwon;Moon, Gun;Lee, Jae-Cheul
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • We set up a loss measurement apparatus using cavity ring-down method to get the losses in mirror having a small absorption and scattering. The measured errors could be explained by the loss inhomogeneity of the position of the mirror included in the cavity, and we knew that the long~period measurement limit of apparatus is three days, the minimum error limit of Lhe term is 4 ppm, which were gotten by measuring the long-period and short-period decay time in both reference and test cavity. Also we determined the losses m various mirrors fabricated at our laboratory using the apparatus and we found that the losses in mirrors are quite different at their spatial positions. tions.

  • PDF

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

Long-Term Trend of Surface Wind Speed in Korea: Physical and Statistical Homogenizations (한반도 지상 풍속의 장기 추세 추정: 관측 자료의 물리적 및 통계적 보정)

  • Choi, Yeong-Ju;Park, Chang-Hyun;Son, Seok-Woo;Kim, Hye-Jin
    • Atmosphere
    • /
    • v.31 no.5
    • /
    • pp.553-562
    • /
    • 2021
  • The long-term trend of surface wind speed in Korea is estimated by correcting wind measurements at 29 KMA weather stations from 1985 to 2019 with physical and statistical homogenization. The anemometer height changes at each station are first adjusted by applying physical homogenization using the power-law wind profile. The statistical homogenization is then applied to the adjusted data. A standard normal homogeneity test (SNHT) is particularly utilized. Approximately 40% of inhomogeneities detected by the SNHT match with the sea-level-height change of each station, indicating that an SNHT is an effective technique for reconciling data inhomogeneity. The long-term trends are compared with homogenized data. Statistically significant negative trends are observed along the coast, while insignificant trends are dominant inland. The mean trend, averaged over all stations, is -0.03 ± 0.07 m s-1 decade-1. This insignificant trend is due to a trend change across 2001. A decreasing trend of -0.10 m s-1 decade-1 reverses to an increasing trend of 0.03 m s-1 decade-1 from 2001. This trend change is consistent with mid-latitude wind change in the Northern hemisphere, indicating that the long-term trend of surface wind speed in Korea is partly determined by large-scale atmospheric circulation.

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Green-pepper (풋고추 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Choi, Sung-Gil;Oh, Young-Gon;Kwon, Young-Sang;Hong, Su-Myeong;Sung, Mun-Hyun;Lee, Se-Ja;Hwang, Sun-Young;Seo, Jong-Su
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.211-220
    • /
    • 2016
  • This study was to develop the analytical reference material of green-pepper for multi-residue analysis of pesticides. According to the ISO Guide 35, ISO Guide 13528 and EURL-PT protocol, the homogeneity, stability, assigned value and uncertainty were calculated to assess if it was suitable to be used as the proficiency test or quality control. The values of the within-bottle standard variation ($s_{wb}$) and the between-bottle standard variation ($s_{bb}$) were 1.7~3.7% of assigned value according to the requirement of the ISO guide 35. And, the uncertainty ($u^*{_{bb}}$) due to inhomogeneity was 0.8~1.1% for all pesticides. The storage stabilities of ten-pesticides at various conditions were assessed. For all target pesticides, the slop ($b_1$) values were smaller than the corresponding values of $[t_{0.95,n-2}{\times}s(b_1)]$ specified by the ISO guide 35, indicating that there were no statistically significant decreases in the concentration of the target pesticides when the analytical reference material was stored at room temperature ($20{\sim}30^{\circ}C$) for 7 days, freezing ($-20^{\circ}C$) for 30 days and deep freezer ($-80^{\circ}C$. except for bifenthrin, fenpropathrin) for 245 days. For proficiency test by using it developed by Korea Institute of Toxicology, inter-lab test was performed with eight organization performing the residual pesticide analysis. We found that there were some different results among them. Some were assessed as questionable or unacceptable for two pesticides and one organization didn't analyze the six pesticides. From these results, this green-pepper analytical reference material containing ten-pesticides could be used as a tool for the proficiency test to improve the reliability or consistency for pesticide residue's results.

Setting of the range for shear strength of fault cores in Gyeongju and Ulsan using regression analysis (회귀분석을 이용한 경주·울산 지역에 분포하는 단층 핵의 전단강도 범위 설정)

  • Yun, Hyun-Seok;Moon, Seong-Woo;Seo, Yong-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.127-140
    • /
    • 2015
  • A fault is one of the critical factors that may lead to a possible ground collapse occurring in construction site. A fault core, however, possibly acting as a failure plane in whole fault zone, is composed of fractured rock and gouge nonuniformly distributed and thus can be characterized by its wide range of shear strength which is generally acquired by experimental method for stability analysis. In this study, we performed direct shear test and grain size distribution analysis for 62 fault core samples cropped from 12 different spots located in the vicinity of Kyongju and Ulsan, Korea. As a result, the range of shear strength representing the characteristics of fault cores in the study regions is determined with regard to vertical stress using a regression analysis for experiment data. The weight ratio of gravels in the samples is proportional to the shear strength and that of silt and clay is in inverse proportion to the shear strength. For most samples, the coefficient of determination is over 0.7 despite of inhomogeneity of them and consequently we determined the lower limit and upper limit of the shear strength with regard to the weight ratio by setting the confidence interval of 95%.

A Development of 3-D Numeric Model for the Confined Flow and Discharge under Sea Ground (해저 지중 피압유체의 흐름과 양수량 산출에 관한 3차원 수치모형의 개발)

  • Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.6
    • /
    • pp.387-396
    • /
    • 2010
  • A 3-D numeric model for the confined transient flow under sea ground have been developed. This is FDM model using Gauss-Seidel SOR (successive over-relaxation). This model shows the similar head distribution pattern to Theis analytic solution and MODFLOW simulation. The input flowrate to the aquifer and discharge of well have been compared. And it have been found that mass balance is influenced by the weight factor ${\alpha}$, i.e. fullyimplicit method (${\alpha}$=1) shows 5% error, but when ${\alpha}$ becomes to 0.5(Crank and Nicolson method) the mass balance becomes worse and the model result diverges. And the convergency of the model is not much different when $\lambda$ (over-relaxation factor)=0.8~1.5, but when $\lambda$>1.5, the model result diverges. The test-run shows that the well discharge becomes smaller when another well is near. This model can cover the isotropy$(Kx{\neq}Ky{\neq}Kz)$ and inhomogeneity, and can be used for the selection of well site, discharge calculation, and head prediction in case of the artificial recharge etc.

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF