• 제목/요약/키워드: Infrared thermometer

검색결과 70건 처리시간 0.024초

한의표준임상진료지침 개발을 위한 수족냉증에 대한 한의사의 인식과 치료현황 (A Survey on Korean Medicine Doctors' Recognition and Treatment for Developing Korean Medicine Clinical Practice Guideline of Coldness of Hands and Feet)

  • 이동녕;김형준;유준상
    • 대한한방부인과학회지
    • /
    • 제30권3호
    • /
    • pp.92-116
    • /
    • 2017
  • Objectives: The purpose of this study were to researched a Korean medicine doctors' recognition about coldness of hands and feet, and developing of korean medicine clinical practice guidelines (CPG) for coldness of hands and feet. Methods: We conducted a questionnaire survey targeting 399 Korean medicine doctors belonging to the Association of Korean Medicine by e-mail and analyzed the answers. Results: 1. 86.86% of the respondents agreed about the necessity of CPG for coldness of hands and feet. 2. 84.2% of respondents wanted coding of Korean Standard Classification of Diseases (KCD) on coldness of hands and feet. 3. To diagnosis a coldness of hands and feet, the respondents used a Subjective symptoms (98.5%), Infrared thermographic imaging device (DITI) (26.32%) Heart rate variablity test (HRV) (17.04%), Thermometer (9.77%), Cold stress test (2.76%) 4. Causing of coldness of hands and feet, the respondents considered a constitution or heredity (84.71%), stress (73.66%), lack of exercise (64.91%), irregular eating habits (51.63%), Cold meals (32.83%), depression (31.33%), etc. 5. Treating coldness of hands and feet, the respondents used a herbal medicine (66.85%), acupuncture (70.7%) Pharmacopuncture (23.85%) and moxibustion (60.08%) for $10.91{\pm}8.03week$. Conclusions: We researched a Korean Medicine doctors' recognition of CPG, clinical diagnosis, treatment on a coldness of hands and feet, and policy they required.

흑구온도를 이용한 천궁 엽온 예측 모델 개발 (Developing a Model for Estimating Leaf Temperature of Cnidium officinale Makino Based on Black Globe Temperature)

  • 서영진;남효훈;장원철;이부용
    • 한국약용작물학회지
    • /
    • 제26권6호
    • /
    • pp.447-454
    • /
    • 2018
  • Background: The leaf temperature ($T_{LEAF}$) is one of the most important physical parameters governing water and carbon flux, including evapotranspiration, photosynthesis and respiration. Cnidium officinale is one of the important folk medicines for counteracting a variety of diseases, and is particularly used as a traditional medicinal crop in the treatment of female genital inflammatory diseases. In this study, we developed a model to estimate $T_{Leaf}$ of Cnidium officinale Makino based on black globe temperature ($T_{BGT}$). Methods and Results: This study was performed from April to July 2018 in field characterized by a valley and alluvial fan topography. Databases of $T_{LEAF}$ were curated by infrared thermometry, along with meteorological instruments, including a thermometer, a pyranometer, and an anemometer. Linear regression analysis and Student's t-test were performed to evaluate the performance of the model and significance of the parameters. The correlation coefficient between observed $T_{LEAF}$ and calculated $T_{BGT}$ obtained using an equation, developed to predict $T_{LEAF}$ based on $T_{BGT}$ was very high ($r^2=0.9500$, p < 0.0001). There was a positive relationship between $T_{BGT}$ and solar radiation ($r^2=0.8556$, p < 0.0001), but a negative relationship between $T_{BGT}$ and wind speed ($r^2=0.9707$, p < 0.0001). These results imply that heat exchange in leaves seems to be mainly controlled by solar radiation and wind speed. The correlation coefficient between actual and estimated $T_{BGT}$ was 0.9710 (p < 0.0001). Conclusions: The developed model can be used to accurately estimate the $T_{Leaf}$ of Cnidium officinale Makino and has the potential to become a practical alternative to assessing cold and heat stress.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • 제52권5호
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

스마트폰 사용 시간에 따른 안구온도 변화와 눈의 피로도 분석 (Analysis of Eye Fatigue and Change of Eye Temperature according to Smartphone Usage Time)

  • 한선희;김봉환;김형수;정재완;박지애;김치환
    • 한국임상보건과학회지
    • /
    • 제10권2호
    • /
    • pp.1594-1599
    • /
    • 2022
  • Purpose. To investigate the relationship between changes in eye temperature and eye fatigue according to smartphone usage time. Methods. 15 adults in their 20s were asked to watch a smartphone, and the ocular surface temperature was measured 5 times each using a non-contact infrared thermometer every 10 minutes, and the change was observed. Result. The ocular surface temperature was 36.40℃ at the center of the cornea before watching the smartphone, but increased by 0.19℃ to 36.59℃ after watching the smartphone (SD 36.50±0.10). In addition, in the case of the sclera, it was found that the increase was 0.1℃ from 36.48℃ before viewing to 36.58℃ after viewing (SD 36.53±0.05). Conclusion. It was found that there is a close relationship between smartphone use and changes in eye temperature. In the future, it is thought that the ocular surface temperature can be used as basic data to objectively evaluate eye fatigue.

한의 복진 정량화 연구 - 기능성 소화불량 환자의 복냉 진단을 중심으로 - (Study on the Possibility of Quantitative Measurement of Abdominal Examinations in Korean Medicine - A Focus on Diagnosis of Abdominal Coldness in Functional Dyspepsia Patients -)

  • 이재홍;조수호;고석재;김진성;박재우
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.495-510
    • /
    • 2018
  • Objective: This study was designed to investigate the possibility of quantification of the diagnosis of abdominal coldness (AC) in patients with functional dyspepsia (FD). Methods: Forty-four patients with FD were enrolled in this study. Three Korean medicine doctors each randomly examined all abdomens. Diagnosis of AC was made by consensus of at least two of the doctors. Body temperature (oral by digital oral thermometer) and skin temperature (by digital infrared thermal imaging [DITI]) were measured, followed by administration of the Cold and Heat questionnaire (CHQ) and the Instrument of Pattern Identification for Functional Dyspepsia (IPIFD). Results: Of the 44 patients with FD, 22 were assigned to the AC group and 22 to the non-AC group. The concordance rate of diagnosis among the three doctors was 63.6% (28/44), with a ${\kappa}$ of 0.504, indicating means moderate agreement). Neither the oral nor the skin temperatures showed statistically significant differences between the AC and non-AC groups. However, the CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD were higher in AC group and showed statistically significant differences (p=0.010 and 0.009). Conclusions: This is the first study conducting quantitative measurements of abdominal coldness in patients with FD. Although oral and skin temperature showed no statistical significance between AC and non-AC groups, the concordance rate of diagnosis of AC among the three Korean Medicine doctors was moderate. The CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD also suggest that diagnosis of AC is relevant to cold and heat patterns, and these questionnaires could be utilized as supportive data for the diagnosis of AC. Further studies should be conducted for the purpose of quantifying and standardizing abdominal examinations in Korean Medicine.

Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과 (Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser)

  • 김여원;박호원;이주현;서현우;이시영
    • 대한소아치과학회지
    • /
    • 제47권4호
    • /
    • pp.446-453
    • /
    • 2020
  • 이 연구의 목적은 Indocyanine Green(ICG)과 근적외선(Near Infrared, NIR) 다이오드 레이저가 Streptococcus mutans 세균막에 미치는 효과를 ICG 용액의 농도에 따라 평가하는 것이었다. Hydroxyapatite disk에 S. mutans 세균막을 형성하여 멸균 증류수에 용해시킨 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL의 ICG 용액과 300 mW의 출력, 808 nm의 파장을 가지는 NIR 다이오드 레이저를 적용하였다. 모든 표본은 공초점 레이저 주사 현미경(Confocal Laser Scanning Microscopy, CLSM)을 이용하여 관찰하였다. 또한 1채널 열전대 온도계와 Thermocouple을 이용하여 광조사 시에 ICG 용액의 농도에 따른 세균막 표면의 온도 변화를 함께 측정하였다. 대조군과 비교 시에 ICG 용액 만을 도포한 군에서는 3.0, 4.0, 5.0 mg/mL의 농도에서, 그리고 ICG 용액의 도포와 광조사를 함께 시행한 군에서는 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL의 농도에서 통계적으로 유의한 세균 수의 감소가 관찰되었다. 용액의 농도에 따른 온도 증가량은 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL의 ICG 용액에서 각각 9.53℃, 10.43℃, 11.4℃, 12.1℃, 12.67℃, 13.63℃ 이었다. 즉, ICG 용액의 농도가 3.0 mg/mL이면 그 자체로도 S. mutans 세균막을 억제할 수는 있으나, NIR 다이오드 레이저를 함께 사용하면 주변 조직 손상의 우려 없이 더 효율적인 항균 작용을 나타낼 수 있다. 따라서, 이번 연구는 새로운 치아 우식증 예방법으로 ICG와 NIR 다이오드 레이저의 임상적 적용의 가능성을 제시한다.

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

표면개질된 초고분자량 폴리에틸렌 분말의 표면과 화학적 특성 및 이를 함유하는 상온 경화용 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성 I. 메틸 메타크릴레이트/자일렌 함량에 따른 초고분자량 폴리에틸렌의 표면 개질 효과 (Surface and Chemical Properties of Surface-modified UHMWPE Powder and Mechanical Properties of Self Curing PMMA Bone Cement Containing UHMWPE Powder I. Effect of MMA/Xylene Contents on Surface Modification of UHMWPE)

  • 양대혁;윤관희;김순희;이종문;강길선
    • 폴리머
    • /
    • 제28권1호
    • /
    • pp.77-85
    • /
    • 2004
  • 초고분자량 폴리에틸렌은 우수한 기계적 특성과 생체 적합성으로 인해 생체 재료 분야에서 널리 이용되어 왔다. 그러나, 다른 생체 고분자 재료와의 접착 시, 초고분자량 폴리에틸렌 분말의 표면 불활성으로 인해 접착력이 현저히 감소한다. 본 연구에서는 초고분자량 폴리에틸렌 분말을 첨가함으로써 상온 경화형 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성 및 열적 특성을 향상시키기 위해 메틸 메타크릴레이트와 자일렌의 혼합 용액으로 초고분자량 폴리에틸렌 분말의 표면 개질을 시도하였다. 개질 후, 표면 처리된 초고분자량 폴리에틸렌 분말은 적외선 분광기, 주사전자 현미경, 인장압축 시험기, 및 디지털 온도계로 특성을 결정하였다. 메틸 메타크릴레이트와 자일렌의 함량을 달리하여 표면 개질된 초고분자량 폴리에틸렌 분말을 함유한 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성을 측정해 본 결과, 메틸 메타크릴레이트/자일렌을 1 : 1 (부피 비율)로 표면 개질한 초고분자량 폴리에틸렌 분말을 첨가시킨 새로운 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 강도가 최대였으며, 중합 열은 103 $^{\circ}C$에서 58∼73 $^{\circ}C$로 감소함을 확인하였다. 또한, 초고분자량 폴리에틸렌 분말의 표면 개질방법의 메카니즘을 제안하였다.

질소결핍 오이의 비파괴 진단법 비교 (Comparison of Non-desructive Method to Detect Nitrogen Deficient Cucumber)

  • 성제훈;서상룡;류육성;정갑채
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.539-546
    • /
    • 1999
  • 오이를 공시재료로 하여, 생육중인 식물 잎으로부터 비교적 신속하게 생체정보 수집이 가능한 비파괴 계측기인 엽록소 측정기, 엽록소 형광측정기, 적외선 엽온측정기, 반사형 분광분석기를 이용하여 질소 결핍장해 오이의 조기 진단 가능성 여부와 그 유용한 정도를 파악하기 위하여 수행한 연구의 주요 결과는 다음과 같다. 1) 엽록소 측정기의 측정값으로서 질소 결핍장해 오이의 진단은 엽록소 함량 45 SPAD 이하 여부로서 판단할 수 있고, 이에 의한 질소 결핍 장해의 진단은 장해 발생 후 빠르면 3일 정도면 적중율 95%수준의 장해 진단이 가능하고 7∼10일 후엔 높은 정확도의 진단이 가능함을 알 수 있었다. 2) 엽록소 형광 측정에 의한 질소 결핍장해 오이의 진단은 장해 발생 후 빠르면 5일째부터 적중률 95%수준의 장해 진단이 가능하며, 이에 의한 오이의 질소 결핍장해 진단은 엽록소 함량 측정에 의한 진단보다는 우수하지 못하다. 그리고 대기-엽온차에 의해 질소 결핍장해 오이의 진단은 불가능한 것으로 판단되었다. 3) 분광분석기의 흡광도 분석에 의한 질소 결핍 진단의 민감 파장대는 562∼564 nm, 700∼724 nm, 1,886∼1,894 nm으로 분석되었다. 이러한 영역의 파장에 의한 질소 결핍장해 오이의 진단은 장해 발생후 3∼4일째부터 적중을 95%수준의 진단이 가능하며, 진단의 정확도는 본 연구에서 사용한 4가지 측정기 중 가장 우수하였다.

  • PDF

티타늄 황삭가공에 있어서 절삭공구의 마모 특성에 관한 연구 (A Study on Wear Characteristics of Cutting Tools in a Titanium Roughing Cut Machining)

  • 배명환;정화;박형렬
    • 한국자동차공학회논문집
    • /
    • 제24권1호
    • /
    • pp.67-73
    • /
    • 2016
  • The application of titanium has been gradually rising because the utilizing ranges for low weight and high strength are rapidly increased by the need for improving the fuel economy in production industries such as the aviation and automotive in recent. The purpose in this study is to investigate the appropriate cutting conditions on the life of flat and round end mills by measuring the maximum cutting temperature relative to the machining time, and calculating the wear rates of cutting tool with the spindle speed and feed rate of vertical machining center as a parameter in the titanium roughing cut machining which is widely used in critical parts of aircraft, cars, etc. When the wetted roughing cut machining of titanium with a soluble cutting oil is conducted by the flat and round end mills, the maximum cutting temperatures for a variety of spindle speed and feed rate are measured at ten-minute intervals during 60 minutes by an infrared thermometer, and the wear rates of cutting tool are calculated by the weight ratios based on tool wear before and after the experiment. It is found that the maximum cutting temperature and the wear rates of cutting tool are raised as the cutting amount per tool edge is increased with the rise of feed rate, in this experimental range, and as the frictional area due to the rise of contacting friction numbers between tool and specimen is increased with the rises of cutting time and spindle speed. In addition, the increasing rate of maximum cutting temperature in the flat and round end mills are the highest for the cutting time from 50 to 60 minutes, and the wear rate of cutting tool in the flat end mill is 1.14 to 1.55 times higher than that in the round end mill for all experimental conditions.