Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model |
Choi, Yoon-Sil
(Department of Periodontology, Veterans Health Service Medical Center)
Oh, Jae-Woon (Department of Periodontology, Veterans Health Service Medical Center) Lee, Young (Veterans Medical Research Institute, Veterans Health Service Medical Center) Lee, Dong-Woon (Department of Periodontology, Veterans Health Service Medical Center) |
1 | Tehemar SH. Factors affecting heat generation during implant site preparation: a review of biologic observations and future considerations. Int J Oral Maxillofac Implants 1999;14:127-36. |
2 | Davidson SR, James DF. Measurement of thermal conductivity of bovine cortical bone. Med Eng Phys 2000;22:741-7. DOI |
3 | Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Int J Oral Maxillofac Implants 2004;19:335-49. |
4 | Scarano A, Lorusso F, Noumbissi S. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with steel vs. zirconia implant drill. J Clin Med 2020;9:148. DOI |
5 | Norton MR, Gamble C. Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res 2001;12:79-84. DOI |
6 | Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implants Res 2009;20:294-8. DOI |
7 | Augustin G, Davila S, Udilljak T, Staroveski T, Brezak D, Babic S. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill. Int Orthop 2012;36:1449-56. DOI |
8 | Scherer U, Stoetzer M, Ruecker M, Gellrich NC, von See C. Template-guided vs. non-guided drilling in site preparation of dental implants. Clin Oral Investig 2015;19:1339-46. DOI |
9 | Shahlaie M, Gantes B, Schulz E, Riggs M, Crigger M. Bone density assessments of dental implant sites: 1. Quantitative computed tomography. Int J Oral Maxillofac Implants 2003;18:224-31. |
10 | Mohlhenrich SC, Abouridouane M, Heussen N, Modabber A, Klocke F, Holzle F. Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study. Oral Maxillofac Surg 2016;20:135-42. DOI |
11 | Gehrke SA, Bettach R, Cayron B, Boukhris G, Dedavid BA, Frutos JC. Development of a new drill design to improve the temperature control during the osteotomy for dental implants: a comparative in vitro analysis. Biology (Basel) 2020;9:9. |
12 | Zhou M, Zhou H, Li SY, Zhu YB, Geng YM. Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study. J Stomatol Oral Maxillofac Surg 2021;122:343-8. DOI |
13 | Oh HJ, Wikesjo UM, Kang HS, Ku Y, Eom TG, Koo KT. Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Clin Oral Implants Res 2011;22:722-6. DOI |
14 | Rubayo DD, Phasuk K, Vickery JM, Morton D, Lin WS. Influences of build angle on the accuracy, printing time, and material consumption of additively manufactured surgical templates. J Prosthet Dent 2021;126:658-63. DOI |
15 | Markovic A, Lazic Z, Misic T, Scepanovic M, Todorovic A, Thakare K, et al. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs. Vojnosanit Pregl 2016;73:744-50. DOI |
16 | Stocchero M, Sivolella S, Brunello G, Zoppello A, Cavallin F, Biasetto L. Bone temperature variation using a 3D-printed surgical guide with internal irrigation. Appl Sci 2021;11:2588. DOI |
17 | Kondo S, Okada Y, Iseki H, Hori T, Takakura K, Kobayashi A, et al. Thermological study of drilling bone tissue with a high-speed drill. Neurosurgery 2000;46:1162-8. DOI |
18 | Isler SC, Cansiz E, Tanyel C, Soluk M, Selvi F, Cebi Z. The effect of irrigation temperature on bone healing. Int J Med Sci 2011;8:704-8. DOI |
19 | Laurito D, Lamazza L, Garreffa G, De Biase A. An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone. Ann Ist Super Sanita 2010;46:405-10. |
20 | Smith PN, Palenik CJ, Blanchard SB. Microbial contamination and the sterilization/disinfection of surgical guides used in the placement of endosteal implants. Int J Oral Maxillofac Implants 2011.26:274-81. |
21 | Oh KC, Shim JS, Park JM. In vitro comparison between metal sleeve-free and metal sleeve-incorporated 3D-printed computer-assisted implant surgical guides. Materials (Basel) 2021;14:615. DOI |
22 | Boa K, Barrak I, Varga E Jr, Joob-Fancsaly A, Varga E, Piffko J. Intraosseous generation of heat during guided surgical drilling: an ex vivo study of the effect of the temperature of the irrigating fluid. Br J Oral Maxillofac Surg 2016;54:904-8. DOI |
23 | Orgev A, Gonzaga L, Martin W, Morton D, Lin WS. Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy. J Prosthet Dent 2021;126:164-6. DOI |
24 | Eriksson A, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital-microscopic description of heat effects. Int J Oral Surg 1982;11:115-21. DOI |
25 | Ashry A, Elattar MS, Elsamni OA, Soliman IS. Effect of guiding sleeve design on intraosseous heat generation during implant site preparation (in vitro study). J Prosthodont 2021;31:147-54. |
26 | Alhroob KH, Alsabbagh MM, Alsabbagh AY. Effect of the use of a surgical guide on heat generation during implant placement: a comparative in vitro study. Dent Med Probl 2021;58:55-9. DOI |
27 | Liu YF, Wu JL, Zhang JX, Peng W, Liao WQ. Numerical and experimental analyses on the temperature distribution in the dental implant preparation area when using a surgical guide. J Prosthodont 2018;27:42-51. DOI |
28 | dos Santos PL, Queiroz TP, Margonar R, de Souza Carvalho AC, Betoni W Jr, Rezende RR, et al. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: guided surgery and classic drilling procedure. Int J Oral Maxillofac Implants 2014;29:51-8. DOI |
29 | Smitkarn P, Subbalekha K, Mattheos N, Pimkhaokham A. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J Clin Periodontol 2019;46:949-57. DOI |
30 | D'Souza KM, Aras MA. Types of implant surgical guides in dentistry: a review. J Oral Implantol 2012;38:643-52. DOI |
31 | Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-8. DOI |
32 | Salimov F, Ozcan M, Ucak Turer O, Haytac CM. The effects of repeated usage of implant drills on cortical bone temperature, primary/secondary stability and bone healing: a preclinical in vivo micro-CT study. Clin Oral Implants Res 2020;31:687-93. DOI |
33 | Lajolo C, Valente NA, Romandini WG, Petruzzi M, Verdugo F, D'Addona A. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation. J Periodontol 2018;89:661-8. DOI |