DOI QR코드

DOI QR Code

Analysis of Eye Fatigue and Change of Eye Temperature according to Smartphone Usage Time

스마트폰 사용 시간에 따른 안구온도 변화와 눈의 피로도 분석

  • Sun-Hee, Han (Dept. of Optometry, Choonhae College of Health Sciences) ;
  • Bong-Hwan, Kim (Dept. of Optometry, Choonhae College of Health Sciences) ;
  • Hyeong-Su, Kim (Dept. of Optometry, Choonhae College of Health Sciences) ;
  • Jae-Wan, Jeong (Dept. of Optometry, Choonhae College of Health Sciences) ;
  • Ji-Ae, Park (Dept. of Optometry, Choonhae College of Health Sciences) ;
  • Chi-Hwan, Kim (Dept. of Optometry, Choonhae College of Health Sciences)
  • 한선희 (춘해보건대학교 안경광학과) ;
  • 김봉환 (춘해보건대학교 안경광학과) ;
  • 김형수 (춘해보건대학교 안경광학과) ;
  • 정재완 (춘해보건대학교 안경광학과) ;
  • 박지애 (춘해보건대학교 안경광학과) ;
  • 김치환 (춘해보건대학교 안경광학과)
  • Received : 2022.10.11
  • Accepted : 2022.11.10
  • Published : 2022.12.31

Abstract

Purpose. To investigate the relationship between changes in eye temperature and eye fatigue according to smartphone usage time. Methods. 15 adults in their 20s were asked to watch a smartphone, and the ocular surface temperature was measured 5 times each using a non-contact infrared thermometer every 10 minutes, and the change was observed. Result. The ocular surface temperature was 36.40℃ at the center of the cornea before watching the smartphone, but increased by 0.19℃ to 36.59℃ after watching the smartphone (SD 36.50±0.10). In addition, in the case of the sclera, it was found that the increase was 0.1℃ from 36.48℃ before viewing to 36.58℃ after viewing (SD 36.53±0.05). Conclusion. It was found that there is a close relationship between smartphone use and changes in eye temperature. In the future, it is thought that the ocular surface temperature can be used as basic data to objectively evaluate eye fatigue.

Keywords

Acknowledgement

이 논문은 2022년도 춘해보건대학교 학술연구비 지원에 의한 것임.

References

  1. MSIT(Ministry of Science and ICT, Korea). 2017 Result of research on dependence on smartphpne, 2018.
  2. Scheiman M. Accommodative and binocular vision disorders associated with video display terminals: diagnosis and management issues. J Am Optom Assoc. 1996;67:531-539.
  3. Choi YH, Kim EY Kim. A Study on the preventive effect of smartphone addiction prevention education program for smartphone addiction of parents and infants. J Korean Humanities and Social science. 2020;11(6):2691-2705.
  4. Yu SH, CHO SH, Kim SS, et al. The Relationship between the use of smartphone and the physical and psychological symptoms of adult - focused on gwangju metropolitan city. J Korean Aging Friendly Industry Association. 2018;10(2)75-81.
  5. Thompson WD. Eye problems and visual display terminals-the facts and the fallacies. Ophthamic Physiol Opt. 1998;18(2):111-119.
  6. Schlote T, Kadner G, Freudenthaler N. Marked reduction and distinct patterns of eye blinking in patients with moderately dry eye during video display termonal use. Graefes Arch Clin Exp Opthalmol. 2004;242:306-312. https://doi.org/10.1007/s00417-003-0845-z
  7. Agarwal S, Goel D, Sharma A. Evaluation of the factors which contribute to the ocular complaints in the computerusers. J Clin Diagn Res. 2013;7(2)331-335.
  8. Yaginuma Y, Yamada H, Nagai H. Study of the relationship between lacrimation and blink in VDT work, Ergonomics. 1990;33(6)799-808. https://doi.org/10.1080/00140139008927186
  9. Glassi F, Giambene B, Corvi A, Falaschi G. Evaluation of ocular surface temperature and retrobulbar haemodynamics by infrared thermography and colour Doppler imaging in patients with glaucoma. Br J Ophthalmol. 2007;91:878-881. https://doi.org/10.1136/bjo.2007.114397
  10. Sodi A, Giambene B, Falaschi G, et al. Ocular surface temperature in central retinal vein occlusion: preliminary data. Eur J Ophthalmol. 2007;17:755-759. https://doi.org/10.1177/112067210701700511
  11. Sodi A, Giambene B, Miranda P, et al. Ocular surface temperature in diabetic retinopathy: a pilot study by infrared thermography. Eur J Ophthalmol. 2009;19:1004-1008. https://doi.org/10.1177/112067210901900617
  12. Kim JH, Jeong JH, Ha HS, et al. Relationship between the ocular surface temperature and the nasal predominance in pterygium. J Korean Ophthalmol Soc. 2008;49(5):732-736. https://doi.org/10.3341/jkos.2008.49.5.732
  13. Kwon JK, Kang SY, Kim KH, et al. The Ocular fatigue of watching three-dimensional(3D) images. J Korean Ophthalmol Soc. 2012;53(7):941-946. https://doi.org/10.3341/jkos.2012.53.7.941
  14. Suh YW, Kim KH, Kang SY, et al. The objective methods to evaluate ocular fatigue associated with computer work. J Korean Ophthalmol Soc. 2010;51(10):1327-1332.