The Transactions of The Korean Institute of Electrical Engineers
/
v.59
no.3
/
pp.609-613
/
2010
In this paper, we optimized and simulated the heatsink of 75W LED module for street lighting and evaluated the optical properties with the manufactured heatsink. the structure of LED package make simple as chip and heatslug and thermal flow is analyzed by using the FEM(Finite Element Method) with CFdesign V10. Also, we measured the temperature of heatsink and evaluated the optical properties with infrared thermal image camera and integrated sphere system for luminous flux in $1\;[m^3]$ box. As results, Heatsink optimized in 3 mm pin thickness, 6 mm base thickness and 16 number of pin count by using Heatsink-designer and got the results which is the temperature of $47.37\;[^{\circ}C]$ and thermal resistance of $0.48407\;[W/^{\circ}C]$. In thermal flow simulation, the temperature of heatsink decreased from $51.54\;[^{\circ}C]$ to $51.51\;[^{\circ}C]$ and the temperature of heatsink by the time in real measurement decreased from $47.03\;[^{\circ}C]$ to $46.87\;[^{\circ}C]$. Moreover, we improve 0.68 % in the decreased ratio of the luminous flux.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.24
no.4
/
pp.43-49
/
2010
Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. The increase of voltage and current and thermal generation are extremely hard on the life of condenser. Current will be increased, provided that voltage and frequency of condenser increase also. The increase of voltage and frequency justly extends thermal generation. Both act on insulation stress and can afford to premature fault In this paper, we measured thermal distribution of condenser with infrared rays camera in case of variance of voltage and frequency. We were assured that the increase of voltage and frequency produces high heat and exceedingly shortens the life of condenser.
We constructed an unbiased asteroid catalog from the mid-infrared part of the All-Sky Survey with the Infrared Camera (IRC) on board AKARI. About 20% of the point source events recorded in the IRC All-Sky Survey observations were not used for the IRC Point Source Catalog in its production process because of a lack of multiple detection by position. Asteroids, which are moving objects on the celestial sphere, are included in these "residual events" We identified asteroids out of the residual events by matching them with the positions of known asteroids. For the identified asteroids, we calculated the size and albedo based on the Standard Thermal Model. Finally we had a new brand of asteroid catalog, which contains 5,120 objects, about twice as many as the IRAS asteroid catalog.
The structural development of air-water bubble plumes has been measured under different condition on air flow rate in a cylindrical bath. The time-averaged structure of plumes has been measured with an oscilloscope and an electro-conductivity probe. The temperature of bubbles was also obtained by a thermal-infrared camera. Gas volume fraction and bubble frequency were high since bubbles concentrated on the nozzle. In general, their axial and radial values tended to decrease with increasing distance. Bubble temperature reached water temperature within a short time. The present study showed that thermal equilibrium between bubbles and water was completed before bubbles flow became stable.
Kim, J.T.;Kim, J.H.;Koo, J.Y.;Yoon, J.H.;Ham, G.H.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2001.05c
/
pp.186-188
/
2001
In this study, the correlation between leakage currents and temperature rise was investigated for the more accurate diagnosis of bad insulator by use of the infrared camera. For the purpose, leakage currents and thermal images were measured for the artificially aged insulators using salt fog. From the results, it is concluded as follows ; in case of artificially aged insulators, the leakage. current was decreased with the duration of voltage application and was largely affected by humidity, which seems due to ionic conduction. Also, the correlation between temperature rise and leakage current was appeared to be quite linear, although it showed below linearity at large leakage current.
The Multi-purpose InfraRed Imaging System (MIRIS) is the main payload of Science and Technology Satellite 3 (STSAT-3), which was launched onboard Dnepr rocket from Russian Yasny Launch Base in November 2013. The MIRIS is an infrared (IR) camera, and the telescope has to be cooled down to below 200K in order to reduce thermal background noise. For the effective cooling and low-power consumption, we applied passive cooling method to the thermal design of the MIRIS. We also conducted thermal analysis and tested for the passive cooling before the launch of STSAT-3. After the launch, we have received State-of-Health (SOH) data from the satellite on orbit, including temperature monitoring results. It is important that the temperature of the telescope was shown to be cooled down to below 200K. In this paper, we present both the temperature data of the MIRIS on orbit and the thermal analysis results in the laboratory. We also compare these results and discuss the verification of the passive cooling.
Laser cartilage reshaping(LCR) is a promising method for reshaping cartilage by using laser irradiation to maintain permanently modifies its shape. However this method has not been fully understood due to the limited scientific researches. The purpose of this study is to analyze optical and thermal characteristics of cartilage during laser irradiation. After analyzing Monte Carlo simulation for the comparison of laser fluence distributions with different laser wavelengths the characterization of the spectral changes during Nd:YAG laser(${\lambda}$ = 1444 nm) irradiation was investigated in the ranges of 900-1700 nm with double integrating spheres. The surface temperature distribution changes during laser irradiation were investigated with an infrared camera. The quantitative measurements of optical and thermal characteristics in cartilage after laser irradiation were correlated with the transition of water flux(from bound to free water) and this study may be useful for better understanding of biophysical transformation phenomena in cartilage after laser heating.
Satellite's infrared detector shall be calibrated under thermal vacuum environment using a reference black body before a launch. The full aperture black body (FABB) as an infrared calibration reference shall be composed of vacuum compatible materials and temperature controlled from $-40^{\circ}C$ to $+40^{\circ}C$ with emissivity higher than 0.95. The temperature homogeneity over the central 80 % area of the FABB front surface shall be better than 2 K. The FABB designed by thermal and flow analysis was $1m{\times}1m{\times}8mm$ copper plate on which black painted aluminum honeycomb core was attached. Copper tubes were welded on the opposite side of the honeycomb core to allow temperature regulated gaseous nitrogen to flow through them. By the FABB validation test, the temperature homogeneity was observed around 1 K using 20 PT100 sensors and modified COTS infrared camera. The emissivity value was 0.975 at $40^{\circ}C$ under atmospheric pressure.
In this paper, we investigate the thermal response of skin tissue to high-intensity focused ultrasound (HIFU) by means of infrared (IR) thermal imaging. For skin tightening, a 7-MHz ultrasound transducer is used to induce irreversible tissue coagulation in porcine skin. An IR camera is employed to monitor spatiotemporal changes of the temperature in the tissue. The maximum temperature in the tissue increased linearly with applied energy, up to $90^{\circ}C$. The extent of irreversible tissue coagulation (up to 3.2 mm in width) corresponds well to the spatial distribution of the temperature during HIFU sonication. Histological analysis confirms that the temperature beyond the coagulation threshold (${\sim}65^{\circ}C$) delineates the margin of collagen denaturation in the tissue. IR thermal imaging can be a feasible method for quantifying the degree of thermal coagulation in HIFU-induced skin treatment.
Journal of Satellite, Information and Communications
/
v.8
no.4
/
pp.100-104
/
2013
In this paper, we present an optimal threshold setting method for flame detection of infrared thermal image. Conventional infrared flame detection methods used fixed intensity threshold to segment candidate flame regions and further processing is performed to decide correct flame detection. So flame region segmentation step using the threshold is important processing for fire detection algorithm. The threshold should be change in input image depends on camera types and operation conditions. We have analyzed the conventional thresholds composed of fixed-intensity, average, standard deviation, maximum value. Finally, we extracted that the optimal threshold value is more than summation of average and standard deviation, and less than maximum value. it will be enhance flame detection rate than conventional fixed-threshold method.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.