• Title/Summary/Keyword: Infrared Thermometer

Search Result 70, Processing Time 0.027 seconds

A Survey on Korean Medicine Doctors' Recognition and Treatment for Developing Korean Medicine Clinical Practice Guideline of Coldness of Hands and Feet (한의표준임상진료지침 개발을 위한 수족냉증에 대한 한의사의 인식과 치료현황)

  • Lee, Dong-Nyung;Kim, Hyung-Jun;Yu, Jun-Sang
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.3
    • /
    • pp.92-116
    • /
    • 2017
  • Objectives: The purpose of this study were to researched a Korean medicine doctors' recognition about coldness of hands and feet, and developing of korean medicine clinical practice guidelines (CPG) for coldness of hands and feet. Methods: We conducted a questionnaire survey targeting 399 Korean medicine doctors belonging to the Association of Korean Medicine by e-mail and analyzed the answers. Results: 1. 86.86% of the respondents agreed about the necessity of CPG for coldness of hands and feet. 2. 84.2% of respondents wanted coding of Korean Standard Classification of Diseases (KCD) on coldness of hands and feet. 3. To diagnosis a coldness of hands and feet, the respondents used a Subjective symptoms (98.5%), Infrared thermographic imaging device (DITI) (26.32%) Heart rate variablity test (HRV) (17.04%), Thermometer (9.77%), Cold stress test (2.76%) 4. Causing of coldness of hands and feet, the respondents considered a constitution or heredity (84.71%), stress (73.66%), lack of exercise (64.91%), irregular eating habits (51.63%), Cold meals (32.83%), depression (31.33%), etc. 5. Treating coldness of hands and feet, the respondents used a herbal medicine (66.85%), acupuncture (70.7%) Pharmacopuncture (23.85%) and moxibustion (60.08%) for $10.91{\pm}8.03week$. Conclusions: We researched a Korean Medicine doctors' recognition of CPG, clinical diagnosis, treatment on a coldness of hands and feet, and policy they required.

Developing a Model for Estimating Leaf Temperature of Cnidium officinale Makino Based on Black Globe Temperature (흑구온도를 이용한 천궁 엽온 예측 모델 개발)

  • Seo, Young Jin;Nam, Hyo Hoon;Jang, Won Cheol;Lee, Bu Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.6
    • /
    • pp.447-454
    • /
    • 2018
  • Background: The leaf temperature ($T_{LEAF}$) is one of the most important physical parameters governing water and carbon flux, including evapotranspiration, photosynthesis and respiration. Cnidium officinale is one of the important folk medicines for counteracting a variety of diseases, and is particularly used as a traditional medicinal crop in the treatment of female genital inflammatory diseases. In this study, we developed a model to estimate $T_{Leaf}$ of Cnidium officinale Makino based on black globe temperature ($T_{BGT}$). Methods and Results: This study was performed from April to July 2018 in field characterized by a valley and alluvial fan topography. Databases of $T_{LEAF}$ were curated by infrared thermometry, along with meteorological instruments, including a thermometer, a pyranometer, and an anemometer. Linear regression analysis and Student's t-test were performed to evaluate the performance of the model and significance of the parameters. The correlation coefficient between observed $T_{LEAF}$ and calculated $T_{BGT}$ obtained using an equation, developed to predict $T_{LEAF}$ based on $T_{BGT}$ was very high ($r^2=0.9500$, p < 0.0001). There was a positive relationship between $T_{BGT}$ and solar radiation ($r^2=0.8556$, p < 0.0001), but a negative relationship between $T_{BGT}$ and wind speed ($r^2=0.9707$, p < 0.0001). These results imply that heat exchange in leaves seems to be mainly controlled by solar radiation and wind speed. The correlation coefficient between actual and estimated $T_{BGT}$ was 0.9710 (p < 0.0001). Conclusions: The developed model can be used to accurately estimate the $T_{Leaf}$ of Cnidium officinale Makino and has the potential to become a practical alternative to assessing cold and heat stress.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Analysis of Eye Fatigue and Change of Eye Temperature according to Smartphone Usage Time (스마트폰 사용 시간에 따른 안구온도 변화와 눈의 피로도 분석)

  • Sun-Hee, Han;Bong-Hwan, Kim;Hyeong-Su, Kim;Jae-Wan, Jeong;Ji-Ae, Park;Chi-Hwan, Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.2
    • /
    • pp.1594-1599
    • /
    • 2022
  • Purpose. To investigate the relationship between changes in eye temperature and eye fatigue according to smartphone usage time. Methods. 15 adults in their 20s were asked to watch a smartphone, and the ocular surface temperature was measured 5 times each using a non-contact infrared thermometer every 10 minutes, and the change was observed. Result. The ocular surface temperature was 36.40℃ at the center of the cornea before watching the smartphone, but increased by 0.19℃ to 36.59℃ after watching the smartphone (SD 36.50±0.10). In addition, in the case of the sclera, it was found that the increase was 0.1℃ from 36.48℃ before viewing to 36.58℃ after viewing (SD 36.53±0.05). Conclusion. It was found that there is a close relationship between smartphone use and changes in eye temperature. In the future, it is thought that the ocular surface temperature can be used as basic data to objectively evaluate eye fatigue.

Study on the Possibility of Quantitative Measurement of Abdominal Examinations in Korean Medicine - A Focus on Diagnosis of Abdominal Coldness in Functional Dyspepsia Patients - (한의 복진 정량화 연구 - 기능성 소화불량 환자의 복냉 진단을 중심으로 -)

  • Lee, Jae-hong;Cho, Soo-ho;Ko, Seok-jae;Kim, Jin-sung;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.495-510
    • /
    • 2018
  • Objective: This study was designed to investigate the possibility of quantification of the diagnosis of abdominal coldness (AC) in patients with functional dyspepsia (FD). Methods: Forty-four patients with FD were enrolled in this study. Three Korean medicine doctors each randomly examined all abdomens. Diagnosis of AC was made by consensus of at least two of the doctors. Body temperature (oral by digital oral thermometer) and skin temperature (by digital infrared thermal imaging [DITI]) were measured, followed by administration of the Cold and Heat questionnaire (CHQ) and the Instrument of Pattern Identification for Functional Dyspepsia (IPIFD). Results: Of the 44 patients with FD, 22 were assigned to the AC group and 22 to the non-AC group. The concordance rate of diagnosis among the three doctors was 63.6% (28/44), with a ${\kappa}$ of 0.504, indicating means moderate agreement). Neither the oral nor the skin temperatures showed statistically significant differences between the AC and non-AC groups. However, the CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD were higher in AC group and showed statistically significant differences (p=0.010 and 0.009). Conclusions: This is the first study conducting quantitative measurements of abdominal coldness in patients with FD. Although oral and skin temperature showed no statistical significance between AC and non-AC groups, the concordance rate of diagnosis of AC among the three Korean Medicine doctors was moderate. The CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD also suggest that diagnosis of AC is relevant to cold and heat patterns, and these questionnaires could be utilized as supportive data for the diagnosis of AC. Further studies should be conducted for the purpose of quantifying and standardizing abdominal examinations in Korean Medicine.

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Surface and Chemical Properties of Surface-modified UHMWPE Powder and Mechanical Properties of Self Curing PMMA Bone Cement Containing UHMWPE Powder I. Effect of MMA/Xylene Contents on Surface Modification of UHMWPE (표면개질된 초고분자량 폴리에틸렌 분말의 표면과 화학적 특성 및 이를 함유하는 상온 경화용 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성 I. 메틸 메타크릴레이트/자일렌 함량에 따른 초고분자량 폴리에틸렌의 표면 개질 효과)

  • 양대혁;윤관희;김순희;이종문;강길선
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.77-85
    • /
    • 2004
  • It has been widely used ultra high molecular weight polyethylene (UHMWPE) for the biomaterials due to its excellent mechanical properties and biocompatibility. In the case of blend of UHMPE with another polymeric biomaterials, however, UHMWPE might have low blend compatibility due to surface inertness. In this study, in order to improve the mechanical properties of poly(methyl methacrylate) (PMMA) bone cement by means of the impregnation of UHMWPE powder, we developed the novel surface modification method by the mixture of methyl methacrylate (MMA) and xylene. We investigated the variation of composition of MMA/xylene. It was confirmed by the analysis of Fourier transform infrared-attenuated total reflectance, scanning electron microscope, universal transverse mercator, and digital thermometer. The maximum mechanical strength of surface modified UHMWPE powder impregnated PMMA bone cement compound was observed the ratio of 1 : 1 (v/v%) MMA/xylene. Also its curing temperature decreased from 103 $^{\circ}C$ to 58 ∼ 73 $^{\circ}C$ The mechanism of surface modification of UHMWPE powder by the mixture of MMA/xylene has been proposed.

Comparison of Non-desructive Method to Detect Nitrogen Deficient Cucumber (질소결핍 오이의 비파괴 진단법 비교)

  • 성제훈;서상룡;류육성;정갑채
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.539-546
    • /
    • 1999
  • Some stress for a plant could be detected to a certain degree by plant physiological measuring technique of the state of the art. The capability of early detection of my measuring system depends on kind of plant and kind and level of stress. The objectives of this study were to evaluate the capability of several fast and intact type plant stress detection systems to detect nitrogen deficiency of cucumber in the field. A series of experiment was carried out with four kinds of intact type measuring devices - a chlorophyll content meter, a chlorophyll fluorescence measurement system, an infrared thermometer and an optical spectrometer. The experiments resulted that the chlorophyll content meter could detect the stress of N deficiency at a confidence level higher than 95% on 3rd day for the earliest case and the detection of high precision was possible from 7th day after the stress was applied. The chlorophyll fluorescence measurement system detected the stress at a confidence level higher than 95% on 3rd day for the earliest case but the detection was not as much precise as the chlorophyll content meter. Leaf temperature measurement noted very poor results to detect the stress. Using the spectrometer, sensitive wavelength regions to detect the stress were searched and found out as 562∼564 nm, 700∼724 nm and 1,886∼1,894 nm. With the spectrometer using any of wavelength within the sensitive wavelength region, detection of the stress at a confidence level higher than 95% was possible from 3rd or 4th day after the stress was applied.

  • PDF

A Study on Wear Characteristics of Cutting Tools in a Titanium Roughing Cut Machining (티타늄 황삭가공에 있어서 절삭공구의 마모 특성에 관한 연구)

  • Bae, Myung-whan;Jung, Hwa;Park, Hyeong-yeol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.67-73
    • /
    • 2016
  • The application of titanium has been gradually rising because the utilizing ranges for low weight and high strength are rapidly increased by the need for improving the fuel economy in production industries such as the aviation and automotive in recent. The purpose in this study is to investigate the appropriate cutting conditions on the life of flat and round end mills by measuring the maximum cutting temperature relative to the machining time, and calculating the wear rates of cutting tool with the spindle speed and feed rate of vertical machining center as a parameter in the titanium roughing cut machining which is widely used in critical parts of aircraft, cars, etc. When the wetted roughing cut machining of titanium with a soluble cutting oil is conducted by the flat and round end mills, the maximum cutting temperatures for a variety of spindle speed and feed rate are measured at ten-minute intervals during 60 minutes by an infrared thermometer, and the wear rates of cutting tool are calculated by the weight ratios based on tool wear before and after the experiment. It is found that the maximum cutting temperature and the wear rates of cutting tool are raised as the cutting amount per tool edge is increased with the rise of feed rate, in this experimental range, and as the frictional area due to the rise of contacting friction numbers between tool and specimen is increased with the rises of cutting time and spindle speed. In addition, the increasing rate of maximum cutting temperature in the flat and round end mills are the highest for the cutting time from 50 to 60 minutes, and the wear rate of cutting tool in the flat end mill is 1.14 to 1.55 times higher than that in the round end mill for all experimental conditions.