• Title/Summary/Keyword: Indoor Pollutant

Search Result 140, Processing Time 0.024 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Runoff Analysis for Weak Rainfall Event in Urban Area Using High-ResolutionSatellite Imagery (고해상도 위성영상을 이용한 도시유역의 소강우 유출해석)

  • Kim, Jin-Young;An, Kyoung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.439-446
    • /
    • 2011
  • In this research, enhanced land-cover classification methods using high-resolution satellite image (HRSI) and GIS in terms of practicality and accuracy was proposed. It aims for understanding non-point pollutant origin/loading, assessment the efficiency of rainfall storage/infiltration facilities and sounds water-environment management. The result of applying enhanced land-cover classification methods to the urban region verifies that roof and road area are including various vegetations such as roof garden, flower bed in the median strip and street tree. This accounts for 3% of total study area, and more importantly it was counted as impervious area by GIS alone or conventional indoor work. The feasibility of the method was assessed by applying to rainfall-runoff analysis for three weak rainfall in the range of 7.1-10.5 mm events in 2000, Chiba, Japan. A good agreement between simulated and observed runoff hydrograph was obtained. In comparison, the hydrograph simulated with land-use parameters by the detailed land-use information of 10m grid had an error between 31%~71%, while enhanced method showed 4% to 29%, and showed the improvement particularly for reproducing observed peak and recession flow rate of hydrograph in weak rainfall condition.

Research on the Actual State of Environmental Disease and Health Education at Middle and High School Students (일 지역 중.고등학생들의 환경성 질환 및 보건교육 실태 조사)

  • Jung, Jong-Hyeon;Moon, Ki-Nai;Seo, Bo-Soon;Kim, Chang-Tae;Lee, Jae-Hong
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.12 no.3
    • /
    • pp.65-87
    • /
    • 2011
  • Objectives: The purpose of this study was to perform basic study on environmental and respiratory diseases in Ulsan and vicinities. Also, this study evaluated the actual state of environmental disease and health education at middle and high schools in Ulsan and surroundings. Methods: For this study, we conducted a survey on the health of the general public, environmental effects, and investigated the characteristics of environmental disease, health and hygiene education, etc. The populations of this study were middle and high school students in Ulsan, Korea. This study investigated the knowledge of environmental disease and health education at schools in Ulsan and vicinities from November 2009 to December 2009. All statistical calculations were performed with Statistical Package for Social Sciences (SPSS) for Windows, and gained the following results by implementing Frequency Analysis, Cross-tabulation Analysis and ANOVA. Results: As more and more environmental diseases are increased, the interest of the people has been increasing on this. The incidence rates of asthma and atopy were represented the top 25% of the country in Korea. The source of heavy metal, PAHs and VOCs in Ulsan includes the Petrochemical Complex at Nam-gu and Ulju-gun, the Nonferrous Metal Industrial Complex at Onsan-eup, Ulju-gun, and the Heavy Industrial Complex at Dong-gu and Buk-gu. Especially, there are a number of fossil fuel combustion facilities such as waste incineration plants and boilers at Nam-gu and the Onsan Industrial Complex. It may help greatly to investigate the characteristics of environmental pollutants such as environmental air pollutant and indoor contaminant to better manage the local student's health. Conclusions: It has been revealed that the hazardous chemicals and environmental contaminants are main substances of cause for asthma, atopy, dermatitis, and allergy disease. Therefore, through with collecting basic data such as environmental disease of inhabitants, health education, conscious and knowledgeable level in parents of students and students, We have to exert to improve knowledge and prevention with health life in school through development of health education program systematically for preventing of environmental disease.

  • PDF

Risk Assessment of Nitrogen Dioxide for Hematological and Biochemical Parameter in Mice (Mice를 이용한 혈액 및 생화학적 특성에 대한 Nitrogen Dioxide의 위해성 평가)

  • Jeong, Seong-Wook;Han, Yong-Soo;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.665-670
    • /
    • 2007
  • In this study, we evaluated the property change and relationship between hematological and biochemical parameters in exposure group and control group by multiple inhalation exposure, of $NO_2$. In case of leukocyte, change of hematological property increased significantly in statistics (p<0.05) in mice experiment. in case of hematocrit of exposure group, it was of decreased significantly in statistics. the tendency of hemoglobin and hematocrit was similar to all for three case. in case of methmoglobin that of the exposure group in mice experiment was meaning increased(p<0.05). For the $NO_2$ influence in biochemical property, total protein and triglyceride was decreased but not significant in statistics, albumin was decreased in the exposure group in the animal experiments, blood urea nitrogen and creatinine increased significantly in statistics in the animal experiments. uric acid and lactate dehydrogenase in serum increased significantly in the exposure group. We have to evaluate risk assessment for the $NO_2$ of indoor air pollutant in low concentration and long time.

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

Source Proximity and Meteorological Effects on Residential Ambient Concentrations of PM2.5, Organic Carbon, Elemental Carbon, and p-PAHs in Houston and Los Angeles, USA

  • Kwon, Jaymin;Weisel, Clifford P.;Morandi, Maria T.;Stock, Thomas H.;Turpin, Barbara
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1349-1368
    • /
    • 2016
  • Concentrations of fine particulate matter ($PM_{2.5}$) and several of its particle constituents measured outside homes in Houston, Texas, and Los Angeles, California, were characterized using multiple regression analysis with proximity to point and mobile sources and meteorological factors as the independent variables. $PM_{2.5}$ mass and the concentrations of organic carbon (OC), elemental carbon (EC), benzo-[a]-pyrene (BaP), perylene (Per), benzo-[g,h,i]-perylene (BghiP), and coronene (Cor) were examined. Negative associations of wind speed with concentrations demonstrated the effect of dilution by high wind speed. Atmospheric stability increase was associated with concentration increase. Petrochemical source proximity was included in the EC model in Houston. Area source proximity was not selected for any of the $PM_{2.5}$ constituents' regression models. When the median values of the meteorological factors were used and the proximity to sources varied, the air concentrations calculated using the models for the eleven $PM_{2.5}$ constituents outside the homes closest to influential highways were 1.5-15.8 fold higher than those outside homes furthest from the highway emission sources. When the median distance to the sources was used in the models, the concentrations of the $PM_{2.5}$ constituents varied 2 to 82 fold, as the meteorological conditions varied over the observed range. We found different relationships between the two urban areas, illustrating the unique nature of urban sources and suggesting that localized sources need to be evaluated carefully to understand their potential contributions to $PM_{2.5}$ mass and its particle constituents concentrations near residences, which influence baseline indoor air concentrations and personal exposures. The results of this study could assist in the appropriate design of monitoring networks for community-level sampling and help improve the accuracy of exposure models linking emission sources with estimated pollutant concentrations at the residential level.

Formaldehyde Adsorption Properties of Activated Carbon Fiber-Papers by Nitrogen Plasma Treatment (질소 플라즈마 처리에 따른 활성탄소섬유 페이퍼의 포름알데하이드 흡착 특성)

  • Min, Chung Gi;Lim, Chaehun;Myeong, Seongjae;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.624-629
    • /
    • 2022
  • Formaldehyde is an indoor pollutant that is harmful to humans, such as causing respiratory and skin diseases. Nitrogen plasma treatment was performed to introduce nitrogen groups on the surface of the activated carbon fibers (ACFs), and the adsorption characteristics of formaldehyde for the surface-modified ACFs were considered. As the nitrogen gas flow rate increased, the content of nitrogen functional groups introduced to the surface of the ACFs increased by about 7%, and the ratio of nitrogen functional groups to each type present was similar. Ultramicropores increased on the ACFs surface due to the etching effect of plasma treatment. The adsorption efficiency of formaldehyde on the modified ACFs surface was also enhanced. However, under the nitrogen flow rate of 120 sccm or more, the surface of the ACFs was excessively etched, and the specific surface area and the formaldehyde adsorption capacity decreased. Therefore, the content of the nitrogen groups is the main factor in the adsorption of formaldehyde on the nitrogen plasma-treated ACFs, but it can be found that the adsorption efficiency of formaldehyde is improved when the ACFs have a suitable pore structure.

Anti-inflammatory Effects of Inhalation of Injured Starfish Extracts on Formaldehyde Exposure (손상된 불가사리 추출물 흡입이 포름알데히드 노출에 의한 항염증 작용에 미치는 효과)

  • Hwang, Kyung Hee;Chang, Su Chan;Park, Jong Seok;Wahid, Fazli;Kim, You Young
    • Journal of Life Science
    • /
    • v.23 no.4
    • /
    • pp.501-509
    • /
    • 2013
  • Formaldehyde (FA) is widely used in industries, and it is an indoor and outdoor pollutant. Exposure to FA may cause inflammation and respiratory oxidative stress. Studies have demonstrated that FA can cause cancer in animal models. During the regeneration process of injured starfish (Asterina pectinifera), several changes have been observed in the expression of cytokines. In particular, higher TGF-${\beta}1$ expression has been detected in arm cut starfish extract after eight days. The current study was designed to elucidate the in-vitro and the in-vivo pharmacological effects of starfish extract on FA exposure. We investigated the protective effects of intact starfish extract and arm cut starfish extract on an IMR-90 cell line and on mouse lung injury in response to FA exposure. In the presence of FA, inhalation of the arm cut starfish extract was associated with more promising cell proliferation, TNF-${\alpha}$, NF-${\kappa}B$ decrement, and $I{\kappa}-B{\alpha}$ increment. In the experimental group, the pulmonary structure of the arm cut starfish extract-treated group in the presence of FA exposure was similar to the control group, whereas the FA exposure group showed damage to the pulmonary structure. Moreover, the arm cut starfish extracts was more effective than the intact starfish extracts in terms of the expression of TNF-${\alpha}$, NF-${\kappa}B$, $I{\kappa}-B{\alpha}$, and surfactant protein A. The results obtained in this study demonstrate that arm cut starfish extracts are more effective in protecting pulmonary structure and function against FA exposure than intact starfish extracts.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.