Browse > Article
http://dx.doi.org/10.6110/KJACR.2014.26.12.605

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013  

Lee, Dae-Young (Korea Institute of Science and Technology)
Kim, Sa Ryang (School of Mechanical and Automotive Engineering, Gangneung-Wonju National University)
Kim, Hyun-Jung (Department of Mechanical Engineering, Ajou University)
Kim, Dong-Seon (Department of Mechanical Engineering, Korea National University of Transportation)
Park, Jun-Seok (Department of Architecture Engineering, Hanyang University)
Ihm, Pyeong Chan (Department of Architecture Engineering, Dong-A University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.26, no.12, 2014 , pp. 605-619 More about this Journal
Abstract
This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.
Keywords
Fluid machinery; Duct; Pipe; Fuel cell; Organic Rankine cycle; Heat transfer; Cooling and heating; Air conditioning; Refrigeration; Fluid flow; Building facility; Built environment; Piping; New and renewable energy; Heat exchanger; Heat pipe; Phase change; Alternative refrigerants; Heating; Ventilation; Indoor air quality; Thermal comfort; Load analysis;
Citations & Related Records
Times Cited By KSCI : 98  (Citation Analysis)
연도 인용수 순위
1 Lee, Y. T., 2013, Porometric study on the gas diffusion layer in PEMFCs using method of standard porosimetry, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 64-69.   과학기술학회마을   DOI
2 Heo, H.-J., Jeong, J.-U., Kim, J.-D., Choi, J.-B., Choi, S.-C., and Hwang I.-J., 2013, Qualitative RBI analysis in considered with uncertain variables by probabilistic distribution, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 70-78.   과학기술학회마을   DOI
3 Jung, Y.-H., Chang, H.-J., and Seo, J.-H., 2013, Server room temperature condition in data center with cold aisle containment system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 79-84.   과학기술학회마을   DOI
4 Jeong, S.-K. and Hong, K.-H., 2013, Optimal PI controller design for refrigeration system considering disturbance, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 85-93   과학기술학회마을   DOI
5 Chung, K.-S., Kim, C.-H., and Cho, H.-S., 2013, Effect of rear-vortex of a convergent-divergent duct on the flow acceleration installed in a vertical structure, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 94-100.   과학기술학회마을   DOI   ScienceOn
6 Choi, K.-I. and Oh, J.-T., 2013, Boiling heat transfer of ammonia inside horizontal smooth small tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 101-108.   과학기술학회마을   DOI
7 Kim, D.-S. and Lee, D.-Y., 2013, Development of a general analytical model for desiccant wheels, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 109-118.   과학기술학회마을   DOI
8 Yoo, S.-Y. and Kim, T.-H., 2013, A study on the effects of water absorption on the thermal conductivity of insulation materials, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 119-125.   과학기술학회마을   DOI
9 Kim, S. H., Jeong, S.-G., and Kim, S. M., 2013, Preparation and thermal properties of octadecane/xGnP shapestabilized phase change materials to improve the heat storage performance of buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 126-130.   DOI   ScienceOn
10 Bae, H. H., Lee, D. H., Lee, S. H., Kim, B. S., and Kim, Y. C., 2013, A study on the performance improvement of a simultaneous heating and cooling water source heat pump system by controlling of the refrigerant flow rate in an outdoor unit, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 131-136.   과학기술학회마을   DOI
11 Ahn, J. H., Joo, Y. J., Yoon, W. J., Kang, H., and Kim, Y. C., 2013, An experimental study on the performance characteristics of hot-gas and liquid bypass heat pump systems for capacity modulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 137-142.   과학기술학회마을   DOI
12 Lee, Y. H., Kang, D. G., Seo, H., and Jung, D. S., 2013, Pool boiling heat transfer coefficients of R1234yf on various enhanced surfaces, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 143-149.   과학기술학회마을   DOI
13 Lee, J.-M., Cho, S., Lim, S.-H., and Song, K.-D., 2013, Analyses of energy savings and night heating performance of a movable thermal insulation shuttered window, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 150-155.   과학기술학회마을   DOI
14 Park, H. V., Yin, R., and Kim, Y. D., 2013, Optimum design of middle-Sized $CO_2$ water heater, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 173-179.   과학기술학회마을   DOI
15 Kong, H. J., Kang, S. J., Yun, K. S., and Lim, H. J., 2013, An experimental study on the cooling and heating performance of a residential ground source heat pump system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 156-163.   과학기술학회마을   DOI   ScienceOn
16 Kim, Y.-J., Jung, C. W., Lee, Y. J., Kim, S. S., and Kang, Y. T., 2013, Performance improvement of Cured-In-Place-Pipe(CIPP) process by boiler waste heat recovery, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 164-167.   과학기술학회마을   DOI
17 Park, J.-T., Lee, Y.-S., Kim, J. Y., Chae, K.-J., and Yang, H.-J., 2013, A study on the operating control of a heat pump system with screw compressors, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 168-172.   과학기술학회마을   DOI
18 Woo, H. S., Ahn, J. H., Oh, M. S., Kang, H., and Kim Y. C., 2013, Study on the heating performance characteristics of a heat pump system utilizing air and waste heat source for electric vehicles, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 180-186.   과학기술학회마을   DOI   ScienceOn
19 Park, Y. H., Park, J. H., Park, J. C., and Rhee, E. K., 2013, A study on the application of small wind turbine system in super high-rise building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 187-193.   과학기술학회마을   DOI   ScienceOn
20 Kwon, S. W. and Hong, J. K., 2013, An experimental study on the deodorization performance of exhaust filter unit in a laboratory animal breeding facility, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 194-200.   과학기술학회마을   DOI
21 Cho, H. H., Lee, H. S., and Park, C. S., 2013, Study on the performance improvement for an automobile air conditioning system using alternative refrigerant R1234yf, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 201-207.   과학기술학회마을   DOI
22 Eom, H. S., Yoon, C. S., and Kim, Y. M., 2013, Experimental study on the operating characteristics of the organic Rankine cycle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 208-215.   과학기술학회마을   DOI   ScienceOn
23 Won, J.-S., Cho, G.-H., and Ju, K.-B., 2013, Development method of BIM data modeling guide for facility management : Focusing on building mechanical system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 4, pp. 216-224.   과학기술학회마을   DOI   ScienceOn
24 Song, J. H., Jung, H. W., Park, J. W., Kang, H., and Kim, Y. C., 2013, Numerical study of the performance characteristics of a cascade heat pump water heater at low ambient temperatures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 225-232.   과학기술학회마을   DOI
25 Yun, R., 2013, Thermophysical properties of $CO_2$ and $CO_2$-Hydrate mixture and in-tube heat transfer characteristics, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 233-239.   과학기술학회마을   DOI
26 Lee, B. U. and Lee, J. K., 2013, Numerical investigation on wall flow control for preventing contaminants deposition inside a duct, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 261-268.   과학기술학회마을   DOI
27 Sung, T.-K., Lee, C.-S., Kim, J.-M., Joung, C.-B., and Kim, B.-C., 2013, Development of solar daylighting system using parabolic mirrors, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 240-245.   과학기술학회마을   DOI
28 Kye, S.-H. and Kim, D.-S., 2013, Flow characteristics of a gas-liquid slug flow in small vertical tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 246-254.   과학기술학회마을   DOI   ScienceOn
29 Kim, J.-Y., Shin, H.-J., Kim, J.-S., and Joo, S.-H., 2013, Study on induction capability of chilled beam HVAC system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 255-260.   과학기술학회마을   DOI   ScienceOn
30 Lee, G. H., Bang, Y. S., Woo, S. W., Kim, D. H., and Kang, M. K., 2013, Numerical analysis for the effect of flow skirt geometry on the flow distribution in the scaledown APR+, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 269-278.   과학기술학회마을   DOI
31 Choi, B.-N., Yi, F., Sin, H.-M., and Kim, N.-H., 2013, Air-side performance of fin-and-tube heat exchangers having sine wave fins and oval tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 279-288.   과학기술학회마을   DOI
32 Kwak, Y.-H., Cheon, S.-H., Jang, C.-Y., and Huh, J.-H., 2013, Real-time energy demand prediction method using weather forecasting data and solar model, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 310-316.   과학기술학회마을   DOI
33 Yoo, K.-P., Han, M. S., Kim, J.-D., and Choi, W.-T., 2013, A computational study on the cooling performance of a near infrared radiative heating system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 289-296.   과학기술학회마을   DOI
34 Nam, Y. J. and Chae, H.-B., 2013, Prediction of the heat exchange rate for a horizontal ground heat pump system using a ground heat transfer simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 297-302.   과학기술학회마을   DOI
35 Hwang, I. S. and Lee, Y. L., 2013, A study on performance test and fabrication of vacuum glazing with numerical analysis, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 303-309.   과학기술학회마을   DOI
36 Lee, S.-K. and Lee, J.-K., 2013, Effect of the orifice area ratio on the exit flow of a multi-perforated tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 317-323.   과학기술학회마을   DOI
37 Lee, J. K., 2013, Effect of inlet geometries on the twophase flow distribution at header-channel junction, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 324-330.   DOI
38 Hahm, H. C. and Park, C. Y., 2013, Experimental study on the performance of an electric component liquid cooling system with variation of the waterblock internal shape, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 331-337.   과학기술학회마을   DOI
39 Cho, J. K., Shin, S. H., Kim, J. H., Hwang, D. K., and Hong, H. K., 2013, Development of an HVAC&R systems energy evaluation methodology and simulation program for office buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 363-370.   과학기술학회마을   DOI
40 Kwak, H.-J., Jang, H.-I., Lee, H.-S., Eom, J.-Y., and Suh, S.-J., 2013, Correlation analysis between fenestration energy consumption efficiency rating system and building energy consumption, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 338-345.   과학기술학회마을   DOI
41 Park, S. H., Seo, J. H., Jung, Y.-H., Chang, H.-J., and Hwang, S.-H., 2013, Energy consumption analysis based on filter differential pressure when adopting an air-side economizer system for a data center, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 371-376.   과학기술학회마을   DOI   ScienceOn
42 Kim, K.-H., Cho, Y.-S., and Kim, H.-J., 2013, Investigation of local flow parameters caused by flow acceleration corrosion downstream of an orifice in a piping system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 377-385.   과학기술학회마을   DOI
43 Oh, S.-H., Yun, R., and Cho, Y., 2013, Cooling and heating operation characteristics of raw-water source heat pump and air source heat pump in water treatment facility, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 386-391.   과학기술학회마을   DOI
44 Lee, W.-J., Kang, E.-C., Lee, E.-J., Oh, B.-C., and Shin, U.-C., 2013, EA study on the operation performance of central plant equipment according to part load characteristics, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 392-397.   과학기술학회마을   DOI
45 Sohn, B. H. and Hwang, E.-K., 2013, Subway station's seating capacity of temporary evacuees from disastrous situation through analyzing the number of toilets, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 418-426.   DOI
46 Kim, Y. C. and Choi, J. M., 2013, Numerical simulation of a system heat pump adopting an integral optimum regulating controller, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 398-405.   과학기술학회마을   DOI
47 Shin, Y. G., Kim, J. H., and Yoo, B. J., 2013, Dynamic modeling and simulation of a hybrid heat pump, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 406-412.   과학기술학회마을   DOI
48 Chang, H.-S., Song, Y.-K., and Han, Y.-S., 2013, Performance analysis of an ORC system for two different working fluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 413-417.   과학기술학회마을   DOI
49 Nam, Y. J., 2013, Numerical analysis of the effect of ground source heat pump systems on the underground temperature, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 427-431.   과학기술학회마을   DOI
50 Jeong, S.-G., Yu, S. G., Jang, S. A., Park, J.-S., Kim, T. H., Lee, J.-H., and Kim, S. M., 2013, Preparation of shape stabilized PCM using porous materials for application to buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 432-437.   과학기술학회마을   DOI
51 Nam, H.-K., Bai, S. E., Bai, C.-H., Ko, J.-S., Jin, B.-J., and Oh, J.-C., 2013, A study on the reliability of cooling water systems using R436B, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 438-442.   과학기술학회마을   DOI
52 Shin, Y. G., Kim, E. J., and Kim, T. H., 2013, Development of a renewable energy facility design and its simulation case study, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 464-470.   과학기술학회마을   DOI
53 Song, S. W., 2013, An experimental study on variablespeed control of an ground-water circulation pump for a ground source multi-heat pump system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 443-449.   DOI
54 Park, Y. H., Kim, Y. J., Jung, Y. M., and Park, W.-G., 2013, Study on the internal flow of an electric oven with variation of steam outlet position, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 450-456.   과학기술학회마을   DOI
55 Kwon, O. K. and Chung, J. D., 2013, Numerical analysis of the heat and mass transfer in a fin tube type adsorber, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 457-463.   과학기술학회마을   DOI
56 Ha, J. S., 2013, A study on the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 8, pp. 471-476.   과학기술학회마을   DOI
57 Kim, H. K., Lee, D. G., Peck, J. H., and Kang, C. H., 2013, Numerical study of heat transfer with selective phase change in two different phase change materials, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 477-483.   과학기술학회마을   DOI
58 Kang, D.-G., Lee, Y. H., and Jung, D. S., 2013, Pool boiling heat transfer coefficient of HFC32/HFC152a on a plain surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 484-492.   과학기술학회마을   DOI
59 Kim, S. H., Myoung, C. W., and Cho, H. H., 2013, Performance simulation of a R744 refrigeration system in a refrigerator truck under a frost condition, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 499-505.   과학기술학회마을   DOI
60 Kim, G. T., Yoo, J.-H., Hwang, H.-J., and Kim, K.-S., 2013, A study on the calculation method of infiltration for detached houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 493-498.   과학기술학회마을   DOI
61 Kim, H., 2013, Ventilation measurement with PFT in three-storied detached house, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 506-515.   과학기술학회마을   DOI
62 Kwon, Y. C., Kim, K. Y., Lee, S.-H., and Kwon, J. T., 2013, Experimental study on the heat transfer capacity and dehumidification performance of a parallel flow evaporator for a heat pump dryer, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 9, pp. 516-521.   과학기술학회마을   DOI
63 Lee, Y. H., Kang, D.-G., and Jung, D. S., 2013, Heat transfer characteristics of spray cooling up to critical heat flux on a low-fin enhanced surface, Vol. 25, No. 9, pp. 522-528.   과학기술학회마을   DOI
64 Jeon, B.-H., Kim, J.-W., Lee, S.-K., Lee, Y.-J., and Ahn, Y.-C., 2013, A study on the dew condensation according to the operational conditions of a heat-recovery ventilator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 529-533.   과학기술학회마을   DOI
65 Kang, B. H., Yun, C. H., and Ahn, J., 2013, Impact of residential CHP systems on greenhouse gas emissions in Korea, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 555-561.   과학기술학회마을   DOI
66 Hwang, J. H., Hong, J. K., and Ju, Y. D., 2013, A study on the risk assessment and reduction of initial construction cost in a biosafety laboratory according to improvement of supply and exhaust method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 534-539.   과학기술학회마을   DOI
67 Han, S.-Y., Kim, S.-H., Jang, H.-I., Lee, S.-H., and Suh, S.-J., 2013, An experimental study on the applicability of a multiplex heat pump system in the kindergarten, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 540-547.   과학기술학회마을   DOI
68 Oh, H.-K., Son, C.-H., Yi, W.-B., and Jeon, M.-J., 2013, Performance analysis of R404A refrigeration system with internal heat exchanger using R744 as a secondary refrigerant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 548-554.   과학기술학회마을   DOI
69 Kim, J.-Y. and Kim, J.-S., 2013, Study on numerical model of leakage flow at gap between compartments in a building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 562-567.   과학기술학회마을   DOI
70 Choi, S.-H. and Wang, J.-N., 2013, A method of residual stress improvement by plastic deformation in the pipe welding zone, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 10, pp. 568-572.   과학기술학회마을   DOI
71 Park, Y., Ahn, Y.-C., Kim, H.-D., Kim, J.-S., Goark, Y.-S., and Kim, Y.-K., 2013, An applicability estimation of plastic vertical pipes using electric fusion fittings through measurement, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 595-599.   과학기술학회마을   DOI
72 Won, J.-S. and Nam, J.-W., 2013, The condensation risk assessment of vacuum multi-layer glass and triple glass using the temperature difference ratio, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 573-577.   과학기술학회마을   DOI   ScienceOn
73 Sung, S.-K. and Ahn, K.-C., 2013, Performance variation of the refrigerated display case with air curtain in accordance with back pressure condition, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 578-584.   과학기술학회마을   DOI
74 Byun, J.-K., Yun, S.-H., Nam, K.-H., Choi, Y.-D., and Shin, J.-K., 2013, A study on the development of a multi-heat supply control algorithm in a district heating apartment building in accordance with the variation of outdoor air temperature, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 585-594.   과학기술학회마을   DOI
75 Chae, H.-B., Nam, Y. J., and Park, Y.-B., 2013, An economic analysis and performance prediction for a ground heat pump system with barrette pile, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 600-605.   과학기술학회마을   DOI
76 Lee, Y. G. and Shin, C. W., 2013, The air leakage characteristics and airtightness performance of a newly built apartment, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 606-611.   과학기술학회마을   DOI
77 Song, J.-K., Cho, G.-H., and Ju, K.-B., 2013, A study on the rule development for BIM-based automatic checking in a duct system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 631-639.   과학기술학회마을   DOI
78 Kwon, Y. P., 2013, A study on the development of a circular CAV damper, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 612-616.   과학기술학회마을   DOI
79 Choi, B.-H. and Kang, J.-S., 2013, The thermal performance of building insulation materials according to long-term aging, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 617-623.   과학기술학회마을   DOI
80 XU LEI, Kim W. U., Lee, S.-R., and Kim, Y. C., 2013, The discharge performance optimization of a forced convection type PCM refrigeration module used in a refrigeration truck, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 624-630.   과학기술학회마을   DOI
81 Lim, C. H., Kim, D. W., Kim, Y. C., and Seo, K. J., 2013, Study on the cooling performance of single and cascade refrigeration systems using thermoelectric modules, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 641-646.   과학기술학회마을   DOI
82 Lee, H. H., Lee, S. J., Song, J. H., Kim, S. M., Lim, J. H., and Song, S.-Y., 2013, Study on the characteristics of thermal output and thermal storage in a thermally activated building system with phase change material, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11, pp. 647-653.   과학기술학회마을   DOI   ScienceOn
83 Kim, J. H., Yoo, J. S., and Park, J. I., 2013, Fabrication and performance investigation of surface temperature sensor using fluorescent nanoporous thin film II, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 674-678.   과학기술학회마을   DOI
84 Ryu, K. J. and Lee, S.-S., 2013, Louvered fin heat exchanger : optimal design and numerical investigation of heat and flow characteristics, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 654-659.   과학기술학회마을   DOI
85 Ahn, S. H., Hong, S. W., Kwon, O. K., and Chung, J. D., 2013, Validity of inter-particle models for the mass-transfer kinetics of a fin-tube-type adsorption bed, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 660-667.   과학기술학회마을   DOI   ScienceOn
86 Kim, J. H., Yoo, J. S., and Park, J. I., 2013, Fabrication and performance investigation of surface temperature sensor using fluorescent nanoporous thin film I, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 668-673.   과학기술학회마을   DOI
87 Kim, S. H., Lee, Y. G., and Seo, Y. M., 2013, Development of correlation analysis on the test methods of furniture-like products, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 679-684.   과학기술학회마을   DOI
88 Ahn, B.-C. and Song, J.-Y., 2013, A study on the operational strategies for outdoor air temperature change characteristics in a radiant floor heating system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 685-692.   과학기술학회마을   DOI
89 Park, D.-I., Chung, K.-S., Kim, Y.-I., and Kim, S.-M., 2013, A study on the development of oxygen cluster ion generator for sterilization of bio clean room(BCR), Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 7-13.   과학기술학회마을   DOI
90 Oh, B.-K., Chung, M.-H., Won, J.-S., and Lee, H., 2013, A study of exhaust air flow for cooling load reduction from interior lighting, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 1-6.   과학기술학회마을   DOI
91 Yoon, S.-H., Jang, H.-I., Kim, K.-A., Yu, K.-H., and Suh, S.-J., 2013, An energy performance evaluation of UFAD system under the various conditions of thermal load, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 14-19.   과학기술학회마을   DOI
92 Kim, M.-K., Park, H.-S., and Song, K.-D., 2013, Evaluation and analysis of building energy rating system according to insulation performance of building envelope in regional and building form of apartment house, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 49-54.   DOI   ScienceOn
93 Lee, K.-H., 2013, Comparative study on size optimization of a solar water heating system in the early design phase using a RETScreen model with TRNSYS model optimization, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 12, pp. 693-699.   과학기술학회마을   DOI
94 Park, H. V. and Yun, R., 2013, Studies on performance of $CO_2$ water heater by numerical modeling, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 20-27.   과학기술학회마을   DOI   ScienceOn
95 Sohn, B., Jung, K.-S., and Choi, H., 2013, Performance prediction of geothermal heat pump(GHP) system using cast-in-place energy piles, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 28-36.   과학기술학회마을   DOI
96 Kim, M.-S., Kim, Y., and Chung, K.-S., 2013, A study on the status and improvement of double pipe system in apartment buildings, Vol. 25, No. 1, pp. 37-42.   과학기술학회마을   DOI
97 Jeon, S.-T. and Cho, J.-P., 2013, Effect of pitch angle and blade length on an axial flow fan performance, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 1, pp. 43-48.   과학기술학회마을   DOI
98 Kim, K.-C., Song, G.-S., Kim, H.-T., Yoo, K.-H., Shin, D.-K., and Park, D.-J., 2013, An assessment of energy consumption in steam-humidification and water-sprayhumidifi cation-type outdoor air conditioning systems for semiconductor manufacturing clean rooms, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 2, pp. 55-63.   과학기술학회마을   DOI