• Title/Summary/Keyword: In-kind Transfer

Search Result 249, Processing Time 0.023 seconds

A Study on the Improvement of the Condensation Heat Transfer Performance of the Helical Grooved and Plain Thermosyphons (나선 그루브와 평관형 열사이폰의 응축열전달 성능 향상에 관한 연구)

  • Han, K.I.;Park, J.U.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.47-53
    • /
    • 2006
  • This study concerns the performance of condensation heat transfer in plain and grooved thermosyphons. Distilled water, methanol, ethanol have been used as the working fluids. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A study was carried out with the characteristics of heat transfer of the thermosyphon 50, 60, 70, 80, 90 helical grooves in which boiling and condensation occur. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon, the kinds of working fluid, the inclination angle, grooves and operating temperature have been used as the experimental parameters. The experimental results show that the number of grooves, the amount of the working fluid, the kind of working fluid, angle of inclination angle are very important factors for the operation of thermosyphon. The maximum heat transfer was obtained when the liquid fill was about 20 to 25 % of the thermosyphon volume. The relatively high rates of heat transfer have been achieved in the thermosyphon with grooves. The helical grooved thermosyphon having 70 to 80 grooves in water, 60 to 70 grooves in methanol and 70 to 80 grooves in ethanol shows the best heat transfer coefficient in both condensation.

  • PDF

The Calculation Method with index for the Transfer Power limit to Capital Area (지수를 적용한 수도권 융통전력한계량 계산)

  • Lee, Woon-Hee;Kang, Myung-Jang;Song, Suk-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.50-52
    • /
    • 2008
  • We have limited the transfer power to capital area below a certain level which is called "The Capital Area Transfer Power Limit", and calculated on every Thursday for the application next week. This level is very important in our network operation, because if this level is not set properly, our power network can be fallen under great danger in case of a fault among the transfer power line. But the calculation procedure for the limit level is so complicated and iterative that it mace us spend much time and do much work. So, when a sudden trip of the related facility to the limit level we can't recalculate the limit level fast enough. And this can drop our network reliability below our standards, therefore our network can be dangerous. To avoid this kind of problems, we have figured out a method to calculate simply the limit level. That method uses the index related to the level. We think this method can make short of the calculation procedures for the level. This paper deals with the simplified method for the calculation of the level limit.

  • PDF

Embedded Object-Oriented Micromagnetic Frame (OOMMF) for More Flexible Micromagnetic Simulations

  • Kim, Hyungsuk;You, Chun-Yeol
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.491-495
    • /
    • 2016
  • We developed an embedded Object-Oriented Micromagnetic Frame (OOMMF) script schemes for more flexible simulations for complex and dynamic mircomagnetic behaviors. The OOMMF can be called from any kind of softwares by system calls, and we can interact with OOMMF by updating the input files for next step from the output files of the previous step of OOMMF. In our scheme, we set initial inputs for OOMMF simulation first, and run OOMMF for ${\Delta}t$ by system calls from any kind of control programs. After executing the OOMMF during ${\Delta}t$, we can obtain magnetization configuration file, and we adjust input parameters, and call OOMMF again for another ${\Delta}t$ running. We showed one example by using scripting embedded OOMMF scheme, tunneling magneto-resistance dependent switching time. We showed the simulation of tunneling magneto-resistance dependent switching process with non-uniform current density using the proposed framework as an example.

Stability analysis of gas-liquid interface using viscous potential flow (점성포텐셜유동을 이용한 이상유동장의 표면안정성 해석)

  • Kim, Hyung-Jun;Kwon, Se-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3033-3038
    • /
    • 2007
  • In this research, Rayleigh instability of gas-liquid flow in annular pipe is studied in film boiling using viscous potential flow. Viscous potential flow is a kind of approximation of gas-liquid interface considering velocity field as potential including viscosity. A dispersion relation is obtained including the effect of heat and mass transfer and viscosity. New expression for dispersion relation in film boiling and critical wave number is obtained. Viscosity and heat and mass transfer have a stabilizing effect on instability and its effect appears in maximum growth rate and critical wave number. And the existence of marginal stability region is shown.

  • PDF

Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate (용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험)

  • Moon, C.G.;Bang, G.S.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

Analysis of Thermal Stresses During Solidification Process Using FVM/FEM Techniques (유한체적법과 유한요소법을 이용한 응고과정에서의 열응력해석)

  • 이진호;황기영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1009-1018
    • /
    • 1994
  • An attempt is made to develop a kind of hybrid numerical method for computations of the thermal stresses during a solidification process. In this algorithm, the phase-change heat transfer analysis is perrformed by a finite volume method(FVM) and the thermal stress analysis in a solidifying body by a finite element method(FEM). The temperatures at the grid points calculated in the heat transfer analysis are transferred to those of gauss points in elements by a bi-cubic surface patch technique for the thermal stress analysis. A hyperbolic-sine constitutive law is used to prescribe the inelastic strain rate of material. Results for the unidirectional solidification process of a pure aluminum are compared with those of others and shows good agreement.

Improved Multi-band Transfer Matrix Method for Calculating Eigenvalues and Eigenfunctions of Quantum Well and Superlattice Structures

  • Kim, Byoung-Whi;Jun, Yong-Il;Jung, Hee-Bum
    • ETRI Journal
    • /
    • v.20 no.4
    • /
    • pp.361-379
    • /
    • 1998
  • We present an improved transfer matrix algorithm which can be used in solving general n-band effective-mass $Schr{\ddot{o}}dinger$ equation for quantum well structures with arbitrary shaped potential profiles(where n specifies the number of bands explicitly included in the effective-mass equation). In the proposed algorithm, specific formulas are presented for the three-band (the conduction band and the two heavy- and light-hole bands) and two-band (the heavy- and light-hole bands) effective-mass eigensystems. Advantages of the present method can be taken in its simple and unified treatment for general $n{\times}n$ matrix envelope-function equations, which requires relatively smaller computation efforts as compared with existing methods of similar kind. As an illustration of application of the method, numerical computations are performed for a single GaAs/AlGaAs quantum well using both the two-band and three-band formulas. The results are compared with those obtained by the conventional variational procedure to assess the validity of the method.

  • PDF

A Numerical Study on the Phase-change Heat transfer problem in Cryosurgery (냉동수술시 수반되는 상변화 열전달 문제에 대한 수치해석적 연구)

  • 김동혁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.162-170
    • /
    • 1996
  • A numerical study on the Stefan problem occurred in cryosurgery is performed. Crank-Nicholson type finite difference algorithm based on the enthaly method is adapted to solve the phase change problem in this study. As it is a moving boundary problem, special emphasis is put on the estimation of the freezing front location. Two cases selected here are freezings of human tissue by disk type cryoprobe and by hemispherical one. In both cases, the heat flows are considered to be one dimensional. The calculated results using enthalpy method are compared with those using the program TRUMP and with Neumann's solution. These results agree guite well with each other. While it is pretty difficult to get accurate freezing front location by TRUMP due to the so- called "phase change knee" occured during the phase change, the algorithm based on the enthalpy method is proved to be very powerful to cope with this kind of problem.f problem.

  • PDF

Heat Transfer Analysis of a Coil-Typed LPG Vaporizer with an Electrically Heating Water Bath (전열온수식 LPG 기화기의 열전달 해석)

  • Choi, Sung-Joon;Kwon, Jeong-Rock;Kim, Kwang-Seok;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.19-25
    • /
    • 2007
  • The heat transfer phenomena in a coil-typed LPG vaporizer with a hot water bath employed an electrical heating system were experimentally analyzed. The heat energy is initially used to sensible heat region to heat LPG and then is done to latent heat region to vaporize LPG and to heat up the vaporized gas. A two-phase flow region could be found from periodic temperature fluctuations, and only sensible heat effect was found after passing through the region. The overall heat capacity was defined as multiplying the overall heat transfer coefficient by the heat transfer area and we found a correlation employing the heating water temperature and LPG flow rate. The results of this work can effectively be applied for the design of field scale LPG vaporizers in the near future because they can predict the features of heat transfer on a kind of coil type LPG vaporizer.

  • PDF

The Effect of international management activity and e-business on knowledge management (국제경영활동과 e-비즈니스가 지식경영에 미치는 영향)

  • Kim, Seong Ho;Hong, Ho Yeol
    • Knowledge Management Research
    • /
    • v.6 no.1
    • /
    • pp.33-69
    • /
    • 2005
  • Recently, knowledge management and E-business are very important issues in academic and business fields. Research questions related with these issues are which factors stimulate knowledge management. Another question is whether knowledge management is related to E-business. To answer these questions a research model was proposed. The data were collected from 90 manufacturing firms in Korea. Appropriate research methodologies were employed for analysis. Results found that the degree of firm's internalization, diversity of domestic management activities and learning orientation affect knowledge aquisition and transfer. Knowledge aquisition and transfer facilitate knowledge application, resulting in new product development, cost reduction and technology differentiation. Knowledge management is a kind of process. This result, therefore, confirms what previous literature predicted.

  • PDF