서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

토양의 이온화영역에서 소규모 접지전극의 과도접지임피던스 특성 분석 (Characteristics Analysis of Transient Impedances of Small-sized Ground Electrodes in a Ionization Region of Soil)

  • 유앙우;엄주홍;조성철;이태형;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.78-84
    • /
    • 2009
  • 본 논문은 토양의 방전 영역에서 소규모 접지전극의 과도접지임피던스의 측정결과를 제시한다. 접지전극 주변에서 이온화 특성을 사실적으르 분석하기 위해서 세 가지 형상의 접지전극을 실외에 설치하고, 고전압 임펄스 발생기를 사용하여 시험전류를 인가하였다. 정지전극에서 대지로 흐르는 전류와 응답 전압을 분석한 결과, 접지전극 주변의 이온화는 높은 대지저항률률의 토양에서 접지임피던스 감소에 기여하며 대지전위상승을 효과적으로 제한하는 것이 확인된다. 하지만 낮은 대지저항률의 토양에서는 이온화 임계전계강도가 작아서 전극 형상이 과도접지임피던스에 거의 영향을 주지 못한다. 그리고 전극형상에 따른 실험결과, 판전극보다 침부봉전극이 이온화 영역 전압범위 내에서 과도접지임피던스 저감에 보다 효과적이다.

지중 전력선 통신채널의 특성 해석 (An Analysis of Characteristics of Underground Power line Communication Channel)

  • 엄기환;신재호;이승준
    • 대한전자공학회논문지TC
    • /
    • 제48권5호
    • /
    • pp.40-45
    • /
    • 2011
  • 본 논문에서는 광대역 지중 전력선 통신 모뎀 및 네트워크 기술개발을 위하여 실제측정을 통해 지중 전력선 통신채널의 특성을 해석하였다. 지중 배전선로의 길이 및 구조물에 따른 지중 배전선로의 광대역 전력선 통신채널의 감쇠 량을 측정하기 위해 신호발생기, 스펙트럼 분석기, 비접촉식 커플러 등을 이용하여 채널 측정 시스템을 구성하였다. 실증시험을 위해 시험선로 내 단일 선로로서 가장 긴 고압 선로 두 곳을 선택하고, 그 채널상의 노이즈 특성 및 신호감쇠 레벨을 측정하였다. 측정결과 통신성능을 매우 떨어뜨릴 수 있는 임펄스 노이즈가 존재하는 것을 확인하였으며, 장거리 선로의 경우 선로 길이에 의한 고주파 감쇠가 나타나는 것으로 확인하였다.

서지전압에 대한 50[A]용 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages)

  • 이승칠;장석훈;이복희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권5호
    • /
    • pp.44-52
    • /
    • 1997
  • 반도체와 IC를 포함한 전자회로는 서지 전압 및 전류에 대해 매우 취약하다. 따라서 전자회로와 교류전원선로에 서지보호장치가 널리 사용되고 있다. 이들 서지보호장치의 동작에 의해 누전 차단기가 오동작 할 수 있으며, 누전 차단기의 오동작에 의한 교류전원의 차단은 전자.정보화 시스템의 운전효율 및 신뢰성의 저하와 경제적인 손실 등과 같은 단점을 초래한다. 본 연구의 목적은 서지 전압에 대한 누전 차단기의 오동작 특성을 조사하는 것이다. 10〔kV〕의 1.2/50〔$\mu\textrm{s}$〕서지전압발생기를 제작하였으며, 한국공업규격 KS C 4613의 시험조건과 바리스터를 포함하는 모의 시험회로 조건에 대해 서지 전압을 인가하였을 때 누전 차단기의 오동작 특성을 측정하였다. 그 결과, 서지 전압과 표류정전용량이 증가함에 따라 누전 차단기의 영상전류의 피크값은 증가하였다. 본 연구에서 사용된 모든 누전 차단기는 KS C 4613에 규정된 뇌임펄스 부동작 시험조건에는 적합하였다. 그러나 바리스터를 삽입한 시험회로 조건에서는 단지 1종의 시료를 제외하고 모두 오동작하였다. 서지보호장치를 가지고 있는 교류전원선로에 설치된 누전차단기는 오동작할 가능성이 매우 높다.

  • PDF

Failure Prediction of Metal Oxide Varistor Using Nonlinear Surge Look-up Table Based on Experimental Data

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.317-322
    • /
    • 2015
  • The metal oxide varistor (MOV) is a major component of the surge protection devices (SPDs) currently in use. The device is judged to be faulty when fatigue caused by the continuous inflow of lightning accumulates and reaches the damage limit. In many cases, induced lightning resulting from lightning strikes flows in to the device several times per second in succession. Therefore, the frequency or the rate at which the SPD is actually exposed to stress, called a surge, is outside the range of human perception. For this reason, the protective device should be replaced if it actually approaches the end of its life even though it is not faulty at present, currently no basis exists for making the judgment of remaining lifetime. Up to now, the life of an MOV has been predicted solely based on the number of inflow surges, irrespective of the magnitude of the surge current or the amount of energy that has flowed through the device. In this study, nonlinear data that shows the damage to an MOV depending on the count of surge and the amount of input current were collected through a high-voltage test. Then, a failure prediction algorithm was proposed by preparing a look-up table using the results of the test. The proposed method was experimentally verified using an impulse surge generator

Implementation of sigma-delta A/D converter IP for digital audio

  • Park SangBong;Lee YoungDae
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.199-203
    • /
    • 2004
  • In this paper, we only describe the digital block of two-channel 18-bit analog-to-digital (A/D) converter employing sigma-delta method and xl28 decimation. The device contains two fourth comb filters with 1-bit input from sigma­delta modulator. each followed by a digital half band FIR(Finite Impulse Response) filters. The external analog sigma-delta modulators are sampled at 6.144MHz and the digital words are output at 48kHz. The fourth-order comb filter has designed 3 types of ways for optimal power consumption and signal-to-noise ratio. The following 3 digital filters are designed with 12tap, 22tap and 116tap to meet the specification. These filters eliminate images of the base band audio signal that exist at multiples of the input sample rate. We also designed these filters with 8bit and 16bit filter coefficient to analysis signal-to-noise ratio and hardware complexity. It also included digital output interface block for I2S serial data protocol, test circuit and internal input vector generator. It is fabricated with 0.35um HYNIX standard CMOS cell library with 3.3V supply voltage and the chip size is 2000um by 2000um. The function and the performance have been verified using Verilog XL logic simulator and Matlab tool.

  • PDF

바리스터와 LC필터를 조합한 교류 전원용 서지보호장치 (Surge Protective Device Combined with Varistor and LC Filter on AC Power Circuits)

  • 이복희;이경옥;안창환;이승칠;박정웅
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권4호
    • /
    • pp.109-116
    • /
    • 1997
  • I본 논문은 교류 전원용 바리스터와 LC필터를 조합한 서지 보호장치에 대해서 기술하였다. 지금까지 교류 전류용 서지 보호장치로써 바리스터만이 주로 사용되어 왔으나, 이것은 급상승하고 높은 잔류전압 때문에 보호되어야 할 장비에 해로운 결과를 초래하는 경우도 있다. 따라서 본 연구에서는 교류 전원용 서지 보호장치의 차단 성능을 향상시키기 위하여 바리스터와 LC필터로 구성된 조합형 서지 보호장치를 설계.제작하였다. 그리고 서지 보호장치의 동작특성과 차단 성능의 분석에 대한 실험을 1.2/50[$\mu\textrm{s}$] 임펄스 발생기를 적용하여 수행하였다. 결론적으로 본 연구에서 제시한 조합형 서지보호장치는 서지 전압을 더욱 낮게 제한할 수 있고, dV/dt의 값을 매우 낮은 값으로 감소시키며, LC필터에 의한 출력단의 고주파 전압을 효과적으로 감쇠시킬수 있기 때문에 전자시스템의 손상과 전도를 더욱 더 효과적으로 방지할 수 있다.

  • PDF

축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석 (Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model)

  • 김점식;김도영;박용범;권신원;길경석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

지중전력선 통신채널 측정에 의한 특성해석 (The Analysis of Underground Power Line Communication Channel Characteristics by Measurements)

  • 신동환;최정연;이승준;우희곤;신재호;엄기환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.86-89
    • /
    • 2009
  • 본 논문에서는 광대역 전력선 통신 모뎀 및 네트워크 기술개발을 위하여 실측 실험을 통한 지중 전력선 통신채널의 특성을 해석한다. 지중 배전선로의 길이 및 구조물에 따른 지중 배전선로 광대역 전력선통신 채널상의 감쇠 량을 측정하기 위해 신호발생기, 스펙트럼 분석기, 비접촉식 커플러 등을 이용하여 채널 측정 시스템을 구성하였다. 실증시험은 시험선로 내 단일 선로로서 가장 긴 고압 선로 두 곳을 선택하여 채널상의 노이즈 측정 및 신호감쇠 레벨을 측정하였다. 측정결과 통신성능을 매우 떨어뜨릴 수 있는 임펄스 노이즈가 존재하는 것을 확인하였으며, 장거리 선로의 경우 선로 길이에 의한 고주파 감쇠가 나타나는 것으로 확인하였다.

  • PDF