• Title/Summary/Keyword: Impression

Search Result 1,564, Processing Time 0.027 seconds

The Analysis of Wearers' Impression to Combination of their Body Type with Neutral Tone Wear - focused on Pants- (체형과 무채색 톤조합에 따른 의복 착용자의 인상 평가 -팬츠차림을 중심으로-)

  • Paeng, Suk-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.15 no.4
    • /
    • pp.631-646
    • /
    • 2006
  • The purpose of this study is to find out its effect on wearers' impression formated by combination of their body type with neutral tone clothing. The experimental materials developed for this study are a set of responses to stimulus in scales(7-point semantic). 45 pictures used as stimulus are, through computer simulation, manipulated to five wearers' body type and nine neutral tone wear. The subjects are 276(?) female undergraduate students in Kyung-nam area. Factors on wearers' impression suggested as responses to the stimulus consist of 5 different demensions (Tenderness, Cuteness, Attractiveness, Elegance, Intrepidity). The results of this study are as follows: first, combination of their body type with neutral tone wear significantly affects the formation of wearers' impression in the factor of Tenderness, Attractiveness, and Intrepidity (?); to the factor of Attractiveness, wearers' body type is rather more related than wearers' neutral tone wear is. Second, the harmony of their body type with neutral tone wear has a significant effect on wearers' impression in the factor of Cuteness. According to those results, the combination of wearers' body type with neutral tone wear has significant effects on the formation of wearers' impression.

  • PDF

Empirical study of alginate impression materials by customized proportioning system

  • Kurtulus, Karani;Tufekci, Kenan
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.372-379
    • /
    • 2016
  • PURPOSE. Alginate mixers available in the market do not have the automatic proportioning unit. In this study, an automatic proportioning unit for the alginate mixer and controller software were designed and produced for a new automatic proportioning unit. With this device, it was ensured that proportioning operation could arrange weight-based alginate impression materials. MATERIALS AND METHODS. The variation of coefficient in the tested groups was compared with the manual proportioning. Compression tension and tear tests were conducted to determine the mechanical properties of alginate impression materials. The experimental data were statistically analyzed using one way ANOVA and Tukey test at the 0.05 level of significance. RESULTS. No statistically significant differences in modulus of elastisity (P>0.3), tensional/compresional strength (P>0.3), resilience (P>0.2), strain in failure (P>0.4), and tear energy (P>0.7) of alginate impression materials were seen. However, a decrease in the standard deviation of tested groups was observed when the customized machine was used. To verify the efficiency of the system, powder and powder/water mixing were weighed and significant decrease was observed. CONCLUSION. It was possible to obtain more mechanically stable alginate impression materials by using the custom-made proportioning unit.

A study on Common Errors in Digital Impressions: (An Example of CEREC$^{(R)}$ AC) (디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC$^{(R)}$ AC의 사례 중심으로 -)

  • Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC$^{(R)}$ AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC$^{(R)}$ AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.

The Impression Evaluation of the Dress's Wearer in Relation to Hue, Tone, Skirt Width and Length (색상과 톤, 스커트 폭·길이에 따른 원피스드레스 착용자의 인상평가)

  • Choi, Su-Kyung;Kang, Kyung-Ja
    • Fashion & Textile Research Journal
    • /
    • v.6 no.4
    • /
    • pp.447-454
    • /
    • 2004
  • The purpose of this study is to identify the effect of four clothing cues(hue, tone, skirt width, and skirt length of dress) on female impressions. The experimental materials developed for this study are a set of stimuli and response scales. The Stimuli are 40 color pictures manipulated with four clothing cues by drawing. The 7-point scale designed for visual evaluation of female impression formation includes 29 bipolar adjectives. The subjects were 240 undergraduate female students in Jinju city. The results of this study are as follow: As analyzing the impression of the female figure by the hue, tone, skirt width, and length, five factors including ability activity, elegance, attractiveness, concentration of attention, and tenderness were identified. Among these factors, ability activity and elegance were proved to be more important. Each impression of hue and tone with skirt width length have significant effects on concentration of attention, and tenderness. We can express various impressions by diversifying hue and tone. Each impression of skirt width length with hue and tone have significant effects on ability activity and elegance.

The Impression Evaluation d the Dress's Wearer in Relation to Neutral Tone, Skirt Width and Length Variation (무채색의 톤과 스커트 폭.길이 변화에 따른 원피스드레스 착용자의 인상평가)

  • Chio, Su-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.2
    • /
    • pp.317-328
    • /
    • 2004
  • The purpose of this study was to identify the effect of three clothing cues(neutral tone, skirt width, and skirt length of dress) on the impressions of females. The experimental materials developed for this study were a set of stimuli and response scales. The stimuli were 20 color pictures manipulated with three clothing cues by drawing. The 7-point scale designed for visual evaluation of impression formation about females included 29 bipolar adjectives. The subjects were 240 undergraduate female students in Chinju city. The results of this study were as follows: By analyzing the impression of female figures by neutral tone, skirt width, and length, five factors including ability.activity, elegance, attractiveness, concentration of attention, and tenderness were identified. Among these factors, ability.activity and elegance were proved to be more important. Each impression of neutral tone with skirt width. length have significant effects on tenderness. Each impression of skirt width.length with neutral tone have significant effects on ability.activity.

  • PDF

IMPRESSION-DRIVEN DESIGN SCHEME FOR A CLASS OF 3D OBJECTS BASED ON MORPHABLE 3D SHAPE MODEL, AND ITS AUTOMATIC BUILDUP BY SUPPLEMENTARY FEATURE SAMPLING

  • Inaba, Yoshinori;Kochi, Jumpei;Ishi, Hanae;Gyoba, Jiro;Akamatsu, Shigeru
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.606-611
    • /
    • 2009
  • This paper describes a method for achieving a novel design within a class of 3D objects that would create a preferred impression on users. Physical parameters of the 3D objects that might strongly contribute to their visual impressions are sought through computational investigation of the impression ratings obtained for learning samples. "Car body" was selected as the class of 3D objects to be investigated. A morphable 3D model of car bodies that describes the variations in appearance using a smaller number of parameters was obtained. Based on each car body's rating for the impression of speediness obtained by paired comparison, the visual impression was transformed by manipulating the parameters defined in the morphable 3D model. The validity of the proposed method was confirmed by psychological experiments. A new scheme is also proposed to properly re-sample a novel object of a peculiar shape so that such an object could also be represented by the morphable 3D model.

  • PDF

The Impression Evaluation of the Hat's Wearer According to Types of Hat design, Hair-style and Hair-length (모자유형과 헤어스타일 및 길이변화에 따른 모자착용자의 인상평가)

  • Jeong Su-Jin;Jeong Hae-Son;Kang Kyung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.7 no.3
    • /
    • pp.129-144
    • /
    • 2005
  • The purpose of this research was to find out the effect of hair-style(straight and wave), hair-length(short, medium and iong), and type of hat design(no-hat, beret, cloche, bowler and capeline) on the impressions of hat's wearer . The experimental materials developed for this study were a set of stimulus and response scales(7-point scale semantic). Thirty stimuli color pictures of various combination of hair length, hair style, and type of hat design were manipulated by computer drawing. The subjects were 360 undergraduate students in Seoul, Kyunggi and Kyungnam. The result of this study can be summarized as follows; Impression factor of the stimulus consisted of the 5 different dimensions (attractiveness, gracefulness, brightness, visibilty, cuteness). Each impression of type of hat design, along with hair-style, hair-length had significant effects on gracefulness, visibilty and cuteness. Each impression of hair-style, hair-length, along with type of hat design had significant effects on gracefulness, brightness, visibilty and cuteness. Thus type of hat design, hair-style and hair-length have a significant influence on the impression evaluation of hat's wearer.

  • PDF

An alternative impression technique based on McLean's functional impression concept (McLean의 기능 인상법에 기반한 새로운 인상채득법)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • In this case report, an alternative impression technique for fabricating removable partial dentures was used in a patient with very few remaining teeth. In this technique, an individual tray was made on the cast, which was made by relining interim denture and taking overimpression with irreversible hydrocolloid according to McLean's functional impression concept. This method showed the following advantages: the no need for border molding with modeling compound, time saving for denture impression without overextension and accurate seating of the individual tray.

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

COMPARISON OF STONE SURFACE POROSITIES CAUSED BY HYDROGEN GAS FROM ADDITION SILICONE IMPRESSION MATERIALS (부가 중합형 실리콘 인상재에서 발생하는 수고 기체가 경석고 표면에 미치는 영향)

  • Yoo, So-Jeong;Lee, Keun-Woo;Kim, Kyeung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.349-362
    • /
    • 1996
  • To determine the factors to affect on stone surface porosities produced from hydrogen gas of additional silicone, both putty and syringe type of 7 commercially different additional silicone impression materials(Blend-A-Scon, Correct VPS, Exaflex, Express, Extrude, Provil, Reprosil) were chosen and NewFujirock(GC) was poured into the impressions of detail-reproducing test block at 1, 15, 30, 45, 60 minutes after the impression materials had set and 4 specimens were made for each pouring time, each type of impression material, and each consisency and So, 280 specimens were made in total. The number of surface porosities of same area($2826 mm^2$) which were typically caused by hydrogen gas using the stereoscope(X 7.5) by two observers. Comparison of putty-syringe type and among the impression materials are tested by Kruscal-Wallis method and Mann-Whitney method(p<0.05). The results are as follows. 1. The number of porosities decreased as the pouring time of stone was delayed on both putty and syringe type of additional silicone materials. 2. The putty type significantly produced more porosities than syringe type except for the group of Reprosil.(p<0.05). 3. In case of putty type, the number of porosities increased as following order. Reprosil / Blend-A-Scon and Provil / Correct VPS and Extrude / Express and Exaflex. 4. In case of syringe type, Blend-A-Scon and Extrude produced no porosity and Exaflex and Provil at 30 minites, but Express produced porosities even at 60 minutes and the most. Additional silicone impression material releases hydrogen gas, and that fact can make the resulting die stone model useless. So, to minimize these adverse effects, it is desirable not to expose putty type of additional silicone on critical impression surface because putty type has a tendency to produce more porosities than syringe type. And it is important to have sufficient time before pouring the stone on impression because porosities produce less as time passes after setting of impression material. Also, there are differences among 7 additional silicone impression materials, so it is desirable to choose adequate brand of additional silicone for good laboratory work.

  • PDF