• 제목/요약/키워드: Implantable

검색결과 310건 처리시간 0.033초

생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발 (Development of a transcutaneous system for implantable bio-signal measurement)

  • 이승하
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.

Slotted Implantable Patch Antenna for ISM Band Application and Its Usage in WiMAX with an I-Shaped Defected Ground Structure

  • Ayubi, Adil Al;Sukhija, Shikha;Sarin, Rakesh Kumar
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권6호
    • /
    • pp.359-363
    • /
    • 2017
  • A slotted implantable patch antenna with microstrip feeding is proposed for industrial, scientific, and medical band applications. The result is verified by implanting the antenna in animal tissue. Further, by varying the ground width and introducing a defect into the ground structure, the antenna becomes applicable for worldwide interoperability for microwave access operations. A simulation is performed using Empire XCcel software. An Agilent vector network analyzer is used for analyzing the return loss performance. Simulated and measured results are compared. Antennas with and without defected ground structure both have key advantages including low profile, desirable return loss, good impedance matching and required bandwidth.

모터구동형 완전이식 인공심장에서 전류파형의 분석에 의한 심박출량 자동제어 알고리즘의 개발 (A Study On the Automatic Cardiac Output Control Without Pressure Sensors for the motor-driven Totally Implantable TAH Using Motor-Current Waveform Analysis)

  • 최원우;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.130-135
    • /
    • 1992
  • In this paper a new cardiac output control method without pressure sensors is presented for the rotor-driven totally implantable TAH using motor-current wavelet analysis. Theoretical analysis and mock circulation system experiment results show that cardiac output of TAH, which is indeperdent of afterload and sensitively dependent to preload, is well controlled for the independently variable preload.

  • PDF

비육우에서 이식형 bovine somatotropin 지속성 제형의 blood profile test (Blood profile test of sustained release formula of implantable bovine somatotropin in steers)

  • 김남중
    • 대한수의학회지
    • /
    • 제49권1호
    • /
    • pp.9-15
    • /
    • 2009
  • The present study was carried out to examine the sustained release effect of the implantable bovine somatotropin (SRI-BST) formula. In the blood profile test in steers, the bovine somatotropin concentration in serum by radioimmunoassay showed the peak concentration on the first day after the implantation of the SRI-BST formula, and concentration proceeded for 5 days (p < 0.05). The insulin-like growth factor-1 concentration showed the peak concentration on the seventh day after implantation of the SRIF-BST formula, and concentration proceeded for 10 days (p < 0.05). The glucose showed the peak concentration on the first day after implantation of the SRI-BST formula, and concentration continued for 3 days (p < 0.05). The blood urea nitrogen showed the lowest concentration on the third day after implantation of the SRI-BST formula, and concentration continued for 7 days (p < 0.05). These results proved that the SRIF-BST formula was the sustained release effects in steers.

An Implantable Antenna for Wireless Body Area Network Application

  • Kim, Ui-Sheon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.206-211
    • /
    • 2010
  • In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimensions of the pacemaker system, including the antenna element, are $42{\times}43.6{\times}11$ mm. When the antenna is embedded in pig tissue, its $S_{11}$ value is -10.94 dB at 403 MHz and the -10 dB impedance bandwidth of the antenna is 6 MHz (399~406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a flat phantom, its specific absorption ratio (SAR) value is 0.038 W/kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).

이식형 중이 보청기에 적용 가능한 Si 탄성체로 구현된 전자기 진동 트랜스듀서 (Electromagnetic Vibration Transducer Using Silicon Elastic Body For Implantable Middle Ear Hearing Aid Applications)

  • 이기찬;이세규;박세광;조진호;이상흔
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권10호
    • /
    • pp.583-588
    • /
    • 2000
  • This paper presents the design and fabrication of micro electromagnetic vibration silicon elastic body characterized with small size, high efficiency and selective frequency bandwidth for Bio-MENS applications, such as implantable middle ear hearing aid. The presented electromagnetic vibration transducer that composed of wounded coil, permanent magnet and 4-beam cross type elastic body is fabricated by using of micromachining technology. The fabricated transducer has experimental characteristics, that is 5 nm/mA of an energy trasfer rate at the frequency range of 100∼2800 Hz. It has a size of $2{\times}2{\times}2.5\;mm^3$.

  • PDF

심부 조직 인체 삽입용 세 가지 밴드 안테나 (A Triple Band Deep-Tissue Antenna for Biomedical Implants)

  • 유형석
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.383-386
    • /
    • 2017
  • In this study, we introduce a triple-band flexible implantable antenna that is tuned by using a ground slot in three specific bands, namely Medical Implanted Communication Service (MICS: 402-405 MHz) for telemetry, the midfield band (lower gigahertz: 1.45-1.6 GHz) for Wireless Power Transfer (WPT), and the Industrial, Scientific and Medical band (ISM: 2.4-2.45 GHz) for power conservation. This antenna is wrapped inside a printed 3D capsule prototype to show its applicability in different implantable or ingestible devices. The telemetry performance of the proposed antenna was simulated and measured by using a porcine heart. From the simulation and measurement, we found that use of a ground slot in the implantable antenna can improve the antenna performance and can also reduce the Specific Absorption Rate (SAR).

Current Development in Bio-implantable Sensors

  • Swarup, Biswas;Yongju, Lee;Hyojeong, Choi;Hyeok, Kim
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.403-410
    • /
    • 2022
  • Flexible and wearable sensing technologies have emerged as a result of developments in interdisciplinary research across several fields, bringing together various subjects such as biology, physics, chemistry, and information technology. Moreover, various types of flexible wearable biocompatible devices, such customized medical equipment, soft robotics, bio-batteries, and electronic skin patches, have been developed over the last several years that are extensively employed to monitor biological signals. As a result, we present an updated overview of new bio-implantable sensor technologies for various applications and a brief review of the state-of-the-art technologies.

완전 이식형 인공중이용 마이크로폰의 위치 결정을 위한 물리적 귀 모델의 구현 (Implementation a Physical Ear Model for Determinating Location of the Microphone of Fully Implantable Middle Ear Hearing Device)

  • 김동욱;성기웅;임형규;김민우;정의성;이장우;이명원;이정현;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.27-33
    • /
    • 2009
  • 일반적으로, 완전 이식형 인공중이의 이식형 마이크로폰은 측두골 부근에 이식되어진다. 이 경우, 마이크로폰의 진동막이 외부 충격이나 생체 노이즈의 영향 받을 수 있으며 이런 문제를 해결하기 위하여 이식용 마이크로폰을 외이도 내에 이식하는 방법을 고려할 수 있다. 그러나 이소골에 이식된 진동 트랜스듀서에 의해서 고막으로부터 외이도 방향으로 음향 반향이 발생할 가능성이 있다. 본 논문에서는 사람의 귀와 유사한 특성을 가지는 귀 모델을 제작하여 프로브 마이크로폰의 위치를 변경해가며 외이도의 음향 반향을 측정하였고 실험결과를 통하여 외이도 내에서의 마이크로폰의 이식 위치를 추정해 보았다. 분석 결과 외이도에 마이크로폰을 이식할 경우 고막에서 멀어질수록 반향 신호가 감소함을 확인할 수는 있었으나, 반향 신호를 완전히 제거할 수 없기 때문에 외이도에 마이크로폰을 이식하기에는 부적합한 것으로 예상된다.

  • PDF

완전 거치형 정맥도관의 임상분석 (Clinical Review of Totally Implantable Venous Catheter)

  • 김정태;오태윤
    • Journal of Chest Surgery
    • /
    • 제40권10호
    • /
    • pp.691-695
    • /
    • 2007
  • 배경: 중심정맥 도관은 1979년 처음 사용된 이래로 암환자의 치료에 있어 많은 편의를 제공하였다. 이에 본원 흉부외과에서는 완전 거치형 정맥도관의 임상 양상 및 사용에 따른 합병증 등을 분석하여 향후 치료에 도움이 되고자 본 연구를 하였다. 대상 및 방법: 2004년 11월부터 2006년 2월까지 완전 거치형 정맥도관 시술을 받은 100명의 환자를 대상으로 후향적 연구를 하여 다음과 같은 결과를 얻었다. 결과: 완전 거치형 정맥 도관 시술의 삽입정맥으로는 우측 쇄골하정맥 삽입이 74예(74%)였으며 좌측쇄골하 정맥(21예, 21%), 우측 경정맥(3예, 3%), 좌측 경정맥(1예, 1%)을 사용하였으며 1예에서는 우측 대퇴정맥을 사용하였다. 초기 합병증으로는 위치 이상이 5예(5%)와 동맥천자한 경우 5예 있었다. 만기 합병증으로는 쇄골하 정맥 혈전 형성이 한 예 있어 현재 항응고제 복용중이며 pinch off 증후군이 2예 있었다. 그 외의 초기 또는 만기 합병증은 없었다. 결론: 완전 거치형 도관의 사용은 합병증의 발생률은 낮고 비교적 안전한 방법이지만 감염, 혈전 형성, 도관의 절단 등은 장기간 사용시 나타날 수 있는 합병증으로 초기에 진단 및 치료가 된다면 더 큰 합병증을 예방할 수 있다.