• 제목/요약/키워드: Implant type

검색결과 800건 처리시간 0.028초

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구 (Analysis of thermal changes in bone by various insertion torques with different implant designs)

  • 김민호;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.168-176
    • /
    • 2011
  • 연구 목적: 임플란트 식립시에 발생할 수 있는 열변화는 임플란트의 실패를 초래할 수 있다. 식립토크에 따른 열변화 양상을 파악함으로 임플란트의 형태에 따른 차이점과 적절한 식립토크가 어떤 것인지 파악하고자 한다. 연구 재료 및 방법: 실험재료로는 두께 15 - 20 mm의 소 견갑골을 가로 35 mm, 세로 40 - 50 mm 크기가 되도록 골편으로 자르고 이중에 피질골의 두께가 2 - 3 mm 되는 표본을 선정한 후 표본의 반을 $36.5^{\circ}C$ 수조에 실온 $25^{\circ}C$에 노출 시켜 내부 온도는 평균 $36.5^{\circ}C$, 표면온도 $28^{\circ}C$가 되도록 설계하였다. $4.5{\times}10\;mm$의 외부육각을 가지는 Br${\aa}$nemark 형태의 임플란트와 $4.8{\times}10\;mm$의 Microthread 형태를 지니는 내부연결 형태의 임플란트를 과도한 식립토크로 식립하고 온도 측정은 계측점에서 0.2 mm 이내에 열전대를 위치시켜 기록하였다. 삼차원유한요소 분석은 골의 형태를 가로 4 cm, 세로 4 cm, 높이 2 cm의 직육면체로 가정하고, 직육면체 윗면에서 2 mm까지를 피질골, 그 아랫부분을 해면골이라고 가정하였다. 마찰열은 매식이 종료된 상황에서 골에 남는 cavity 모양을 기초로 경계조건을 부여하였다. CAD 프로그램인 SolidWorks 소프트웨어를 이용하였고, 이를 유한요소 구조해석용 프로그램인 Abaqus 6.9-1로 불러들여 해석하였다. 결과 및 결론: In vitro실험에서 Microthread type의 임플란트가 상대적으로 더 높은 최고점 온도를 보여주고 있으며 이는 임플란트의 형태에 따른 마찰열 발생이 주요 원인으로 보인다. 유한요소분석을 통해 살펴본 결과 Br${\aa}$nemark 형태의 임플란트의 경우 50 Ncm이상에서 Microthread를 가지는 형태의 경우에는 35 Ncm이상에서 Eriksson 등이 보고한 역치를 초과하는 온도가 발생하였다. 이를 통해 볼 때 Microthread type 이 식립토크에 따른 온도 증가가 더 민감함을 알 수 있다. 실험결과를 통해서 서로 다른 형태의 임플란트 식립시에 임플란트의 형태에 따라 적절한 삽입토크를 부여하는 것이 성공적인 임플란트 시술에 중요한 요소 중에 하나임을 알 수 있었다. 특히 Microthread를 갖는 임플란트 형태는 높은 초기고정성을 얻을 수 있다는 장점이 있는 반면 과도한 식립 토크로 인한 열 손상 가능성을 가질 수 있으므로 골량과 골질의 신중한 평가와 적절한 수술기법이 필요할 것으로 생각된다.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

외측연결형 임플란트 고정체의 경부 디자인이 임플란트 주위조직에 미치는 영향에 대한 전향적 예비 임상연구 (Effect of neck design on peri-implant tissue responses in external connection type implant : a prospective pilot clinical study)

  • 배은빈;이소현;전영찬;강은숙;박상례;이진주;허중보
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.766-776
    • /
    • 2017
  • This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with 's' shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant survival rate, marginal bone resorption, bleeding, plaque, and complications were evaluated. The survival rate of NBS and BS group was 94.74% and 90.48%, respectively. There was no significant difference on marginal bone resorption, bleeding and plaque between the two groups (P>.05). Within the limits of the present study, implants with a concave neck design showed similar clinical results to implants with a straight neck design on the peri-implant tissue responses. Longitudinal clinical studies are necessary to confirm more effective clinical results.

  • PDF

Clinical evaluation of 3.0-mm narrow-diameter implants: a retrospective study with up to 5 years of observation

  • InKyung Hwang;Tae-Il Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • 제54권1호
    • /
    • pp.44-52
    • /
    • 2024
  • Purpose: This study aimed to evaluate the clinical outcomes of a single type of narrow-diameter implant (NDI) by investigating its survival rate and peri-implant marginal bone loss (MBL). In addition, variables possibly related to implant survival and MBL were investigated to identify potential risk factors. Methods: The study was conducted as a retrospective study involving 49 patients who had received 3.0-mm diameter TSIII implants (Osstem Implant Co.) at Seoul National University Dental Hospital. In total, 64 implants were included, and dental records and radiographic data were collected from 2017 to 2022. Kaplan-Meier survival curves and a Cox proportional hazard model were used to estimate the implant survival rate and to investigate the effects of age, sex, jaw, implant location, implant length, the stage of surgery, guided bone regeneration, type of implant placement, and the surgeon's proficiency (resident or professor) on implant survival. The MBL of the NDIs was measured, and the factors influencing MBL were evaluated. Results: The mean observation period was 30.5 months (interquartile range, 26.75-45 months), and 6 out of 64 implants failed. The survival rate of the NDIs was 90.6%, and the multivariate Cox regression analysis showed that age was associated with implant failure (hazard ratio, 1.17; 95% confidence interval, 1.04-1.31, P=0.01). The mean MBL was 0.44±0.75 mm, and no factors showed statistically significant associations with greater MBL. Conclusions: NDIs can be considered a primary alternative when standard-diameter implants are unsuitable. However, further studies are required to confirm their long-term stability.

골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析) (A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type)

  • 이무건;조성암
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.120-147
    • /
    • 1994
  • 저자는 가공의치에서 임플란트와 치아간의 보철물 연결형태와 나사형 및 원통형 임플란트에서 그 형태의 차이가 주위 골조직의 응력분산에 어떤 영향을 미치는지 알아보기 위해 임플란트와 지대치를 고정성 및 반고정 성 가공의 치로 연결하고 수평면에 대해 수직 및 25도 측방하중을 가하여 주위 골조직의 응력분산 양상을 3차원적 광탄성 실험을 통해 비교 분석한 바 다음과 같은 결론을 얻었다. 1) 나사형 임플란트에서는 수직 및 측방력에 대해 경부에 응력집중이 나타났다. 2) 나사형 임플란트와 치아를 가공의치로 연결했을 경우에는 임플란트의 경부와 지대치의 치경부 및 근단부에 응력집중이 나타났으며, 고정성 가공의치로 연결했을 때에는 지대치의 치경부에 반고정성 가공의치로 연결했을 때에는 임플란트 경부에 더 큰 응력집중이 나타났다. 3) 원통형 임플란트와 치아를 가공의치로 연결했을 경우에는 임플란트와 지대치의 근단부에 응력집중이 나타났으며, 고정성 가공의치로 연결했을 때에는 지대치의 근단부에 반고정성 가공의치로 연결했을 때에는 임플란트와 지대치의 경부에 더 큰 응력집중이 나타났다. 4) 임플란트와 치아를 가공의치로 연결했을 경우에는 고정성 및 반고정성 가공의치 양쪽 모두에서 원통형 임플란트보다 나사형 임플란트에서 지대치 주위의 응력분산이 더 균등하게 나타났다. 5) 나사형 임플란트 주위의 응력분산은 임플란트 두 개를 고정성 가공의치로 연결했을 때, 가장 균등한 것으로 나타났으며, 그 다음이 치아와 고정성 가공의치로 연결했을 때, 그 다음이 치아와 반고정성 가공의치로 연결했을 때, 그리고 임플란트 단독으로 사용했을 때 가장 불리한 것으로 나타났다.TEX>$45.4{\pm}16.6m$, Panavia는 $41.3{\pm}22.9m$, 그리고 All-Bond는 $151{\pm}82m$로 나타났다. 4. 인산 아연 세멘트와 Panavia는 All-Bond에 대해 통계학적 유의성 있는 차이를 나타내었으며(p<0.05)인산 아연 세멘트와 Panavia-EX사이에는 유의성 있는 차이가 없었다(p>0.05). 비교시 All-Bond & composite resin cement 군이 Z.P.C. 군보다 높게 나타났으나 통계학적 유의성은 없었다(P>0.05).않거나 더 적게 쓰고도 농사를 지을 수 있는 영농법 및 농약을 좀 더 안전하게 살포할 수 있는 방법의 개발, 고온에서도 착용하기 좋고 보호 성능이 좋은 보호구의 개발이 시급히 요구되며, 농약살포시 환기요령과 보호구 착용방법에 대한 교육 등의 강화도 고려되어야 할 것으로 생각된다. 둘째, 농부증 증상 중 흔한 증상들은 농작업 자세 및 과도한 노동에 기인되었을 가능성이 있으므로 신체에 부담을 줄일 수 있는 농기구를 개발하고, 주기적인 휴식 및 운동을 권장해 볼 만하다. 세째, 고혈압 유소견율이 15% 전후로 높으므로 고혈압 관리사업의 강화가 요구된다.는 의료분쟁을 줄일 수 있는 방안이 마련되어야 하고, 의료보험수가의 조정도 필요할 것이다.보호차원에서 정부의 중립적 의지가 있어야 할 것으로 생각된다.의 비율이 감소하였으나 본태성고혈압, 당뇨병, 폐결핵, 협심증 둥의 비율이 증가하였다. 일반외과의 경우에는 치핵, 항문열상, 종기 등의 비율이 감소하였고, 위암, 대장암, 담낭암 등의 비율은 증가하였다.

  • PDF

변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향 (Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture)

  • 윤미정;윤민철;엄태관;허중보;정창모
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.99-105
    • /
    • 2012
  • 연구 목적: 지금까지 성공적인 임플란트 치료를 위해 많은 연구가 진행되어 왔으며, 임플란트 주변 골 흡수 현상에 대한 연구는 매우 관심이 높은 분야 중 하나이다. 이에 본 연구에서는 삼차원 유한요소응력분석을 이용하여 변연골 흡수가 내측연결 임플란트 매식체의 기계적 안정성에 미치는 영향을 간접적으로 확인하고자 하였다. 연구 재료 및 방법: 악골에 식립된 내측연결 형태의 임플란트 매식체에 티타늄 소재의 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 삼차원 유한요소모형을 설계하였다. 0, 1, 2, 3 mm의 변연골 흡수 상태를 적용하고, 교합면 중심에서부터 3 mm 편측에 300 N의 수직 하중을 가하여 임플란트 매식체에 발생하는 최대 주 응력을 계산하였다. 결과: 유한요소분석결과 변연골 흡수에 따른 임플란트 매식체의 최대 주응력 분포는 유사한 양상을 보였으며, 임플란트 매식체 상단에서 가장 높은 응력 집중이 나타났다. 최대 주응력은 처음 1 mm 변연골 흡수를 가정하였을 때 가장 크게 증가하였고, 이후 변연골 흡수가 증가할수록 응력은 증가하였지만 응력 증가의 폭은 감소하는 경향을 보였다. 결론: 이러한 결과로부터 내측연결 임플란트에서 매식체 두께가 얇은 경부의 노출은 변연골 흡수로 인한 응력 증가에 가장 큰 원인임을 알 수 있었으며, 매식체의 변형, 균열 및 파절 등의 기계적 실패를 감소시키기 위해서는 이에 대한 외과적, 보철적 고려가 필요할 것으로 생각된다.

체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구 (Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force)

  • 이용우;장용훈
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

한국환자에 매식된 ITI 임플란트에 관한 조사 (An analysis of ITI implants placed in korean patients)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.361-370
    • /
    • 2002
  • The aim of this study was to analyze various data of 120 non-submerged ITI implants placed in 64 korean adults. The data were retrieved from patients' charts and registered in the computer and coded for a statistical analysis. The results revealed that the most common type of edentulism was a distal extension case, and the largest number of implants were placed in the mandibular first molar position. Implants were placed more frequently in mandibular, posterior position than maxillary, anterior position, respectively. With respect to the implant diameter and length, an implant with 4.1mm in diameter and more than 10mm in length was the most common. Since a molar position was the most prevalent position for implant placement in korean patients, clinicians should be careful about implant diameter which can resist a strong occlusal force expected in the molar position. In addition, the distance to the mandibular canal and the floor of maxillary sinus should be considered to avoid possible damages, such as nerve injury and sinus perforation in selecting a proper implant length.

임플란트의 즉시 기능에 관한 최신 지견 (Immediate Loading of Implants ; Recent Review)

  • 김윤상
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.191-204
    • /
    • 2005
  • Traditionally, the implant treatment require load-free healing period of at least 3 months in the mandible and 6 months in the maxilla. But this long healing period provides patients with the discomfort and economical trouble. Many experiments has been attempted for the outcome of such disadvantage, so recently the immediate loaded implant is getting popularity. Several literature has been published for clinical success of immediate loaded implant. The studies for the success rate of immediate loaded implant in multi-way has been reporting, nevertheless, we don't have yet a probable success. Various studies have been practiced that the advantages and disadvantages associated with immediate loaded implant, and factors that may influence the success of immediate implant, including patient selection, type of bone quality, required implant length, structure of the implant, surgical skill, need for achieving primary stability, control of occlusal force, peri-implant bone activity. The objective of this study is to review the literature related to immediate loading of implants and to discuss factors that may influence this treatment modality, based on scientific evidence.