Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force  

Lee, Yongwoo (Dept. of Mechanical & Automotive Engineering, Shinhan University)
Jang, Yong Hoon (School of Mechanical Engineering, Yonsei University)
Publication Information
Tribology and Lubricants / v.37, no.4, 2021 , pp. 136-143 More about this Journal
Abstract
This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.
Keywords
dental implant; abutment-implant connection; FEM; srew loosening; fastening force; cyclic load;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Seo, J., Chun, H., Han, C., "Analysis of loosening mechanism of different connection for dental implant", Proc. Fall Conf. KSME., Korea, December 2007
2 Kim, S., Jang, Y. H., "Critical Wedging Coefficient in Frictional Elastic System Considering Separation State", Tribol. Lubr., Vol.36, No.6, pp.324-331, 2020, https://doi.org/10.9725/kts.2020.36.6.324   DOI
3 Seo, J., Chun, H., Han, C., "Development of an analytical model for dental screw loosening", Proc. Fall Conf. KSME., Korea, November 2005
4 Chung, H., Yang, S., Park, J., Park, C., Shin, J., Yang, H., "Stress distribution of implants with external and internal connection design : a 3-D finite element analysis", J Dent Rehabil Appl Sci., Vol.33, No.3, pp.189-198, 2017   DOI
5 He, Y., Fok, A., Aparicio, C., Teng, W., "Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study", Clin Implant Dent Relat Res., Vol.21, No.4, pp.741-752, 2019, https://doi: 10.1111/cid.12792   DOI
6 Kitagawa, T., Tanimoto, Y., Odaki, M., Nemoto, K., Aida, M., "Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system", J Biomed Mater Res B Appl Biomater., Vol.75, No.2, pp.457-463, 2005.
7 Kanneganti, K. C., Vinnakota, D. N., Pottem, S. R., Pulagam, M., "Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study", J Indian Prosthodont Soc., Vol.18, No.2, pp.161-167, 2018.   DOI
8 Eskitascioglu, G., Usumez, A., Sevimay, M., Soykan, E., Unsal, E., "The influence of occlusal loading location on stresses transferred to implant-.supported prostheses and supporting bone: A three-.dimensional finite element study", J Prosthet Dent, Vol.91, No.2, pp.144-150, 2004, http://doi.org/10.1016/j.prosdent.2003.10.018   DOI
9 Seo, J., Chun, H., Han, C., "Study of an analytical model for screw loosening mechanism of dental implant", Proc. Spring Conf. KSME., Korea, May 2007.
10 Wittneben, J. G., Buser, D., Salvi, G. E., Burgin, W., Hicklin, S., Bragger, U., "Complication and failure rates with implant-supported fixed dental prostheses and single crowns: a 10-year retrospective study", Clin Implant Dent Relat Res., Vol.16, No.3, pp.356-364, 2014, https://doi:10.1111/cid.12066   DOI
11 Sanchez-Perez, A., Moya-Villaescusa, M. J., JornetGarcia, A., Gomez, S., "Etiology, risk factors and management of implant fractures", Med Oral Patol Oral Cir Bucal., Vol.15, No.3, pp.504-508, 2010.
12 Segundo, R. M., Oshima, H. M., Silva, I. N., et al., "Stress distribution of an internal connection implant prostheses set: a 3D finite element analysis", Stomatologija, Baltic Dental and Maxillofacial Journal, Vol.11, No.2, pp.55-59, 2009.
13 Fujita, R., Kanno, Y., "Enumeration of all wedged equilibrium configurations in contact problem with coulomb friction", Comput Methods Appl Mech Eng., Vol.199, pp.1202-1215, 2010, https://doi.org/10.1016/j.cma.2009.12.008   DOI
14 Barber, J. R., Contact Problems Involving Friction. In: Paggi M., Hills D. (eds) Modeling and Simulation of Tribological Problems in Technology. CISM International Centre for Mechanical Sciences (Courses and Lectures), Vol.593, pp.41-93, Springer, Cham, 2020 (ISBN: 978-3-030-20377-1), https://doi.org/10.1007/978-3-030-20377-1_2
15 Klarbring, A., Contact, Friction, Discrete Mechanical Structures and Mathematical Programming. In: Wriggers P., Panagiotopoulos P. (eds) New Developments in Contact Problems, Vol.384, pp.55-100, Springer, Vienna,1999 (ISBN: 978-3-7091-2496-3), https://doi.org/10.1007/978-3-7091-2496-3_2
16 Kim, S., Jang, Y. H., "Determination of critical wedging coefficient for full-contact frictional systems using positive spanning", International Journal of Mechanical Sciences, Vol.177, 105576, 2020, https://doi.org/10.1016/j.ijmecsci.2020.105576   DOI
17 Lemos, C., Verri, F., Bonfante, E., Santiago, J., Pellizzer, E., "Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis", J Dent., Vol.70, pp.14-22, 2018, https://doi.org/10.1016/j.jdent.2017.12.001   DOI
18 Mao, Z., Yi, D., Cao, G., "Influence of sizes of abutments and fixation screws on dental implant system: a non-linear finite element analysis", biomedical engineering/biomedizinische technik, Vol.62, No.4, pp.357-364, 2017.   DOI