• 제목/요약/키워드: Impedance Measurement

검색결과 872건 처리시간 0.028초

피부 활성점 측정을 위한 회로설계 및 측정방법연구 (A Study on the circuit design and measurement method for the measurement of active points on skin)

  • 김민수;조영창
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.713-718
    • /
    • 2020
  • 피부 활성점(경혈) 측정 방법은 편리성, 저비용 및 비 침습으로 측정하기 때문에 많은 생체정보를 얻기 위한 기술이다. 본 연구에서는 피부 아래에 활성점을 측정할 수 있는 장점이 있는 3전극 측정방법을 사용되었다. 임피던스측정방법은 측정실험 결과와 관련성이 있는 등가전기회로를 통해서 증명되었다. 활성점의 특성주파수는 주변 피부보다 15-30Hz 높고, 리액턴스는 35-77kΩ 더 작게 측정되었다. 이 기술은 비침습 측정 시스템을 이용해서 활성점과 주변피부의 리액턴스와 특성주파수를 정확하고 객관적으로 분석되었다.

Measurement of Nonlinear Time-variant Source Characteristics of Intake and Exhaust Systems in Fluid Machines

  • Jang Seung-Ho;Ih Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제24권3E호
    • /
    • pp.87-89
    • /
    • 2005
  • The acoustical sources of intake and exhaust systems in fluid machines are often characterized by the source impedance and strength using linear frequency-domain modeling. In the case of the sources which are nonlinear and time-variant, however, the source parameters were sometimes incorrectly obtained. In this paper, the source model and direct measurement technique are modified in order to evaluate the effect due to nonlinear and periodically time-varying source character as well as the linear property of the reflectivity of in-duct fluid machine source. With a priori known kinematical information of the source, the types of nonlinear time-variant terms can be presumed by a simple physical model, in which there is practically no restriction on the form of the model. The concept of source impedance can be extendable by introducing the linear frequency response function for each nonlinear or time-variant input. Extending the conventional method and adapting the reverse MISO technique, it is possible to develop a direct method that can deal with the nonlinear time-variant source parameters. The proposed direct method has a novel feature that there is no restriction on the probability or spectral natures of the excited sound pressure data. The present method is verified by the simulated measurements for simplified fluid machines. It is thought that the proposed method would be useful in predicting the insertion loss or the radiated sound level from intake or exhaust systems.

경계에서의 음향 임피던스 특성에 대한 연구 고찰 (Brief Note on Acoustic Impedance Characteristics at Flow Boundaries)

  • 서성현
    • 한국추진공학회지
    • /
    • 제21권6호
    • /
    • pp.103-109
    • /
    • 2017
  • 연소화염 열에너지와 결합된 음향에너지 증가는 연소 불안정성을 유발할 수 있다. 연소 안정성 예측을 위해서는 연소실 내부 유동 경계에서 음향특성을 파악해서 궁극적으로 음향에너지의 증가 여부를 파악하는 것이 필요하다. 본 논문에서는 연소기 헤드와 같은 유동 경계 형상에 대한 음향 특성을 연구한 기존의 주요 분석적 결과를 정리하여, Strouhal 수로 표현되는 경계면 음향 임피던스 특성을 알아보았다. 또한 이중 마이크로폰을 활용한 실험적 방법을 통해 경계 음향 임피던스 특성에 대한 이론적/해석적 결과를 검증하기 위한 기법을 조사 정리하였다.

전기임피던스 단층촬영법을 이용한 외란위치 계측오차 (Measurement errors of the EIT systems using a phantom and conductive yarns)

  • 박지수;구상모;김충현
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1430-1435
    • /
    • 2016
  • Electrical impedance tomography (EIT) has been applied to measure the location of external disturbance using a phantom and conductive yarns. According to the test results, the addition of carbon nanotube particles into the phantom does not show remarkable improvement in location errors. On the other hand combined fabric, conductive yarns with fabric, and non-woven fabric, were added to evaluate its performance as a fabric sensor. The combined fabric resulted in a decrease of 21.5% in the circumferential location error and a decrease of 50% in the radial location error, compared to those of the yarns. Additionally, it was revealed that the measurement error is almost linearly proportional to the conductivity of the phantom liquid and resistance of the conductive yarns. The combined fabric can be a promising material for fabric sensors in sports utilities and medical devices.

Damage detection of composite materials via IR thermography and electrical resistance measurement: A review

  • Park, Kundo;Lee, Junhyeong;Ryu, Seunghwa
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.563-583
    • /
    • 2021
  • Composite materials, composed of multiple constituent materials with dissimilar properties, are actively adopted in a wide range of industrial sectors due to their remarkable strength-to-weight and stiffness-to-weight ratio. Nevertheless, the failure mechanism of composite materials is highly complicated due to their sophisticated microstructure, making it much harder to predict their residual material lives in real life applications. A promising solution for this safety issue is structural damage detection. In the present paper, damage detection of composite material via electrical resistance-based technique and infrared thermography is reviewed. The operating principles of the two damage detection methodologies are introduced, and some research advances of each techniques are covered. The advancement of IR thermography-based non-destructive technique (NDT) including optical thermography, laser thermography and eddy current thermography will be reported, as well as the electrical impedance tomography (EIT) which is a technology increasingly drawing attentions in the field of electrical resistance-based damage detection. A brief comparison of the two methodologies based on each of their strengths and limitations is carried out, and a recent research update regarding the coupling of the two techniques for improved damage detection in composite materials will be discussed.

전도성 섬유 기반 심전도 전극의 성능 평가에 관한 연구 (A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric)

  • 강보규;유선국
    • 전자공학회논문지
    • /
    • 제50권2호
    • /
    • pp.210-220
    • /
    • 2013
  • 인구의 고령화 사회에 접어든 최근에는 스마트 의류와 접목된 다양한 형태의 착용형 유헬스 디바이스가 개발되어 일상생활과 가정에서의 생활에 양손을 자유로이 하여 불편함 없이 건강변수 측정이 가능하게 되었다. 하지만 착용형 유헬스 디바이스의 보급과 더불어 이를 응용한 디바이스에 대한 연구 및 개발만이 우선되고 있는 현재, 이에 대한 성능 평가의 중요성에 대한 인식은 미흡한 실정이다. 본 논문에서는 이러한 착용형 유헬스 디바이스와 스마트 의류에 접목하여 전극으로 사용될 수 있는 전도성 섬유를 이용한 전극을 구성하여 심전도(ECG) 신호 측정을 위해 일반적으로 사용되는 패치타입의 Ag-AgCl 전극과 임피던스(Impedance), 심전도(ECG) 신호의 상관관계 비교와 CMRR 측정을 통하여 착용형 유헬스 디바이스에의 사용 가능성을 밝히기 위해 시험을 통한 성능차이를 평가 하였다.

초음파 음향임피던스 변환기를 이용한 저압 저진공 측정기술 연구 (The Study of Pressure Vacuum Measurement Techniques Using Ultrasonic Acoustic Impedance Transducers)

  • 홍승수;신용현;조승현;안봉영;임종연;최인묵
    • 한국진공학회지
    • /
    • 제19권5호
    • /
    • pp.319-325
    • /
    • 2010
  • 초음파 변환기의 기체 음향임피던스 변화를 이용해서 압력진공 측정기술을 연구하였다. 상용화된 한 쌍의 500 kHz 공중 초음파 변환기(air-coupled ultrasonic transducer)를 진공용기에 넣고 초음파 진폭을 측정하였다. 그 결과 6.66 kPa에서 202.65 kPa (약 2기압)까지 4회 반복 측정값으로부터 계산된 표준편차는 0.0093에서부터 0.3325 사이에 있었으며, 표준편차를 압력으로 나누어서 백분율로 나타낸 값은 133.32 kPa에서 0.018%이었고 202.65 kPa에서는 0.164%이었다.

S-parameter의 변화를 유도하는 임피던스 변화 감지를 통한 전자회로의 결함검출회로 (The defect detection circuit of an electronic circuit through impedance change detection that induces a change in S-parameter)

  • 서동환;강태엽;유진호;민준기;박창근
    • 전기전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.689-696
    • /
    • 2021
  • 본 논문에서는 고장예측진단 및 건전성 관리 기법(Prognostics and Health Management, PHM)을 적용하기 위해 해당 시스템 혹은 회로 내부에서 결함특성을 감지하고 예측할 수 있는 회로 구조를 제안하였다. 기존 연구에서 회로 결함의 진행에 따라, S-parameter 크기 최소값의 주파수가 변화하는 것을 확인하였다. 이러한 특성을 기존에는 네트워크 분석기(Network Analyzer)를 활용하여 측정하였으나, 본 연구에서는 같은 결함검출기법을 활용하더라도 큰 계측장비 없이 결함의 진행상황 및 잔여 수명, 결함발생 여부를 확인할 수 있는 소형화된 회로를 설계하였다. 본 연구에서는 S-parameter의 변화를 야기하는 임피던스의 변화를 감지할 수 있도록 회로를 설계하였으며, Bond-wire의 온도반복에 따른 S-parameter 변화 측정결과를 제안하는 회로에 적용하였다. 이를 통해 해당 회로가 Bond-wire의 결함을 감지할 수 있다는 것을 성공적으로 검증하였다.

Review of the Usefulness of Inhibitors for Reducing the Corrosion of Iron in $H_2S$ Environments

  • Kim, Han-Sang;Yoon, Eun-Sub
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.21-26
    • /
    • 2009
  • The influence of $H_2S$ on the corrosion of iron and the corrosion prevention mechanism of an inhibitor was investigated with a differential capacitance measurement and a weight loss measurement method. The results show that $H_2S$ accelerates both the anodic iron dissolution and the cathodic hydrogen evolution in most cases. However, $H_2S$ acts as an inhibitor of the corrosion of iron under certain special conditions. An EIS method is proposed to explain the ability of inhibitors.

Small Loop Antenna for EMI Controlled and Monitoring

  • Khemchan, A.;Khamphakdi, P.;Urabe, Junichiro;Khan-ngern, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.470-473
    • /
    • 2004
  • This paper presents conducted emission noise measurement from electronic equipment in frequency range of 1 MHz up to 30 MHz by small loop antenna. Small loop antenna measurement method can measure common-mode (CM) and differential-mode (DM) component of the noise on a pair of power line at the same time. The CM and DM can be measured separately. The theory of this measurement method is introduced and analyzed. The measured results were compared with the conventional measurement by Line Impedance Stabilization Network (LISN) and result a good trend between those methods.

  • PDF