Browse > Article
http://dx.doi.org/10.5573/ieek.2013.50.2.210

A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric  

Kang, Bo Kyu (Graduate School of Biomedical Engineering, Yonsei University)
Yoo, Sun Kook (Department of Medical Engineering, College of Medicine, Yonsei University)
Publication Information
Journal of the Institute of Electronics and Information Engineers / v.50, no.2, 2013 , pp. 210-220 More about this Journal
Abstract
Recently, as we move toward a society with an increasingly aged population, wearable U-health devices in various shapes with smart wear have been developed in order to conveniently measure health variables without using hands in daily life or at home. However, the problem is that only supply of the wearable U-health devices is focused and its applicable devices are studied and developed, which has resulted in lack of awareness of importance of performance evaluation. In this study, two electrodes were fabricated using conductive fabric which can be used as electrode if attached to wearable U-health devices or smart wear in order to measure ECG signal. Two electrodes those were fabricated using conductive fabric were compared the correlation, impedance and CMRR with patch typed Ag-AgCl electrode-normally used for measurement of ECG signal, so that the study would find out if the fabricated electrode can be used with the wearable U-health devices by testing and evaluating performances.
Keywords
Conductive Fabric; Performance Evaluation; Impedance; Correlation; Electrode;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 A Searle and L Kirkup, "A direct comparison of wet, dry and insulting bioelectric recording electrodes," Physiol. Meas. 21, pp. 271-283, 2000.   DOI   ScienceOn
2 Lun-De Liao, I-Jan Wang, Sheng-Fu Chen, jyh-Yeong Chang and Chin Teng Lin, "Design, Fabrication and Experimental Validation of a Novel Dry-Contact Sensor for Measuring Electroencephalography Signals without Skin Preparation," Sensors, 11, pp. 5819-5834, 2011.   DOI
3 Junchae Kim, Sun Ha Jee and Sun Kook Yoo, "Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile," Journal of Sensor Science and Technology, Vol. 21, No. 2, pp. 135-143, 2012.   DOI   ScienceOn
4 Bo Kyu Kang, In Ho Hwang, Sun K. Yoo " A Study on Performance Evaluation for ECG Device Using Wearable u-Health Smart Cloth and Belt," Bio-Medical System Conference and Ohsong Bio-Forum(BIT), pp. 148-151, Feb 17-19, 2011.
5 이석희, 류근택, "유비쿼터스 헬스케어를 위한 무선 생체신호 감시 시스템 설계," 대한전자공학회 논문지, 제49권 IE편, 제2호, 82-88쪽, 2012.6   과학기술학회마을
6 장용원, 신승철, 전영주, 김승환, "전도성 섬유를 이용한 운동중 생체 신호 측정 및 분석," 대한 전자공학회 추계 학술대회 논문집ΙΙ, 800-803쪽, 2006.
7 이학성, "임피던스 관계 행렬을 이용한 고집적 센서 어레이의 임피던스 분석에 관한 연구," 대한 전자공학회, 48권, SC편, 제3호, 1-5쪽, 2011년 5월.   과학기술학회마을
8 Enzo Pasquale Scilingo, Angelo Gemignani, Rita Paradiso, Nicola Taccini, Brunello Ghelarducci and Danilo De Rossi, "Performance Evaluation of Sensing Fabrics for monitoring Physiological and Biomechanical Variables," IEEE Transaction on Information technology in Biomedicine, Vol. 9, no. 3, pp. 345-352, September 2005.   DOI   ScienceOn
9 Long Yan and Hoi-Jun Yoo, "A Low-Power Portable ECG Touch with Two Dry Metal Contact Electrodes," Journal of Semiconductor Technology and Science, Vol.10 No.4, pp. 300-308, 2010. 12.   DOI   ScienceOn
10 민철홍, 김태선, "심전도 신호의 리드III 파형을 이용한 바이오 인식." 전자공학회 논문지. 제 48권, 6 호, 43-50쪽, 2011년 11월.
11 Merja M. Puurtinen, Satu M. Komulainen, Pasi K. Kauppinen, Jaakko A. Malmivuo and Jari A. K. Hyttinen, "Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel," Proceeding of the 28th IEEE, EMBS Annual International Conference, pp. 6012-6015, New York City, USA, Aug 30-Sept 3, 2006
12 Fabrie Axisa, Pierre Michael Schmitt, Claudine Gehin, Georges Delhomme, Eric McAdams, and Andre Dittmar, "Flexible Technologies and Smart Clothing for Citizen Medicine, Home Healthcare, and Disease Prevention," IEEE Transaction on Information Technology in Biomedicine, Vol. 9, No. 3, September 2005.
13 Israel Zepeda-Carapia, Agustin Marquez- Espinoza and Carlos Alvarado-Serrano, "Measurement of Skin-Electrode Impedance for a 12-Lead Electrocardiogram," 2nd International Conference on Electrical and Electronics Engineering(ICEEE) and XI Conference on Electrical Engineering(CIE 2005), pp.193-195, Mexico City, Mexico, September 7-9, 2005.
14 Sun K. Yoo " Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier," International Journal of Control, Automation, and System, Vol. 5, no. 5, pp601-605, October 2007.
15 Yu Mike Chi, Tzyy-Ping Jung, and Gert Cauwenbrghs, "Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review," IEEE Reviews in Biomedical Engineering, Vol. 3, 2010.
16 Kang-Hwi Lee, Jeong-Whan Lee, Yong-Jae Lee, Kyeong-Seop Kim, Heui-Koung Yang, Kun-Su Shin, Myoung-Ho Lee, "Implementation of Wearable Heart Activity Monitoring System Having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiography(ECG)," Trnas. KIEE, Vol. 57, No. 6, pp. 1102-1108, Jun, 2008.   과학기술학회마을
17 Deokwon Ko, Chany Lee, Eun-Joong Lee, Sang-Hoon Lee and Ki-Young Jung, "A Dry and Flexible Electrode for continuous-EEG Mornitoring Using Silver Balls Based Polydimethylsiloxane(PDMS)," Biomed Eng Lett, Vol. 2, pp. 18-23, 2012.   DOI