• Title/Summary/Keyword: Immunoassay

Search Result 569, Processing Time 0.022 seconds

QUANTITATION OF BARBITURATES IN URINE BY GC/MS AND ITS COMPARISON TO FLUORESCENCE POLARIZATION IMMUNOASSAY

  • Choo, Hea-Young;Park, Jeongeun;Park, Myung-Ja
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • Barbiturates are commonly abused tranquilizer and a rapid method to determine these drugs in biological samples is needed. In this study, was screened barbiturates in urine specimens by the fluorescence polarization immunoassay method(FPIA) and the positive samples were confirmed and identified by the more definitive GC/MS method. Fifteen positive smples which have barbiturate values higher than 0.5 ng/ml were analyzed by the GC/MS method. Eight samples were identified as phenobarbital and five samples were identified as crotilbarbitone.

  • PDF

Microfluidic Immunoassay Platform Using Antibody-immobilized Glass Beads and Its Application for Detection of Escherichia coli O157:H7

  • Lee, Nae-Yoon;Yang, Yoon-sun;Kim, Youn-Sang;Park, Sung-su
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.479-483
    • /
    • 2006
  • We developed a microfluidic immunoassay platform for the detection of various analytes such as bacterial pathogen by packing antibody-immobilized glass beads in spatially-isolated microchambers on a microfluidic device. Primary amines of antibody were covalently conjugated to carboxyl-terminated glass beads previously treated with aminosilane followed by glutaraldehyde. Through this covalent binding, up to 905 $\mu$g immunoglobulin G (IgG) per gram of glass beads was immobilized. For application, glass beads attaching antibody specific to Escherichia coli O157:H7, a foodborne pathogen, were packed into a microfluidic device and used for the detection of the serotype. This prototype immunoassay device can be used for the simultaneous detection of multiple analytes by sequentially packing different-sized glass beads attaching different antibody in discrete microchambers on a single microfluidic device.

The Coordination of Pyridyl-N to Pentacyanoferrate for the Electrochemical Detecting Small Organic Molecules

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.595-599
    • /
    • 2013
  • The coordination of pyridyl-N to pentacyanoferrate for the detection of small organic antigens in solution is presented. The unique contribution of this paper is the direct conjugation of pyridyl-N in small organic antigens to pentacyanoferrate. Pentacyanoferrate is promising as an electrochemical label owing to its good electro-chemical properties, which can be utilized to generate an electrical signal in homogeneous electrochemical immunoassays. The facilely synthesized pyridyl-N to pentacyanoferrate was characterized by the electrochemical and spectroscopic methods. Hippuric acid (HA) has been detected competitively on the interaction of free HA and pentacyanoferrate-(4-aminomethylpyridine-hippuric acid) (Fe-HA) to its antibody, with the detection limit of 0.50 ${\mu}g\;mL^{-1}$. While pentacyanoferrate-based immunoassay is in its simplicity and infancy, the proposed immunoassay offers attractive opportunities for developing pyridyl-N-based the electrochemical detection of small organic antigens in the health care area.

Electrochemical Immunoassay based on the Dopamine-antigen Conjugate for Detecting Hippuric Acid (항원인 마뇨산에 결합된 도파민을 이용한 전기화학적 면역 분석법)

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.3
    • /
    • pp.172-178
    • /
    • 2014
  • In this work, we describe an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid (HA). Urinary HA, of molecular weight 180 DA, is one of the major metabolites and biological indicators in toluene-exposed humans. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care. We propose the electrochemical immunoassay based on the dopamine-antigen conjugate for detecting hippuric acid. Our electrochemical immunoassay system employs a conjugate of dopamine (DA) as an electrochemical active molecule and hippuric acid (HA) as an antigen. As an electrochemical aspect, dopamine (DA) containing two hydroxyl group can show excellent redox signal. Also, dopamine-tethered hippuric acid (DA-HA) shows the reversible redox signal in the immunoassay. The competition between HA and DA-HA generated electric signals proportional to HA concentration. The electrochemical immunoassay was performed with DA-HA on the screen printed carbon electrodes (SPCEs), and then applies the mixture antigen (HA) and HA-antibody. The electrical signals were proportional to HA in the range of 0.010~2.500 mg/mL which is enough range to be used for the point-of-care.

Analysis of Human Serum Amyloid A-1 Concentrations Using a Lateral Flow Immunoassay with CdSe/ZnS Quantum Dots (Human Serum Amyloid A-1 단백질 농도 분석을 위한 CdSe/ZnS 양자점 기반의 Lateral Flow Immunoassay 방법 개발)

  • Fajri, Aidil;Goh, Eunseo;Lee, Sanghyuk;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.429-434
    • /
    • 2019
  • A lateral flow immunoassay platform utilizing antibody functionalized water soluble CdSe/ZnS semiconductor quantum dots (QDs) was developed for the analysis of human serum amyloid A-1 (hSAA1) in a buffer solution. hSAA1 was chosen as a target protein because it is regarded as a potential biomarker associated with early diagnosis and prognosis in patients of lung cancer. The immunoassay strip on a nitrocellulose membrane was fabricated by spraying two lines composed of a test line with a monoclonal antibody against hSAA1 (10G1) (anti hSAA1) and a control line of anti-chicken IgY. While the CdSe/ZnS QDs synthesized in an organic phase were transferred to a water phase by ligand exchange using carboxylic acid modified alkane thiol. The QDs was then conjugated to monoclonal antibody against hSAA1 (14F8) [anti hSAA1 (14F8)] and used as a fluorescent detection probe. The sequential lateral flow of hSAA1 in different concentration and QDs-anti hSAA1 (14F8) complex allowed to form the surface sandwich complex of anti hSAA1 (10G1)/hSAA1/QD-anti hSAA1 (14F8), which was then analyzed using fluorescence microscope. A 100 nM concentration of hSAA1 protein can be detected by naked eyes under an optimized lateral flow buffer condition with a sensing time of 5 mins.

Polymerase Chain Reaction Detection of Mycobacterium tuberculosis and Fine Needle Aspiration Cytology for the Diagnosis of Tuberculous Lymphadenitis (결핵성 림프절염의 진단를 위한 세침흡인 세포검사 및 중합효소연쇄 반응과 효소면역법을 이용한 Mycobacterium tuberculosis의 검출)

  • Kim, Joo-Heon;Kim, Nam-Hoon;Kang, Dong-Wook;Park, Mee-Ja;Moon, Sang-Kyoung;Yu, Tae-Cho;Jang, Eun-Ju
    • The Korean Journal of Cytopathology
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 2001
  • Tuberculous lymphadenitis is not uncommon in Korea. Therefore, an inexpensive, safe and rapid method is needed to diagnose the tuberculous lymphadenitis. Flne needle aspiration cytology Is a good method for this purpose, but has several limitations in the diagnosis of tuberculous lymphadenitis, especially when the presence of acid-fast bacilli is not proved. To evaluation the usefulness of the polymerase chain reaction with enzyme immunoassay technique in the detection of Mycobacterium tuberculosis (M. tuberculosis) In the cervical Iymph node asplrates, the authors performed fine needle aspiration cytology and M. tuberculosis PCR with enzyme immunoassay for mycobacterial DNA sequences from 15 cases of the fine needle aspirates. Cytomorphologically, the cases were categorized into three types: predominantly necrotic materials; typical epithelioid cell granulomas with or without slant cells and caseous necrosis; and non-tuberculous lesions, such as reactive lymphadenitis, abscess, metastatic carcinoma and malignant lymphoma. M. tuberculosis DNA was found in 8 of 15 cases by PCR with enzyme immunoassay. Negative findings on PCR were achieved in 7 cases, which revealed non-tuberculous tymphadenopathy. In conclusion, we suggest that M. tuberculosis PCR with enzyme immunoassay using the fine needle aspirates is a very useful tool for the diagnosis of tuberculous lymphadenitis.

  • PDF

Detection of antibodies and antigens of Aujeszky's disease virus using dot-immunoassay (Dot-immunoassay를 이용한 Aujeszky's disease virus항원 및 항체 검출)

  • Jun, Moo-hyung;Cho, Young-sung;Chang, Kyung-soo
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.529-536
    • /
    • 1994
  • To establish more specific and simple diagnostic methods for detection of the antibodies and antigens of Aujeszky's disease virus(ADV), we designed indirect dot-immunoassay(IDI) and double sandwich dotimmunoassay(DSDI) using the solid phases of nitrocellolose paper and polystyrene plate. The diagnostic efficacy of these methods was investigated. As the sensitivity of IDI was tested by various virus concentration, the specimens with the virus titer above $10^{4.0}TCID_{50}/0.2ml$ showed positive reaction, but that below $10^{1.0}TCID_{50}/ml$ revealed negative. Tonsil emulsion at the virus titer of $10^{4.5}TCID_{50}/0.2ml$ showed the highest sensitivity as diluted by 1/100. In detection of ADV antigens from the various tissues of the rats and pigs infected with ADV, IDI using monoclonal antibody showed the higher specificity as compared with IDI using polyclonal antibody and virus isolation method. The efficacy of the DSDI for detection of ADV antibody was compared with other tests. The sensitivity of DSDI was higher than virus neutralization(VN) and agar gel immunodiffusion test(AGID). Meanwhile, specificity of DSDI was lower than AGID, but similar to IDEA. In comparison with VN test, DSDI showed 96.9% agreement to VN test that is the highest of three tests. In general, application of polyclonal antibody in both tests caused the higher sensitivity but the lower specificty.

  • PDF

Optimization of liquid phase enzyme immunoassay for determining of progesterone (Progesterone 측정을 위한 액상(液相) 효소면역측정법(酵素免疫測定法)의 최적조건에 관한 연구)

  • Kang, Chung-boo;Choi, Il-kwan;Son, Min-soo;Hur, Ju-hyeong;Kim, Chur-ho
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.429-434
    • /
    • 1992
  • This study was carried out to develop an effective liquid-phase double antibody enzyme immunoassay for determining of progesterone. The optimum conditions of assay system, 1st and 2nd antibodies, enzyme conjugate, and time reaction were invested. The bovine plasma progesterone level in dairy cattle and korean native bulls were also analyzed. The results obtained were as follows; 1. The reproducibility of petroleum ether was superior to that of ethyl ether as extract solvent of progesterone in plasma. 2. The optimum dilution rate of 1st and 2nd antibody was 30,000 and 10 times, respectively. Affer the reaction of enzyme conjugate to progesterone 1st antibody, and then 2nd antibody competition reaction was enough for over 1hr. 3. Average plasma progesterone level in 4 pregnant and 9 nonpregnant Holstein was $2.5{\pm}0.5$ and $0.7{\pm}0.2ng/m{\ell}$, respectively. Average plasma progesterone level of 10 Korean native bulls was $0.1{\pm}0.001ng/m{\ell}$ From these results, by using liquid phase double antibody enzyme immunoassay for progesterone is applicable to detect of early pregnancy diagnosis, factorial analysis of reproductive disorder, and also reproductive physiological function such as monitoring of cyclicity during the post-partum period.

  • PDF

Developments of Hormone Assays, Second Generation: Non-Isotopic Immunoassays (호르몬 측정법의 발달 제 2세대: 비방사면역측정법)

  • Lee, Chang-Joo;Kim, Sang Soo;Yoon, Yong-Dal
    • Development and Reproduction
    • /
    • v.9 no.2
    • /
    • pp.65-83
    • /
    • 2005
  • The three important phases in the development of ligand immunoassays are identified and summarized. The competitive radiolabelled hormone measurement had been developed in the first and early in the second generations(1950s to 1960s), such as radioimmunoassays(RIA) or immunoradiometric(saturation) assays(IRMA), and used in all most of the hormone and also analyte in biological samples. In the second generation, ultrasensitive non-isotopic immunoassays(NIA) were developed using monoclonal antibodies(McAb), labelling the McAb and high specific activity non-isotopic labels. After their usefulness, advantages and disadvantages has been evaluated and non-competitive methods are discussed. The chip/microarray based multianalyte ligand assays(microspot or genechip methods) are developed and known as alternative ones in the third generation. We summarize the developments of NIAs and its usefulness, and then introduce briefly the new ligand assays.

  • PDF