• Title/Summary/Keyword: Image Diagnosis

Search Result 1,412, Processing Time 0.025 seconds

Preparation of Gold Coated Liposomes for CT Contrast Medium (CT 조영을 위한 금 코팅 리포솜의 제조)

  • Wee, Tae In;Jeon, Ye Won;Cho, Young Jae;Cho, Sung Keun;Ha, Jeung;Lee, Jeong Won;Cho, Sun Hang;Han, Hee Dong;Shin, Byung Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.634-639
    • /
    • 2013
  • The use of medical imaging has been increased for diagnosis of cancer or vessel disease. Among the medical imaging, computed tomography (CT) is one of the popular methods, however, which should need administration of contrast medium. Therefore, we developed gold coated liposomes (GCL) as a contrast medium. To coat gold on the liposomal surface, positive charged liposomes was prepared and then negative $Au^-$ can coat on the liposomal surface by electronic interaction. The size of GCL was $154.8{\pm}9.2$ nm and surface charge was $27{\pm}3.2$ mV, respectively. The morphology of GCL was confirmed by electron microscopy (SEM) and transmission electron microscopy (TEM). The coating efficiency of gold was 18%. Chemical procedure for gold coating on liposomal surface was not toxic for cell cytotoxicity by MTT assay. Finally, we demonstrated attractive CT image for GCL. Taken together, the GCL would be useful for various vessel related disease as a contrast medium.

The Clinical Usefulness of Tc-99m ECD Brain SPECT in Acute Measles Encephalitis (홍역 후 발생된 급성 뇌염 진단시 Tc-99m ECD 뇌혈류 SPECT의 임상적 유용성)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.229-234
    • /
    • 2003
  • Purpose: Since the prognosis of measles encephalitis is poor, early diagnosis and proper management are very important to improve clinical outcomes. We compared Tc-99m ECD brain SPECT (SPECT) with MR imaging (MRI) for the detection of acute measles encephalitis. Materials and Methods: Eleven patients(M : F=4 : 7, age range 18 months-14 yrs) with acute measles encephalitis were enrolled in this studies. All of them underwent both MRI and SPECT. The results of SPECT were scored from 0 (normal) to 3 (most severe defect) according to perfusion state. We compared two image modalities for the detection of brain abnormality in acute measles encephalitis. Results: Seven of 11 patients (63.6%) revealed high signal intensity in the white matter on T2WI of MRI, on the other hand all patients (100%) showed hypoperfusion on SPECT. Severe perfusion deficits above score 2 were located with decreasing frequencies in the frontal lobe (81.8%), temporal lobe (72.7%), occipital lobe (27.3%), basal ganglia (27.3%), and parietal lobe (9.1%). Conclusion: We conclude that SPECT is more useful than MRI for the detection of brain involvement in patients with acute measles encephalitis.

Automated Functional Morphology Measurement Using Cardiac SPECT Images (SPECT 영상을 사용한 기능적 심근형태의 자동 계측법 개발)

  • Choi, Seok-Yoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • For the examination of nuclear medicine, myocardial scan is a good method to evaluate a hemodynamic importance of coronary heart disease. but, the automatized qualitative measurement is additionally necessary to improve the decoding efficiency. we suggests the creation of cardiac three-dimensional model and model of three-dimensional cardiac thickness as a new measurement. For the experiment, cardiac reduced cross section was obtained from SPECT. Next, the pre-process was performed and image segmentation was fulfilled by level set. for the modeling of left cardiac thickness, it was realized by applying difference equation of two-dimensional laplace equation. As the result of experiment, it was successful to measure internal wall and external wall and three-dimensional modeling was realized by coordinate. and, with laplace formula, it was successful to develop the thickness of cardiac wall. through the three-dimensional model, defects were observed easily and position of lesion was grasped rapidly by the revolution of model. The model which was developed as the support index of decoding will provide decoding information to doctor additionally and reduce the rate of false diagnosis as well as play a great role for diagnosing IHD early.

Comparative Evaluation of Images after Applying Quantum Denoising System Algorithm to Brain Computed Tomography (뇌 컴퓨터단층검사 시 양자잡음제거 알고리즘을 적용한 영상의 비교평가)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.589-594
    • /
    • 2017
  • The objective of this study was to evaluate the enhancement effects of the quantum denoising system (QDS) on brain CT images. This retrospective study was conducted with 45 adults who visited G Radiology located in Gyungbuk for having brain CT tests between Jul 2017 and Oct 2017 after receiving consents. Subjects were divided into a control group (A group; no QDS(-) application during the brain CT test) and a treatment group (B Group; QDS(+) application during the brain CT test). The following conclusions were obtained from the study. The noise values at the Pons part and the Vermis part were significantly (p<0.05) lower in B Group ($Pons=5.41{\pm}1.05HU$; $Vermis=5.28{\pm}0.73HU$) than A Group ($Pons=6.92{\pm}0.98HU$; Vermis=6.72). The SNR values at the Pons part and the Vermis part were significantly (p<0.05) higher in B Group ($Pons=7.28{\pm}2.56$; $Vermis=8.63{\pm}3.04$) than A Group ($Pons=5.21{\pm}1.28$; $Vermis=6.23{\pm}1.49$). In conclusion, the results of this study suggested that the application of QDS to the brain CT test would enhance the signal to noise ratio (SNR) and the contrast to noise ratio (CNR) to provide an image more appropriate for diagnosis.

Defining the Tumour and Gross Tumor Volume using PET/CT : Simulation using Moving Phantom (양전자단층촬영장치에서 호흡의 영향에 따른 종양의 변화 분석)

  • Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.935-942
    • /
    • 2021
  • Involuntary movement of internal organs by respiration is a factor that greatly affects the results of radiotherapy and diagnosis. In this study, a moving phantom was fabricated to simulate the movement of an organ or a tumor according to respiration, and 18F-FDG PET/CT scan images were acquired under various respiratory simulating conditions to analyze the movement range of the tumor movement by respiration, the level of artifacts according to the size of the tumor and the maximum standardized uptake value (SUVmax). Based on Windows CE 6.0 as the operating system, using electric actuator, electric actuator positioning driver, and programmable logic controller (PLC), the position and speed control module was operated normally at a moving distance of 0-5 cm and 10, 15, and 20 reciprocations. For sphere diameters of 10, 13, 17, 22, 28, and 37 mm at a delay time of 100 minutes, 80.4%, 99.5%, 107.9%, 113.1%, 128.0%, and 124.8%, respectively were measured. When the moving distance was the same, the difference according to the respiratory rate was insignificant. When the number of breaths is 20 and the moving distance is 1 cm, 2 cm, 3 cm, and 5 cm, as the moving distance increased at the sphere diameters of 10, 13, 17, 22, 28, and 37 mm, the ability to distinguish images from smaller spheres deteriorated. When the moving distance is 5 cm compared to the still image, the maximum values of the standard intake coefficient were 18.0%, 23.7%, 29.3%, 38.4%, 49.0%, and 67.4% for sphere diameters of 10, 13, 17, 22, 28, and 37 mm, respectively.

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

Functional and esthetic improvement through reconstruction of anterior guidance using the modified Dahl principle and copy-milled technique of CAD/CAM system: A case report (적절한 전방 유도 재현을 위해 수정된 Dahl 원리 및 CAD/CAM 복제 기법을 이용하여 전치부의 기능 및 심미성을 개선한 보철 수복 증례)

  • Kim, Sung-Ho;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.160-170
    • /
    • 2019
  • The anterior guidance is one of the important factors in prosthodontic treatment of anterior teeth. The lingual surface shape of anterior restorations is so critical that small errors of treatment procedure can cause discomfort of the patient and disharmony of the dentition. If the anterior restorations are achieved harmonious anterior guidance through the fabrication and adjustment of provisional restorations, it is important to accurately reproduce the lingual surface shape of provisional restorations as the final prosthesis. In this case report, it was used the modified Dahl principle and copy-milled technique of computer-aided design/computer-aided manufacturing (CAD/CAM) system for systematic diagnosis and treatment. Therefore, we tried to reconstruct the restoration shape more precisely by setting the appropriate anterior guidance and superimposing the digital image of the abutment teeth and the provisional restorations. Thus, by promoting functional and esthetic recovery, this case report demonstrates satisfying results to both the patients and dentist.

Comparisons of the Plastic Changes in the Central Nervous System in the Processing of Neuropathic Pain (신경병증성 통증의 처리 과정에 있어 중추신경계의 가소성 변화 비교)

  • Kwon, Minjee
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.39-48
    • /
    • 2021
  • According to International Associating for the Study of Pain (IASP) definition, neuropathic pain is a disorder characterized by dysfunction of the nervous system that, under normal conditions, mediates virulent information to the central nervous system (CNS). This pain can be divided into a disease with provable lesions in the peripheral or central nervous system and states with an incorporeal lesion of any nerves. Both conditions undergo long-term and chronic processes of change, which can eventually develop into chronic pain syndrome, that is, nervous system is inappropriately adapted and difficult to heal. However, the treatment of neuropathic pain itself is incurable from diagnosis to treatment process, and there is still a lack of notable solutions. Recently, several studies have observed the responses of CNS to harmful stimuli using image analysis technologies, such as functional magnetic resonance imaging (fMRI), positron emission tomography (PET), and optical imaging. These techniques have confirmed that the change in synaptic-plasticity was generated in brain regions which perceive and handle pain information. Furthermore, these techniques helped in understanding the interaction of learning mechanisms and chronic pain, including neuropathic pain. The study aims to describe recent findings that revealed the mechanisms of pathological pain and the structural and functional changes in the brain. Reflecting on the definition of chronic pain and inspecting the latest reports will help develop approaches to alleviate pain.

Creation of the dental virtual patients with dynamic occlusion and its application in esthetic dentistry (심미치의학 영역에서 동적 교합을 나타내는 가상 환자의 형성을 통한 전치부 보철 수복 증례)

  • An, Se-Jun;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.222-230
    • /
    • 2022
  • Digital technology is gradually expanding its field and has a great influence on various fields of dentistry. Recently in digital dentistry, the importance of superimposing various 3-dimensional (3D) image data is emerging, in order to utilize gathered data effectively for diagnosis and prosthesis fabrication. Integrating data from facial scans, intraoral scans, and mandibular movement recordings can create a virtual patient. A virtual patient is formed by integrating digital 3D diagnostic data such as intraoral and extraoral soft tissues, residual dentition, and dynamic occlusion, and the results of prosthetic treatment can be evaluated virtually. The patients in this case report were a 37-year-old female whose chief complaint is that the appearance of the existing prosthesis was distorted and a 55-year-old female patient whose anterior prosthesis needed to be refabricated after the endodontic treatment. 3D facial scans were obtained from each patient, and the patient's mandibular movements were recorded using ARCUS Digma 2 (KaVo Dental GmbH, Biberach an der Riss, Germany). The collected data were integrated on computer-aided design (CAD) software (Exocad dental CAD; exocad GmbH, Darmstadt, Germany) and transferred to a virtual articulator to create a digital virtual patient. The temporary fixed prostheses were designed, restored, and evaluated, and it was reflected into the final restorations. With the aid of the virtual dental patient, accuracy and predictability could be increased throughout treatment, simplifying the occlusal adjustment and clinical evaluation with improved esthetic outcomes.

A Study on Various Sizes and Volumes of the Palate among the Korean Population in Mixed Dentition (한국 인구집단에서 부정교합 환아의 구개의 크기 및 용적에 관한 연구)

  • Jimyung, Choi;Jisun, Shin;Miran, Han;Junhaeng, Lee;Jongsoo, Kim;Jongbin, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.329-339
    • /
    • 2022
  • The purpose of this study was to compare the palatal dimensions (volume, width, length, and height) in different malocclusions (Class I, II, and III) in mixed dentition using a three-dimensional digital scanner. The study was performed on 30 selected casts from 1400 casts that were taken at the Department of Pediatric Dentistry at Dankook University. Casts consisted of Class I, II, and III malocclusion groups in Hellman's dental age IIIA. The mean age was 8 years and 6 months ± 11 months. Each cast was scanned by three-dimensional digital scanner, Medit T710 (Medit, Seoul, Korea), and shaped into the three-dimensional image and calculated palatal dimensions using the Plan T program (SMD solution, Seoul, Korea). The values were statistically compared and evaluated by Kruskal-Wallis followed by the Mann-Whitney test. According to our results, subjects with Class II malocclusion showed lower palatal width and longer palatal length compared to those with Class I and Class III. For palatal height, Class III malocclusion subjects in mixed dentition exhibited a larger number than Class II and Class I. Lastly, for palatal volume, compared to other malocclusions, Class III showed higher results; however, there were no significant differences. The form of the palate differs in types of malocclusions and understanding of these differences is important in clinical significance. Based on this study, the understanding of the relationship between the shape of the palate and the skeletal pattern provides useful information about orthodontic treatment plans, early diagnosis of malocclusion, and morphological integration mechanisms. Orthopedic treatment in the maxilla should be performed during early and intermediate mixed dentition to enhance treatment efficiency.