• Title/Summary/Keyword: IEC 61400

Search Result 87, Processing Time 0.032 seconds

Analysis on Turbulence Intensity Characteristics at Gimnyeong, Jejudo by Applying IEC 61400 Wind Turbine Standards (IEC 61400 풍력표준을 적용한 제주도 김녕 난류강도 특성분석)

  • Kim, Hyun-Goo;Jeong, Tae-Yoon;Jang, Moon-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.59-65
    • /
    • 2010
  • Analysis on turbulence intensity profile depending on wind speed is an important process to set up design condition of wind turbine in terms of fatigue load. This paper tests goodness of fit of turbulence intensity empirical equations suggested by the IEC 61400 Standards with Jejudo Gimnyeong met-tower measurement, which is erected at a seashore. Therefore sea breeze and land breeze coexist. Sea breeze case showed apparent increasing trend of turbulence intensity in a high wind speed regime due to increase of sea surface roughness. However, neither inland wind turbine standard IEC 61400-1 nor offshore wind turbine standard IEC 61400-3 fit such a trend adequately. On the other hand, the modified empirical equation of turbulence intensity of IEC 61400-3 derived from Germany FINO1 application study by considering turbulence intensity behavior in a high wind speed regime showed good agreement with the measurement. Therefore, we can reconfirm and conclude that IEC 61400-3 Ed.1 legislated in 2009 needs to be modified.

LVRT Control Strategy of Generic Wind Turbine Simulation Model based on IEC 61400-27 (IEC 61400-27에 기반한 가변속 풍력터빈 시뮬레이션 모델의 LVRT 제어전략)

  • Kim, Soo-Bin;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.123-124
    • /
    • 2015
  • 국제 전기기술 위원회(International Electro-technical Commission; IEC)에서는 풍력발전 시스템의 표준화된 전력 안정도 연구에 적합한 전기적 시뮬레이션 모델에 대한 규정 IEC 61400-27을 제정 중에 있다. 본 논문에서는 IEC 61400-27에서 제시하고 있는 풍력터빈의 시뮬레이션 모델을 구현하였으며, 이를 통해 규정에서 제시하고 있는 풍력터빈 시뮬레이션 모델의 저전압 사고시 LVRT 제어전략에 따른 특성을 파형을 통해 나타내었다

  • PDF

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.

Wind Generation Monitoring System based on International Standard IEC61400-25 (IEC61400-25 국제표준프로토콜을 적용한 풍력 발전 모니터링 시스템 개발 사례 연구)

  • Choi, Young-Jun;Lee, Seung-Jae;Choi, Myeon-Song;Lee, Duck-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.16-18
    • /
    • 2010
  • This paper presents monitoring system based on IEC61400-25 for 750kW-class DFIG wind power generation system. It consists of wind turbine PLC, Local and Remote I/O Server, human machine interface, and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test IEC61400-25 communication capability of monitoring system and evaluate the performance of 750kW-class WTS.

Implementation of IEC 61400-25 based communication system for wind power plants (풍력발전 설비용 IEC 61400-25 기반 통신 시스템 구축)

  • Lee, Jung-Hoon;Kim, Tae-O;Lee, Hong-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1356-1362
    • /
    • 2009
  • IEC 61400-25(Communications for monitoring and control of wind power plants) is established as a international standard by IEC TC 88 in 2007 with the growth of the wind power industry. In this paper, MMS service which is defined in lEC 61400-25 part 4 is implemented, and the wind power generator is objectified by using the VMD of MMS service. We also implemented MMS communication system between the wind power generator and the local control center using the proposed VMD. The performance of the developed MMS communication system is verified through the XML based user interface on the web browser.

An Study on Implementation of the Web interface based on IEC 61400-25 using XML for Remote Supervisory Control at Wind Power Plants (풍력 발전의 원격 감시 제어를 위한 IEC 61400-25 기반의 XML을 사용한 웹 인터페이스 구현에 관한 연구)

  • Seo, Min-Jae;Lee, Jung-Hoon;Kim, Gwan-Su;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.332-334
    • /
    • 2008
  • 최근 IEC는 변전소 자동화 시스템의 국제표준인 IEC 61850을 기반으로 하는 풍력 발전단지의 원격 감시 제어를 위한 통신시스템 표준인 IEC 61400-25를 발표하였다. 본 논문에서는 가상의 풍력 발전 통신 시스템을 SISCO 사의 "MMS-EASE Lite" 개발 도구를 사용하여 풍력 발전의 원격 감시 제어를 위한 서버와 클라이언트 간의 MMS 통신 서비스를 구현한다. 또한 IEC 61400-25 기반의 웹 인터페이스 구현을 위하여 뛰어난 확장성을 가진 XML(Extensible Markup Language, 확장성 생성 언어) 언어를 사용하여 풍력 발전단지의 논리 노드(Logical Node)를 구성하고, 원격 감시를 위한 웹 인터페이스를 구현하는 방법을 제안하고 실제 인터넷 환경에서 검증한다.

  • PDF

A Database Design Method for Wind Power Plant SCADA System based on IEC61400-25 (IEC61400-25 국제표준기반 풍력 SCADA시스템을 위한 데이터베이스 설계방안)

  • Chae, Chang Hun;Choi, Hyo Yul;Choi, Jun Suk
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.151-160
    • /
    • 2012
  • In this paper, a database method for Wind Power Plant SCADA system based on IEC61400-25 was designed. To manage big data, which is produced by the introduction of international standards and large/grouping of wind power plant, database should be systematically designed. As identify the characteristics of the wind power data and reflect the requirements of a user, it would be decreasing the waste of data space and managing efficiently the system. As a result, it is expected to reduce cost and effort in development and maintenance of Wind Power Plant.

Wind Generation Monitoring System Based on IEC61400-25 International Standard (IEC61400-25 국제 표준 프로토콜을 적용한 풍력 발전 모니터링 시스템 개발 사례)

  • Lee, Duck-Su;Lee, Jun-Chul;Hong, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.227-228
    • /
    • 2008
  • This paper presents monitoring system based on IEC61400-25 for 750kW-class DFIG wind power generation system. It is consists of wind turbine PLC, Local and Remote I/O Server, human machine interface, and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test IEC61400-25 communication capability of monitoring system and evaluate the performance of 750kW-class WTS.

  • PDF

EC 61400-25 Protocol based Monitoring and Control Protocol for Tidal Current Power Plant (IEC 61400-25 Protocol을 기반으로 하는 조류발전의 감시제어를 위한 통신시스템)

  • Kim, Jung-Woo;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.395-396
    • /
    • 2010
  • 조류발전단지는 넓은 지역에 산재하여 있고, 특성상 접근이 어렵기 때문에 원격으로의 감시제어가 필수적이다. 본 논문에서는 풍력발전의 감시제어를 위한 국제 표준 통신 프로토콜인IEC 61400-25을 기반으로 하는 조류발전의 감시제어를 위한 프로토콜을 제안한다. 이를 위해 조류발전기를 정보 모델로 모델링하고 IEC 61400-25를 기반으로 하는 통신 프로토콜을 적용 하였다. 또한 조류발전시스템과 제어센터와의 MMS 서비스를 이용한 통신시스템을 구현하였다.

  • PDF

Simplified Load Calculation and Structural Test for Scale Down Model of Small Wind Turbine Blade according to IEC 61400-2 (IEC 61400-2에 의거한 소형 풍력발전용 블레이드 축소모델의 단순 하중 계산 및 구조 시험)

  • Jang, Yun-Jung;Kang, Ki-Weon
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2013
  • This study deals with simplified load calculation and structural testing for scale down model of small wind turbine blade. First, the blade was designed and produced scale down to 0.2 ratio of initial blade. And moments were acquired by simplified load calculation equations according to IEC 61400-2 standard. Also, structural test using weight was conducted to obtain the maximum moment. Therefore maximum moments were compared at calculation and test.