• Title/Summary/Keyword: ICP analysis

Search Result 823, Processing Time 0.036 seconds

Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead (골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교)

  • Yoon, Chungsik;Choi, Inja;Park, Sungkyun;Kim, Rokho
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • This study was conducted to evaluate two sample digestion procedures and instrumental determination parameters for analysis of lead in bone. Amputated human legs were treated by acid digestion or microwave dissolution prior to spectrometric analysis. Inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GF-AAS) were used for determining bone lead levels. Recovery efficiencies using standard reference material from acid digestion measured by ICP-MS were in good agreement with those of the certified value, but in cases of acid digestion by GF-AAS and microwave digestion by both two methods, recovery underestimated and overestimated, respectively. For the bone samples, the lead concentrations obtained by ICP-MS after acid digestionwere in good agreement with those by GF-AAS (correlation coefficient = 0.983), but GF-AAS gave systematically higher values than ICP-MS. While a good agreement between two analytical methods after microwave digestion was also obtained (correlation coefficient = 0.950), bone lead concentrations from microwave were relatively higher than those from acid digestion. In conclusion, the use of the simple nitric acid digestion procedure at an ambient temperature coupled to ICP-MS seems to be efficient for the determination of lead in bone in consideration for both the convenience and validity.

Analysis of Copper, Zinc in Serum Using ICP-MS & AAS (ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구)

  • Lee, Yea-Jin;Kim, Dong-Yub;Lee, Go-Eun;Jo, Young-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

A study on the pretreatment of egg and dried pork for determination of selenium using ICP/MS (ICP/MS를 이용한 계란 및 건조돼지고기 중 셀렌 분석을 위한 전처리 방법 연구)

  • Park, Kyung-Su;Kim, Sun-Tae
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.465-470
    • /
    • 2001
  • A pretreatment procedure was performed to improve recovery of selenium from enriched egg and dried pork. Samples were digested with only $HNO_3$ in beaker at $150^{\circ}C$ for 3 hrs, and Se was determined by ICP-MS. Recovery of selenium was 94.2%, and its C.V. value was 2.48%. The analytical results of Se by this method were 0.13 - 2.71 mg/kg for egg and 0.36 - 4.19 mg/kg for dried pork.

  • PDF

Current Status of Intracranial Pressure Monitoring in Patients with Severe Traumatic Brain Injury in Korea : A Post Hoc Analysis of Korea Neurotrauma Databank Project with a Nationwide Survey

  • Youngheon Lee;Jung Hwan Lee;Hyuk Jin Choi;Byung Chul Kim;Seunghan Yu;Mahnjeong Ha;The KNTDB Investigators
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.5
    • /
    • pp.543-551
    • /
    • 2023
  • Objective : This study aimed to investigate the current status of intracranial pressure (ICP) monitoring in patients with severe traumatic brain injury (sTBI) in Korea and the association between ICP monitoring and prognosis. In addition, a survey was administered to Korean neurosurgeons to investigate the perception of ICP monitoring in patients with sTBI. Methods : This study used data from the second Korea Neurotrauma Databank. Among the enrolled patients with sTBI, the following available clinical data were analyzed in 912 patients : Glasgow coma scale score on admission, ICP monitoring, mortality, and extended Glasgow outcome scale score at 6 months. In addition, we administered a survey, entitled "current status and perception of ICP monitoring in Korean patients with sTBI" to 399 neurosurgeons who were interested in traumatic brain injury. Results : Among the 912 patients, 79 patients (8.7%) underwent ICP monitoring. The mortality and favorable outcome were compared between the groups with and without ICP monitoring, and no statistically significant results were found. Regarding the survey, there were 61 respondents. Among them, 70.4% of neurosurgeons responded negatively to performing ICP monitoring after craniectomy/craniotomy, while 96.7% of neurosurgeons responded negatively to performing ICP monitoring when craniectomy/craniotomy was not conducted. The reasons why ICP monitoring was not performed were investigated, and most respondents answered that there were no actual guidelines or experiences with post-operative ICP monitoring for craniectomy/craniotomy. However, in cases wherein craniectomy/craniotomy was not performed, most respondents answered that ICP monitoring was not helpful, as other signs were comparatively more important. Conclusion : The proportion of performing ICP monitoring in patients with sTBI was low in Korea. The outcome and mortality were compared between the patient groups with and without ICP monitoring, and no statistically significant differences were noted in prognosis between these groups. Further, the survey showed that ICP monitoring in patients with sTBI was somewhat negatively recognized in Korea.

Determination of Total Arsenic in Drinking Water by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라스마 질량 분석법(ICP-MS)을 이용한 음용수 중의 전체 비소의 정량)

  • Lim, Yoo-Ree;Park, Kyung-Su;Yoon, Yang-Hee;Kim, Sun-Tae;Chung, Jin-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.423-427
    • /
    • 2000
  • Total arsenic in drinking water such as spring, small water-supply system and mineral water was determined by inductively coupled plasma mass spectrometry. The contents of total arsenic were analyzed after acidification by nitric acid to become 1% in water samples. According to the results, total concentration of arsenic in drinking water was below 30ppb.

  • PDF

Cloning and Expression of Bacillus thuringiensis crylAa1 Type Gene. (Bacillus thuringiensis crylAa1 Type Gene의 클로닝과 발현)

  • 이형환;황성희;권혁한;안준호;김혜연;안성규;박수일
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.2
    • /
    • pp.110-116
    • /
    • 2004
  • The over-expression in E. coli of the pHLN1-SO(+) and pHLN2-80(-) plasmids cloned an insecticidal crystal protein (ICP) gene (crylAal type) from Bacillus thuringiensis var. kurstaki HD 1 was investigated through in part, the deletion of -80 bp promoter and an alternative change of cloning vector system. Two recombinant plasmids were constructed in an attempt to analyze the over-expression of the ICP in relations to its gene structure possessing only -14 bp [Shine-Dalgarno (SD) sequence of -80 bp promoter]. Also, anther two recombinant plasmids similarly cloned the icp gene in a different vector system. The amounts of ICP produced from the recombinants were measured by SDS-PAGE and confirmed by Western blot analysis. One clone, pHLRBS1-14 clone in which only the SD sequence in the inverted orientation icp gene appeared, was more evident than the pHLRBS2-14 clone in which only the -14 bp SD sequence of the right orientated icp gene was shown to exist. The pHLN2-80(-) clone produced more ICP proteins than the pHLRBS1-14 clone. In the two clones, pHLNUC1-80 right-oriented icp gene and the pHLNUC2-80 clone inverted-orientation icp gene in a new different vector, the pHLNUC2-80 produced more ICP proteins in E. coli system. These results indicate that the P/ac promoter, the inverted icp gene insertion and -80 bp promoter (-66 bp part of the icp gene promoters), were concerned with the expression of the icp gene in the recombinant plasmids. In addition, the expression mechanism might result from the disruption of the transcription-suppressing regions in the promoter regions.

Postoperative Speech Outcomes and Complications in Submucous Cleft Palate Patients

  • Park, Tae Seo;Bae, Yong Chan;Nam, Su Bong;Kang, Kyung Dong;Sung, Ji Yoon
    • Archives of Plastic Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-257
    • /
    • 2016
  • Background The postoperative speech outcomes of submucous cleft palate (SMCP) surgery are known to be poorer than those of other types of cleft palate. We attempted to objectively characterize the postoperative complications and speech outcomes of the surgical treatment of SMCP through a comparison with the outcomes of incomplete cleft palate (ICP). Methods This study included 53 SMCP patients and 285 ICP patients who underwent surgical repair from 1998 to 2015. The average age of the patients at the time of surgery was $3.9{\pm}1.9years$ for the SMCP patients and $1.3{\pm}0.9years$ for the ICP patients. A retrospective analysis was performed of the complications, the frequency of subsequent surgical correction for velopharyngeal dysfunction (VPD), and speech outcomes. Results In both the SMCP and ICP patients, no cases of respiratory difficulty, bleeding, or wound disruption were noted. Delayed wound healing and fistula occurred in 18.9% and 5.7% of the SMCP patients and in 14% and 3.2% of the ICP patients, respectively. However, no statistically significant difference in either delayed wound healing or fistula occurrence was observed between the two groups. The rate of surgical correction for VPD in the SMCP group was higher than in the ICP group. In the subset of 26 SMCP patients and 62 ICP patients who underwent speech evaluation, the median speech score value was 58.8 in the SMCP group and 66 in the ICP group, which was a statistically significant difference. Conclusions SMCP and ICP were found to have similar complication rates, but SMCP had significantly worse speech outcomes.

Characteristics of NbN Films Deposited on AISI 304 Using Inductively Coupled Plasma Assisted DC Magnetron Sputtering Method

  • Jun, Shinhee;Kim, Junho;Kim, Sunkwang;You, Yong Zoo;Cha, Byungchul
    • Journal of Surface Science and Engineering
    • /
    • v.46 no.5
    • /
    • pp.187-191
    • /
    • 2013
  • Niobium nitride (NbN) films were deposited on AISI 304 stainless steels by inductively coupled plasma (ICP) assisted dc magnetron sputtering method at different ICP powers, and the effects of ICP power on the phase formation, mechanical and chemical properties of the films were investigated. X-ray diffraction analysis (XRD) and field emission scanning electron microscopy (FESEM) were used to analyze the crystal structure and micro-knoop hardness was used to measure the hardness of the films. Also, 3-D mechanical profiler and a ball-on-disk wear tester were used to measure the thickness of the films and to estimate wear characteristics, respectively. The thickness of the films decreased but their hardness increased with increasing ICP power, and it was confirmed that only cubic ${\delta}$-NbN(200) remained at high ICP power. At lower ICP powers, a mixture of the hexagonal ${\delta}^{\prime}$-NbN and cubic ${\delta}$-NbN phases was obtained in the films and the hardness decreased. The corrosion potential value increased gradually with increasing ICP power, but the changes of ICP power did not significantly influence the overall corrosion resistance.

Analysis of heavy metal in polymer materials by combustion ICP-AES Method (연소법 전처리에 의한 고분자 물질 중 중금속의 분석)

  • Lim, Heon-Sung;Lee, Bo-Reum;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.615-618
    • /
    • 2010
  • An oxygen bomb combustion procedure were studied for determination of heavy metal in polymer materials such as polyvinyl chloride and polypropylene by ICP-AES. This method is proposed as a rapid and simple sample preparation for decomposition of polymer containing certified contents of the analytes by teflon coated oxygen bomb combustion using different absorbing solution. The recoveries of metal were found to be 30~102% from absorbed solution by ICP-AES method using polypropylene certified reference material(PP CRM-As, Ba, Cd, Hg, Pb, Zn). The recoveries of metal using PVC CRM(Cd, Hg, Pb) was found to be 45 ~101% with same procedures.

Analysis of the Concentration of Metal Elements in Freshwater Fish Otolith Using LA-ICP/MS (LA-ICP/MS를 이용한 담수 어류 이석 내 금속 원소 농도 분석)

  • Park, Hyun Woo;Yoon, Suk-Hee;Park, Jaeseon;Lim, Bo-Ra;Lee, Hyeri;Choi, Jong Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.4
    • /
    • pp.324-332
    • /
    • 2019
  • In this study, the possibility of a follow-up study on environmental pollution in domestic freshwater was identified by analyzing fish otoliths using Laser ablation-inductively coupled mass spectrometry (LA-ICP/MS). Fish otolith are known to be affected by the environment in which fish live. As a result, research on this subject is active in many countries; however, this is not the case in Korea. Therefore, in this study, the possibility of tracing environmental pollution using fish otoliths was identified by analyzing the components of metal elements used as indicators for environmental pollution. For the component analysis of metallic elements LA-ICP/MS, which can shorten analysis time by reducing the pretreatment process, was used. Sampling was conducted by dividing the research and the background area and carp, a freshwater species, was selected as the experimental fish species subject. Based on the established LA-ICP/MS conditions, the concentration of the metallic elements in the fish otoliths collected in the research area was 2202.9 mg kg-1, 2.03 times higher than the 1,086.3 mg kg-1 in the background area. All elements except for Li and U, were found to be higher in the research area than in the background area. Compared with the sediment measuring net analysis data, the distribution tendency of Zn, Pb, and Cu in sediment metal element concentrations in the two regions and distribution of metal element concentration in fish otoliths were similarly shown. These results confirm that fish otoliths can be used to track environmental pollutants, such as in sediments.