• 제목/요약/키워드: Hybrid power source

검색결과 273건 처리시간 0.022초

Recent Progress in Passive Radiative Cooling for Sustainable Energy Source

  • Park, Choyeon;Park, Chanil;Choi, Jae-Hak;Yoo, Youngjae
    • Elastomers and Composites
    • /
    • 제57권2호
    • /
    • pp.62-72
    • /
    • 2022
  • Passive daytime radiative cooling (PDRC) is attracting increasing attention as an eco-friendly technology that can save cooling energy by not requiring an external power supply. An ideal PDRC structure should improve solar reflectance and emissivity within the atmospheric spectral window. Early designs of photonic crystal materials demonstrated the benefits of PDRC. Since then, functional arrangements of polymer-based radiative cooling materials have played an important role and are rapidly expanding. This review summarizes the known inorganic, organic, and hybrid materials for PDRC. The review also provides a complete understanding of PDRC and highlights its practical applications.

A New Control Model for a 3 PWM Converter with Digital Current Controller considering Delay and SVPWM Effects

  • Min, Dong-Ki;Ahn, Sung-Chan;Hyun, Dong-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.346-351
    • /
    • 1998
  • In design of a digital current controller for a 3-phase (3 ) voltage-source (VS) PWM converter, its conventional model, i.e., stationary or synchronous reference frame model, is used in obtaining its discretized version. It introduces, however, inherent errors since the following practical problems are not taken into consideration: the characteristics of the space vector-based pulse-width modulation (SVPWM) and the time delays in the process of sampling and computation. In this paper, the new hybrid reference frame model of the 3 VS PWM converter is proposed considering these problems. In addition, the direct digital current controller based on this model is designed without any prediction or extrapolation algorithm to compensate the time delay. So the control algorithm is made very simple. It represents no steady-state error in input current control and has the optimized transient responses. The validity of the proposed algorithm is proved by the computer simulation and experimental results.

  • PDF

하이브리드 내연발전에서 도서 운영 결손액을 고려한 분산전원 최적 용량 산정 알고리즘 (Algorithm Calculating Optimal DG Capacity Considering Operating Deficit in Hybrid Internal Combustion Generation)

  • 손준호;김미영
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.655-660
    • /
    • 2018
  • 지리적 특성상, 도서지역에 전력을 공급하기 위해서 ICG(Internal combustion generation)가 사용되고 있으며, 이로 인하여 상당한 운영비, 염해문제 및 환경오염이 발생하고 있다. 이러한 도서지역에 대해서, KEPCO는 매년 상당한 운영결손액을 감당하고 있는데, 특히 연료비 및 지급수수료가 운영결손액의 상당 부분을 차지하고 있다. 특히, 지급수수료를 줄이기 위하여 근거리 도서 사이의 해저케이블을 통한 ICG 통합운영(integrated ICG, IICG)이 고려되고 있다. 한편, 저탄소 사회에 대한 수요 때문에 도서지역에 분산형전원(Distributed Generation, DG)이 도입되고 있다. 이러한 상황에서, 환경적 특성으로 인해 DG 출력이 불충분한 경우 보조 동력원으로 IICG가 사용되는, 즉, IICG에 DG를 도입한 하이브리드 내연발전(hybrid internal combustion generation, HICG)이 도입되고 있다. 따라서, 본 논문에서는 HICG에서 한전 운영결손액에 상응하게 도입될 수 있는 최적 DG 용량을 산정하는 알고리즘을 제안하였다. 시뮬레이션 결과, 연료비와 최대부하 크기는 최적 DG 용량에 큰 영향을 미치며, 최대부하가 서로 다른 여러 도서에 제안된 알고리즘을 적용하여 그 유효성을 확인하였다.

100% 신재생에너지 자원 기반 에너지 공급을 위한 태양광, 풍력 및 바이오 발전의 통합 전략 및 경제성 평가 (Economic Benefits of Integration of Supplementary Biopower and Energy Storage Systems in a Solar-Wind Hybrid System)

  • 황해진;문준영;김지용
    • Korean Chemical Engineering Research
    • /
    • 제58권3호
    • /
    • pp.381-389
    • /
    • 2020
  • 본 연구에서는 다양한 신재생 에너지원 기반 전력 공급 시스템 구축하고, 각 시스템의 최적 전력 공급 비용을 비교 분석 하였다. 특히, 풍력 및 태양광 등 대표적인 신재생에너지 생산 기술과 더불어 대형 에너지 저장 시스템 및 바이오매스 기반 전력 생산 기술을 포함함으로써, 신재생에너지 자원의 간헐성 및 에너지 공급과 수요의 불균형의 한계를 극복하였다. 본 연구에서 제안한 6가지의 신재생 에너지원 기반 전력 공급 시스템을 실제 제주도 전력 공급 문제에 적용함으로써, 제주도 지역의 최적 에너지 시스템을 규명하였으며, 다양한 에너지 생산 기술의 조합의 효과를 분석하였다. 분석 결과, 태양광 및 풍력 기반 전력 공급 단가는 각각 0.18, 0.28 $/kWh로 개별 자원 기반의 에너지 생산 시스템의 기존 전력망을 통한 공급 단가에 비해 경쟁력이 낮았다. 또한 자원의 간헐성 및 공급과 수요의 불균형 등 단일자원 기반의 단점을 효과적으로 개선하기 위하여 3가지 신재생 자원 및 대형 에너지 저장 시스템을 포함한 하이브리드 공급 시스템의 경제적 효과를 분석하였다. 그 결과 기존 전통적 전력망 공급과 가격 경쟁력을 갖는 0.08 $/kWh 수준의 100% 신재생에너지 기반 전력 공급 시스템 구축이 가능함을 규명하였다.

Drive Circuit of 4-Level Inverter for 42V Power System

  • Park, Yong-Won;Sul, Seung-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.112-118
    • /
    • 2001
  • In the near future, the voltage of power system for passenger vehicle will be changed to 42V from existing 14V./ Because of increasing power and voltage ratings used in the vehicle the motor drive system has high switching dv/dt and it generates electromagnetic interference (EMI) To solve these problems multi-level inverter system may be used The feature of multi-level inverter is the output voltage to be synthesized from several levels of voltage Because of this feature high switching dv/dt and EMI can be reduced in the multi-level inverter system But as the number of level is increased manufacturing cost is getting expensive and system size is getting large. Because of these disadvantages the application of multi-level inverter has been restricted only to high power drives. The method to reduce manufacturing cost and system size is to integrate circuit of multi-level inverter into a few chips But isolated power supply and signal isolation circuit using transformer or opto-coupler for drive circuit are obstacles to implement the integrated circuit (IC) In this paper a drive circuit of 4-level inverter suitable for integration to hybrid or one chip is proposed In the proposed drive circuit DC link voltage is used directly as the power source of each gate drive circuit NPN transistors and PNP transistors are used to isolate to transfer the control signals. So the proposed drive circuit needs no transformers and opto-couplers for electrical isolation of drive circuit and is constructed only using components to be implemented on a silicon wafer With th e proposed drive circuit 4- level inverter system will be possible to be implemented through integrated circuit technology Using the proposed drive circuit 4- level inverter system is constructed and the validity and characteristics of the proposed drive circuit are proved through the experiments.

Chance-constrained Scheduling of Variable Generation and Energy Storage in a Multi-Timescale Framework

  • Tan, Wen-Shan;Abdullah, Md Pauzi;Shaaban, Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1709-1718
    • /
    • 2017
  • This paper presents a hybrid stochastic deterministic multi-timescale scheduling (SDMS) approach for generation scheduling of a power grid. SDMS considers flexible resource options including conventional generation flexibility in a chance-constrained day-ahead scheduling optimization (DASO). The prime objective of the DASO is the minimization of the daily production cost in power systems with high penetration scenarios of variable generation. Furthermore, energy storage is scheduled in an hourly-ahead deterministic real-time scheduling optimization (RTSO). DASO simulation results are used as the base starting-point values in the hour-ahead online rolling RTSO with a 15-minute time interval. RTSO considers energy storage as another source of grid flexibility, to balance out the deviation between predicted and actual net load demand values. Numerical simulations, on the IEEE RTS test system with high wind penetration levels, indicate the effectiveness of the proposed SDMS framework for managing the grid flexibility to meet the net load demand, in both day-ahead and real-time timescales. Results also highlight the adequacy of the framework to adjust the scheduling, in real-time, to cope with large prediction errors of wind forecasting.

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

Thermal Analysis of Water Cooled ISG Based on a Thermal Equivalent Circuit Network

  • Kim, Kyu-Seob;Lee, Byeong-Hwa;Jung, Jae-Woo;Hong, Jung-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.893-898
    • /
    • 2014
  • Recently, the interior permanent synchronous motor (IPMSM) has been applied to an integrated starter and generator (ISG) for hybrid electric vehicles. In the design of such a motor, thermal analysis is necessary to maximize the power density because the loss is proportional to the power of a motor. Therefore, a cooling device as a heat sink is required internally. Generally, a cooling system designed with a water jacket structure is widely used for electric motors because it has advantages of simple structure and cooling effectiveness. An effective approach to analyze an electric machine with a water jacket is a thermal equivalent network. This network is composed of thermal resistance, a heat source, and thermal capacitance that consider the conduction, convection, and radiation. In particular, modeling of the cooling channel in a network is challenging owing to the flow of the coolant. In this paper, temperature prediction using a thermal equivalent network is performed in an ISG that has a water cooled system. Then, an experiment is conducted to verify the thermal equivalent network.

전기동력 무인기용 하이브리드 추진시스템 비행시험 (Flight Test of Hybrid Propulsion System for Electrically Powered UAV)

  • 박부민;김근배;차봉준
    • 한국추진공학회지
    • /
    • 제17권4호
    • /
    • pp.49-55
    • /
    • 2013
  • 한국항공우주연구원 (이하 항우연)에서 개발중인 중형 전기동력 무인기 EAV2의 추진시스템에 대한 비행시험결과에 대하여 기술 하였다. EAV2는 날개 길이 6.9 m, 무게 18 kg의 저속 장기 체공형 무인기이다. 전기 동력원으로는 태양전지, 연료전지, 배터리의 세 가지를 동시에 사용한다. EAV2는 2012년 6월에 22시간 이상 체공 비행에 성공하였다. 시험 결과, 전기추진 시스템은 비행 중 일어나는 여러 상황에서 필요한 동력을 성공적으로 공급하였으며, 각 동력원들은 설계된 목적에 부합하게 작동되었다.

도심항공 모빌리티(UAM)를 위한 틸트 덕티드 팬 형 eVTOL의 초기 사이징 (Initial Sizing of a Tilt Ducted Fan Type eVTOL for Urban Air Mobility)

  • 이상곤;고보성;안성호;황호연
    • 한국항공운항학회지
    • /
    • 제29권3호
    • /
    • pp.52-65
    • /
    • 2021
  • A large amount of time and cost is consumed due to congestions caused by an increasing number of cars which results in a lot of emissions. To overcome these problems, a new electric vertical takeoff and landing (eVTOL) aircraft is being considered. Since vertical take off and landing without a separate runway is realized and electricity is used as a power source, it could solve the saturated ground traffic congestions without emissions. In this paper, the initial sizing was performed based on the Nexus 6HX of Belltextron which is a tilt-ducted fan type. In this study, the electric propulsion system that only uses battery was implemented instead of current Nexus 6HX hybrid electric propulsion. Aerodynamic analyses were performed using OpenVSP and XFLR5. Power-to-weight ratio, wing loading, estimated weight were calculated with these analyses.