• 제목/요약/키워드: Hooked

검색결과 174건 처리시간 0.025초

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

콘크리트 구조체 매입 철근의 직경 및 유형별 앵커력 측정실험 연구 (An Experimental Study on the Anchorage Capacity by Diameter and Anchor Type of Re-bar)

  • 조성열;손기상
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.67-73
    • /
    • 2014
  • Construction equipment such as tower crane should be installed in a field without appropriate anchorage to cause a collapse of crane. The anchorage capacity can be varied with Anchor length, concrete strength, anchor diameter, hooked or non hooked these variables will be made and tested in the study. It is shown what anchorage capacity will be more effective case by case. Hooked and non-hooked rebar anchor concrete weight with dia 22mm rebar are shown with initial displacement at 170~220KN of hooked case and 200~210KN of non-hooked one which are linearly increased, without any ductility behavior with almost brittleness. Three(3) same test pieces are almost similarly behaviored without relation to hooked or non-hooked cases. It is found out that the bigger diameter of rebar becomes, the more resistant capacity could be made, but conversely ductility against sudden collapse similar to brittleness becomes the more insufficient. It is also found out that dia 16mm rebar could be more effectively applied to heavy support weight at construction sites.

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

외측 보-기둥 접합부의 정착 상태에 관한 훅크철근의 영향 (Effects of the Number of Hooked Bars on Anchorage Conditions at Exterior Joints)

  • 최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권2호
    • /
    • pp.151-156
    • /
    • 1997
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of the number of hooked bars of joint area were investigated. Under the pull-out action of hooked bars, the damage and cracking of joint area tends to be more extensive as the number of hooks pulling out from a joint increases. The pull-out strength and post-peak ductility of hooked bar are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at exterior joints.

  • PDF

Experimental Investigation on the Blast Resistance of Fiber-Reinforced Cementitious Composite Panels Subjected to Contact Explosions

  • Nam, Jeongsoo;Kim, Hongseop;Kim, Gyuyong
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.29-43
    • /
    • 2017
  • This study investigates the blast resistance of fiber-reinforced cementitious composite (FRCC) panels, with fiber volume fractions of 2%, subjected to contact explosions using an emulsion explosive. A number of FRCC panels with five different fiber mixtures (i.e., micro polyvinyl alcohol fiber, micro polyethylene fiber, macro hooked-end steel fiber, micro polyvinyl alcohol fiber with macro hooked-end steel fiber, and micro polyethylene fiber with macro hooked-end steel fiber) were fabricated and tested. In addition, the blast resistance of plain panels (i.e., non-fiber-reinforced high strength concrete, and non-fiber-reinforced cementitious composites) were examined for comparison with those of the FRCC panels. The resistance of the panels to spall failure improved with the addition of micro synthetic fibers and/or macro hooked-end steel fibers as compared to those of the plain panels. The fracture energy of the FRCC panels was significantly higher than that of the plain panels, which reduced the local damage experienced by the FRCCs. The cracks on the back side of the micro synthetic fiber-reinforced panel due to contact explosions were greatly controlled compared to the macro hooked-end steel fiber-reinforced panel. However, the blast resistance of the macro hooked-end steel fiber-reinforced panel was improved by hybrid with micro synthetic fibers.

Off-hooked 트레일러 시스템의 궤적 추종 (Path following of the passive off-hooked trailer system)

  • 이재형;박명국;정우진;김문상;송재복
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1831-1839
    • /
    • 2003
  • This paper deals with design and control of passive multiple trailer systems fer practical applications. Due to cost and complexity of trailer mechanism, passive systems are preferred to active systems in this research. The control objective is to minimize trajectory tracking errors of passive multiple trailers. Three types of passive trailer systems-direct-hooked, three-point, and off-hooked- are discussed in this paper. Trajectory tracking performance and stability issues under constant velocity motion are carried out for three types. Various simulations and experiments have been also performed for these three types. It is shown that the proposed off-hooked trailer system produces better tracking performance than the other types.

콘크리트 강도별 매입 철근의 유형별 부착력 측정실험 (An Experimental Study on Bonding Capacity by Concrete Strength and Type of Re-bar Anchor)

  • 조성열;손기상
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 2015
  • Many construction equipment or supporting structure should be installed in a field without appropriate anchorage to cause a collapse of those. Anchor length, anchor diameter, hooked or non hooked will be made and tested in the study. This one will be analyzed and compared with the previous study in order to find out some difference, strength by strength, based on this study. Embedded re-bar and the resistant capacity against pulled out force of re bar have been tested and analyzed by concrete design strength and rebar diameter in the study. 21Mpa and 24MPa compressive strength which are used in construction practice have been applied as variables. Those rebars are composed of D13, D16. D22 which are mostly used at construction sites. The followings are summarized as conclusions.1) ductility is not increased as rebar diameter becomes larger under the condition of non-hooked anchorage.2) those are two times of displacement difference between small diameter of rebar and large one with hooked anchorage of rebar while being 1/10 times difference with non-hooked condition but, only 10% difference of maximum load are shown, not conspicuously between hooked and non-hooked condition.3) displacement related to ductility can be three(3) times decreased if only concrete compressive strength and rebar diameter become larger with heavy support weight.

후크형 강섬유와 PVA섬유를 하이브리드 보강한 시멘트복합체의 인장특성에 미치는 변형속도의 영향 (Strain Rate Effect on tensile properties of Hooked Steel Fiber and PVA Fiber hybrid reinforced cementitious composites)

  • 손민재;김규용;이상규;김경태;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.208-209
    • /
    • 2018
  • In this study, the tensile properties of hybrid fiber reinforced cementitious composites under the high strain rate was evaluated. Experimental results, the HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. Also, the fracture toughness was greatly improved because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance performance of hooked steel fiber at strain rate 101/s.

  • PDF

A Passive Multiple Trailer System with Off-axle Hitching

  • Lee, Jae-Hyoung;Woojin Chung;Kim, Munsnng;Song, Jae-Bok
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권3호
    • /
    • pp.289-297
    • /
    • 2004
  • This paper deals with the design and control of passive multiple trailer systems for practical applications. Due to the cost and complexity of the trailer mechanism, passive systems are preferred to active systems in this research. The design and control objective is to minimize the trajectory tracking errors occurring in passive multiple trailers. Three sorts of passive trailer systems, off-hooked, direct-hooked, and three-point, are discussed in this paper. Trajectory tracking performance and stability issues under constant curvature reference trajectories are investigated for these three types. As well, various simulations and experiments have been performed for each type. It is shown that the proposed off-hooked trailer system produces a tracking performance that is superior to the others.

변형속도에 따른 폴라아미드 섬유 및 후크형 강섬유 보강 시멘트 복합체의 인장특성 (Tensile Properties of Polyamide Fiber and Hooked Steel Fiber Reinforced Cementitious Composites by Strain Rate)

  • 이상규;김규용;황의철;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2018
  • In this study, it evaluate the tensile properties of polyamide fiber reinforced cementitious composite and hooked steel fiber reinforced cementitious Composites by strain rate. Polyamide fiber reinforced cement composites (PAFRCC) and Hooked Steel Fiber Reinforced Cement Composite(HSFRCC) were fabricated. Each specimen was reinforced with 1.0 and 2.0vol% fiber. The length of the reinforced fiber was 30 mm for both fibers, and the tensile test specimen was made in dumbbell shape. As a result, the tensile strength of fiber in polyamide fiber and the mechanical bonding between fiber and matrix in hooked steel fiber are considered to be the main factors affecting tensile behavior of fiber reinforced cement composite.

  • PDF