• Title/Summary/Keyword: High-frequency floor

Search Result 145, Processing Time 0.025 seconds

Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions (고진동수 지진동에 대한 원전 기기의 지진취약도 분석)

  • 최인길;서정문;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF

A Review of Experimental Evaluation Method to Floor Environment Vibration Criteria for Semiconductor and Display Equipment (반도체·디스플레이 장비용 바닥 환경진동허용규제치의 실험적 평가방법 고찰)

  • An, Chae Hun;Choi, Jeong Hee;Park, Joon Soon;Park, Min Su
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.25-31
    • /
    • 2021
  • The semiconductor and display equipment demands an ultra-fine precision of several nm to several ㎛, and the scale is getting smaller due to the explosive development. The manufacturing process equipment for such products with ultra-fine precision is very sensitive to ultra-small vibrations flowing from the floor, resulting in problems of production defects and yield degradation. The vibration criteria are a standard that regulates the vibration environment of the floor where such precision process equipment will be installed. The BBN vibration criteria defined the allowable vibration velocity level in the frequency domain with a flat and inclined line and presented a rating according to it. However, the actual vibration criteria have appeared with various magnitudes in the frequency domain according to the dynamic characteristics of individual equipment. In this study, the relationship between the relative motion of two major points in the equipment and the vibration magnitude of the floor is presented using the frequency response function of a simple 3-DOF model. It is describing the magnitudes according to the frequency of the floor vibration that guarantees the allowable relative motion and this can be used as the vibration criteria. In order to obtain the vibration criteria experimentally a method of extracting through a modal test was introduced and verified analytically. It provides vulnerable frequency and magnitude to floor vibration in consideration of the dynamic characteristics of individual equipment. And it is possible to know necessary to improve the dynamic characteristics of the equipment, and it can be used to check the vibration compatibility of the place where the equipment will be installed.

A Study on Mount Performance for Structure-Borne Noise Reduction in Resiliently Mounted System (탄성지지된 시스템의 마운트 고체음저감 성능에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2E
    • /
    • pp.50-55
    • /
    • 2007
  • SBN (Structure-Borne Noise) reduction in resiliently mounted machineries are predicted by using mass-spring model and wave model. In mass-spring model, mount is modeled as a spring, while in wave model, mount is considered as an equivalent elastic rod for taking account into longitudinal wave propagation. The predictions for SBN reduction through mounts are compared to the measurements for four different pumps. It is found that the mass-spring model is valid only in low frequency range below few hundred Hz, while for high frequency ranges longitudinal wave propagation in the mount must be considered to explain the measurements. It is also shown that impedance of the floor slightly affects low frequency behaviour in mass-spring and wave model below 50 Hz - 80 Hz, so that in engineering practice the effect of floor impedance may be neglected in computing mount performance.

Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P (F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책)

  • Jeong, Jeong-Ho;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeon, Jin-Yong;Jo, A-Hyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF

Sound Insulation Performance of the Layered Structure of the Next Generation High Speed Train (차세대 고속철도 차량 적층 구조의 차음성능)

  • Lee, Jung-Hyeok;Kim, Seock-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.326-331
    • /
    • 2011
  • Aluminum extruded panel used in a high speed train shows high stiffness, however, its sound insulation performance is remarkably decreased by local resonance phenomena. In this paper, improvement strategy of the sound insulation performance is proposed for the floor extruded panel used in HEMU-400x, 400km/h class next generation high speed train under development, and the improvement effect is verified by experiment. Aluminum extruded panel specimen for the floor is manufactured and urethane foam is installed in the core of the panel. Based on ASTM E2249-02, intensity transmission loss is measured and the improvement effect in local resonance frequency band is verified. Finally, improvement effect of the sound insulation performance is estimated on the layered floor structure including the foamed aluminum panel.

  • PDF

The Influence of the floor rigidity on front-loading washer installation and its vibrational behavior (설치면 강성에 따른 드럼세탁기의 동특성 및 설계대책)

  • Wee, Hoon;Cheong, J.D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.248-251
    • /
    • 2004
  • The vibrational behavior of a front load washing machine is heavily influenced by the floor stiffness on which the washing machine is installed. In case the floor stiffness is extremely low like a wooden floor (we call it a 'soft floor, S/F'), it is quite probable that a washer's rigid body mode exists in the operating frequency range. In this case, the outer frame vibration level would be very high, but the mitigation scheme is quite limited except the excitation force abatement by acquisition of the optimal inertia in the internal vibratory system and the diaphragm's stiffness with the minimum force transfer.

  • PDF

Psychophysical and Physiological Study on Various Lifting Tasks (여러 가지 들기 작업에서의 인체심리학적 · 생리학적 연구)

  • Yun, Hun-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.11-22
    • /
    • 2006
  • The muscular-skeletal disorders(MSDs) that have become a major issue recently in Korean industrial safety area are mainly caused by manual material handling task. The objective of this study is to provide scientific data for the establishment of work safety standard for Korean workers through the experiments of lifting task under various conditions, in order to prevent the muscular-skeletal disorders in the industrial work site. Eight male college students were recruited as participants. Three different lifting frequencies(1, 3, 5 lifts/min) and three twisting angles(including the sagittal plane and two asymmetric angles; i.e., 0°, 45°, 90°) for symmetric and asymmetric tasks, respectively, with three lifting range from floor to knuckle height, knuckle to shoulder, floor to shoulder height for one hour's work shift using free style lifting technique were studied. The maximum acceptable weight of load(MAWL) was determined under the different task conditions, and the oxygen consumption, heart rate, and RPE were measured or recorded while subjects were lifting their MAWLs. The results showed that: (1) The MAWLs were significantly decreased as the task frequency and task angle increased.; (2) The heart rate, oxygen consumption, RPE significantly increased with an increase in lifting frequency although maximum acceptable weight of lift decreased.; (3) The highest heart rate and oxygen consumption was recorded at the lifting range of floor to shoulder, followed by floor to knuckle and knuckle to shoulder.; (4) The RPE value showed that subjects perceived more exertion at the high frequency rate of lifting task and lifting range of floor to shoulder height. (5) The modeling for MAWL using isometric strength, task angle and lifting frequency were developed. It is expected that use of the results provided in this study may prove helpful in reducing MMH hazards, especially from lifting tasks for Korean, and can be used as a basis for pre-employment screening.

Vibration Characteristics of the Floor Structures Inserted with Damping Materials (제진재가 삽입된 바닥 구조의 진동특성에 대한 실험연구)

  • Jeon, Jin-Yong;Jeong, Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1036-1043
    • /
    • 2006
  • Damping materials for reducing heavy-weight floor impact noise in reinforced concrete structures were tested in apartment buildings. The effect of damping materials and an impact isolator were compared with an on-site experiment conducted in a high-rise apartment building. The loss factor of damping material analyzed more than 2 times than rubber to $1.5{\sim}2.3$, could know that Damping layer has excellent attenuation performance in side of vibration reduction. The results showed that the resonance frequency increased but vibration acceleration level decreased when the damping materials were used. The heavy-weight impact sound levels of the structure decreased substantially at 63 Hz, whereas the sound levels of the structure with the impact isolator increased.

Formula for Equivalent Impulsive Force to Predict Vibrational Response of High-frequency Staircases (고진동수 계단의 진동응답 산정을 위한 등가임펄스 산정식 제안)

  • Kim, Na Eun;Lee, Cheol Ho;Kim, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.181-193
    • /
    • 2015
  • High-frequency staircases are widely used nowadays to meet aesthetics and functionality needed in modern architecture. Unfortunately, no design guide is available in domestic practice to predict response or evaluate the vibration performance of high-frequency staircases. SCI-P354 published by the Steel Construction Institute of UK provides the formula for effective impulsive force. However, this formula was shown to overestimate the response of high-frequency staircases excited by fast ascending and descending over 2.2Hz pace frequency because it was developed based on the walking test in a slow pace frequency. This study proposes a semi-analytical formula to predict the response of stiff staircases based on analytical and experimental studies of response acceleration for various walking frequencies covering 1.4~4.5Hz.

Research about correlation of slab vibration mode and heavy-weight floor impact sound (슬래브의 동특성과 중량충격음의 상관관계에 관한 연구)

  • Chung, J.Y.;Lee, S.W.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF