• 제목/요약/키워드: High-Dose

검색결과 4,246건 처리시간 0.029초

Interpretation of Animal Dose and Human Equivalent Dose for Drug Development

  • Shin, Jang-Woo;Seol, In-Chan;Son, Chang-Gue
    • 대한한의학회지
    • /
    • 제31권3호
    • /
    • pp.1-7
    • /
    • 2010
  • Objectives: To introduce to TKM scientific dose conversion methods of human to animal or animal to human for new drug investigations. Methods: We searched guidelines of the FDA and KFDA, and compared them with references for drug-dose conversion from various databases such as PubMed and Google. Then, we analyzed the potential issues and problems related to dose conversion in safety documentation of new herbal drugs based on our experiences during Investigational New Drug (IND) applications of TKM. Results: Dose conversion from human to animal or animal to human must be appropriately translated during new drug development. From time to time, investigators have some difficulty in determining the appropriate dose, because of misunderstandings of dose conversion, especially when they estimate starting dose in clinical or animal studies to investigate efficacy, toxicology and mechanisms. Therefore, education of appropriate dose calculation is crucial for investigators. The animal dose should not be extrapolated to humans by a simple conversion method based only on body weight, because many studies suggest the normalization method is based mainly on body surface area (BSA). In general, the body surface area seems to have good correlation among species with several parameters including oxygen utilization, caloric expenditure, basal metabolism, blood volume and circulating plasma protein. Likewise, a safety factor should be taken into consideration when deciding high dose in animal toxicology study. Conclusion: Herein, we explain the significance of dose conversion based on body surface area and starting dose estimation for clinical trials with safety factor.

웹 기반 표준한국인 장기 흡수선량 및 유효선량 평가 시스템 개발 (Development of Reference Korean Organ and Effective Dose Calculation Online System)

  • 박수연;염연수;김재현;이현수;한민철;정종휘;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.30-37
    • /
    • 2014
  • 최근 표준한국인 성인남녀 복셀 팬텀 한 쌍인 High-Definition Reference Korean-Man (HDRK-Man)과 High-Definition Reference Korean-Woman (HDRK-Woman)을 개발한 바 있다. HDRK-Man과 HDRK-Woman은 각각 한국인 성인 남성과 여성을 대표하므로 이들을 이용하면 한국인 고유의 유효선량을 계산할 수 있다. 이러한 한국인 고유의 유효선량을 계산하기 위해서는 표준한국인 팬텀을 이용한 몬테칼로 선량계산을 수행하여야 한다. 하지만 이러한 몬테칼로 선량계산은 전산인체모델에 대한 이해와 고도의 몬테칼로 전산모사 기술이 요구되기 때문에 몬테칼로 전산모사 경험이 적은 연구자들에게는 접근성이 용이하지 않다. 최근 UFPE (Federal University of Pernambuco) 연구팀에서는 몬테칼로 선량계산 온라인 시스템인 CALDOSE_X를 운영하고 있다. CALDOSE_X는 사용자가 온라인상에서 직접 입력한 선원조건에 따라 곧바로 몬테칼로 선량계산을 수행하고 계산된 결과를 제공해주는 온라인 서비스이다. 따라서 CALDOSE_X를 이용하면 몬테칼로 전산모사 경험 없이도 누구나 쉽게 원하는 선원조건에 대한 선량계산을 수행할 수 있다. 하지만 CALDOSE_X에서 제공하는 선량값은 서양인 전산팬텀을 이용하기 때문에, 이를 한국인 종사자에 대한 방사선 방호목적으로 사용하기에는 여전히 한계가 있다. 이에 본 연구에서는 온라인상에서 사용자가 입력한 선원조건에 따라 실시간으로 표준 한국인에 대한 유효선량을 계산할 수 있는 웹 기반 표준한국인 선량평가 시스템을 구축하였다.

국립공원의 해발고도에 따른 환경방사선 측정 (Measurement of Environmental Radiation according to Altitude above Sea Level in National Park)

  • 지태정;이인식
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.694-701
    • /
    • 2012
  • 본 연구는 국가환경방사선 자동감시망이 설치되지 않은 국립공원의 산악 지역을 대상으로 환경방사선을 측정하였다. 측정 방법은 지표 1m 높이에서 공간선량과 지표면에서의 지표선량을 측정하였다. 국립공원 선정은 중부지역과 남부지역을 같은 분포로 하여 전국에 10곳을 선정하였다. 측정장비는 감마선측정에 활용되는 INTERCEPTOR$^{TM}$(Thermo, USA, 2006)를 사용하였다. 방사선측정은 국립공원 입구와 정상에서는 필수적으로 측정하였고, 그 외 지점은 해발 고도를 500m 단위로 구분하여 탐방객이 많이 다니는 곳에서 측정하였다. 측정횟수는 각 지점에서 2분간 장비를 안정시킨 후 5회 이상 측정하였다. 측정결과, 공간감마선량의 경우 1,000m 이하 국립공원에서는 해발 고도 500m 지점에서 높은 선량이 측정되었다. 그 중 북한산, 계룡산, 월출산에서 $0.23{\mu}Svh^{-1}$ 이상인 것으로 확인되었다. 1,000m 이상의 국립공원에서는 설악산 1,500m 지점에서 $1.77{\mu}Svh^{-1}$로 측정되어 백그라운드 기준 선량보다 10배 이상 증가하였다. 선량에 유의한 변화를 보이지 않은 국립공원은 내장산, 소백산, 지리산으로 확인되었다. 환경방사선량이 낮게 측정된 산은 가야산 정상(1,430m)에서 $0.04{\mu}Svh^{-1}$, 한라산 정상(1,950m)에서 $0.03{\mu}Svh^{-1}$인 것으로 확인되었다. 지표선량 측정에서도 중간 높이인 500m, 1,000m에서 높게 측정되었다. 지각 구성물질의 종류에 따른 측정에서는 암석으로 구성된 국립공원에서 높은 선량으로 조사되었으며, 화산활동이 일어났던 한라산에서는 환경방사선량이 낮게 측정되었다.

관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도 (Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT)

  • 김연민
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1033-1039
    • /
    • 2023
  • 폐 스크리닝 검사로 이용되고 있는 저선량 흉부 CT는 Scan 범위 내에 관상동맥 석회화에 대한 정보도 함께 포함하고 있어 이를 이용한 관상동맥 석회화 판별의 유용성을 알아보고자 한다. 저선량 흉부 CT 검사와 관상동맥 석회화 점수(CACS) 검사를 같은 날 시행 받은 자들을 대상으로 하였다. 관상동맥 석회화 점수 검사 결과를 Coronary artery calcium score categories and risks 분류법을 참고하여 4개 그룹(Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS)으로 각각 30명을 선정한 후 관상동맥 석회화 수치 측정 업무에 종사하고 있는 경력 15년차 이상 5명의 방사선사가 저선량 흉부 CT 영상에서 관상동맥 석회화 유무를 후향적으로 분석하였다. 저선량 흉부 CT 영상에서 5명의 관찰자가 통일되게 판독한 결과가 관상동맥 석회화점수 CT 검사 결과와 일치한 경우는 Low 그룹: 56%, Mild 그룹: 96.6%, Moderate 그룹: 100%, High 그룹: 100%로 나타났다. Low 그룹에서 5명의 관찰자 모두가 석회화를 관찰한 것은 30건 중 17건이었으며, 5명이 모두 판별 불가로 결정한 경우 7건이었다. 무증상 성인을 대상으로 저선량 흉부 CT 검사에서 석회화 점수가 15 이상인 경우에는 관상동맥 석회화를 100% 관찰할 수 있었다. 판별이 가능한 최소 석회화 수치는 1로, 피검자의 체형이 작거나 심장의 움직임이 최소가 되는 시점에서 스캔이 이루어지는 경우 매우 작은 석회화까지도 판별할 수 있다는 것을 알 수 있었다.

Assessment of Radiation Dose from Radioactive Wedge Filters during High-Energy X-Ray Therapy

  • Back, Geum-mun;Park, Sung Ho;Kim, Tae-Hyung
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.45-48
    • /
    • 2017
  • This paper evaluated the amount of radiation generated by wedge filters during radiation therapy using a high-energy linear accelerator, and the dose to the worker during wedge replacement. After 10-MV photon beam was irradiated with wedge filter, the wedge was removed from the linear accelerator, and the dose rate and energy spectrum were measured. The initial measurement was approximately 1 uSv/h, and the radiation level was reduced to 0.3 uSv/h after 6 min. The effective half-life derived from the dose rate measurement was approximately 3.5 min, and the influence of AI-28 was about 53%. From the energy spectrum measurements, a peak of 1,799 keV was measured for AI-28, while the peak for Co-58 was not measured in the control room. The peaks for Au-106 and Cd-105 were found only measurement was done without wedge removement from the linear accelerator. The additional doses received by the radiation worker during wedge replacement were estimated to be 0.08-0.4 mSv per year.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

랫드에서 인체 재조합 적혈구 조혈인자, rHu-EPO의 아급성정맥독성시험 (Subacute Intravenous Toxicity Study of Recombinant Human Erythropoietin(rHu-EPO) in Rats)

  • 김형식;곽승준;천선아;임소영;박현선;홍채영;김원배;김병문;안병옥
    • Toxicological Research
    • /
    • 제12권2호
    • /
    • pp.309-318
    • /
    • 1996
  • This study was conducted to investigate the subacute intravenous toxicity of rHu-EPO in Sprague-Dawley rats. rHu-EPO was daily administered to male and female rats for 30 days with different dose levels(100, 500, 2,500 unit/ kg). After the administration period of 30 days, 5 males and 5females rats per each dose group were assigned for recovery period of additional 30 days. There were no clinical signs compared with control group but slight decrease in spontaneous motor activities and locomotions were observed at high dose groups of males and females. In males, feed consumption was reduced at 500 unit/kg and body weight gain was retarded. In the administration sites of tail, focal congestion was observed in a few animals treated with rHu-EPO. No deaths were occurred during the course of study. In hematological examination. a significant increase of hemoglobin and hematocrit was observed in the males and females rats receiving high dose of rHu-EPO. rHu-EPO administration for 30 days showed a marked decrease in glucose concentration. At the highest dose groups, there was a significant incerase in the weights of spleens in both sexes. but this was considered to be related to its pharmacological activity. These results indicate that rHu-EPO does not induce any significant toxic effect on Sprague-Dawley rats for 30 days.

  • PDF

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

퇴적 환경에 따른 루미네선스 신호의 특성 (Characteristics of Luminescence Signals According to the Depositional Environment)

  • 홍성찬;최광희
    • 한국지형학회지
    • /
    • 제28권2호
    • /
    • pp.59-70
    • /
    • 2021
  • This study aims to determine the sunlight exposure according to depositional environment to improve the accuracy of optically simulated luminescence (OSL) dating. Sufficient sunlight exposure during transportation of sediment is a basic assumption of the OSL dating, and if the process does not occur enough, the results may be overestimated compared to the actual depositional age. Therefore, the main purpose of this study is to establish a correction method by determining residual or unbleachable dose after sunlight exposure in the actual deposition process, not in the laboratory measurement. Four samples from two sites were collected according to the depositional environment from rivers and coasts, and various OSL signals, including the size of residual dose, degree of dispersion between grains, and OSL signal sensitivity, were measured. As a result, it was confirmed that sediments formed under temporarily high energy environments, such as floods and surges, had relatively high residual dose or large dispersion of residual dose between particles. In further studies, the OSL signal characteristics of river sediments by flow velocity will be identified and the relationship between energy and OSL signal characteristics will be identified in more detail. Moreover, a method of reconstructing the paleo-environment at the time of deposition for existing sediments will be devised. It is expected to provide important information for the frequency of disaster recurrence and prediction of future climate change.

HRccine(HFRS-virus vaccine)의 Rat에서의 아급성독성 (Subacute Toxicity of HRccine (HFRS-virus vaccine) in Rats)

  • 조효진;백영옥;임동문;최재묵;김달현;박관하;조정식;이영순
    • Toxicological Research
    • /
    • 제11권1호
    • /
    • pp.137-145
    • /
    • 1995
  • HRccine was administered subcutaneously to rats for 4 weeks at dose levels of 300, 60 and 12 times the expected clinical dose to evaluate the subacute toxicity. There were no treatment-related effects in clinical signs, body weight changes, food consumption, water consumption, urinalysis and blood biochemistry in any dose groups. In hematological examinations, increase of leucocyte counts and decrease of hemoglobin concentration were observed in the high dose-treated group. However, no treatment-attributable pathological changes were observed in microscopic examinations. The no-effect dose in subacute toxicity study of rats was considered to be 300 times the expected clinical dose.

  • PDF