• Title/Summary/Keyword: High flowing concrete

Search Result 141, Processing Time 0.04 seconds

An Experimental Study on the Strength of Concrete Using the Belite Cement (벨라이트시멘트를 사용한 콘크리트의 강도특성에 대한 실험적 연구)

  • 문한영;문대중;하상욱;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.61-64
    • /
    • 1997
  • As construction technology advances, most of concrete structures are becoming larger and taller. Therefore, high strength and quality concrete is necessary for them. So, the proposal of using belite cement is investigated to satisfy high flowing, low heat, and high strength. In this study, the compressive strength, tensile strength, and modulous of elasticity of concrete using belite cement was considered according to the mix proposition condition as a water-cement ratio, unit cement content, and sand percentage.

  • PDF

The Study for the Air Bubble Deterioration of Combined High Flowing Self-Compacting Concrete (병용계 고유동 자기충전콘크리트의 기포저감을 위한 연구)

  • Choi, Yun-Wang;Kim, Kyung-Hwan;Ruy, Deug-Hyun;Jeong, Jae-Gwon;Kang, Hyun-Jin;Lee, Jae-Nam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.449-452
    • /
    • 2008
  • This study is to manufacture HSCC (High flowing Self-Compacting Concrete) be able to construction without vibration & hardening, and it is stable according to the change of the surface number of aggregate and to examine the factor of reduction occurred before after hardening through the indoor experiment. It is essential to use of the thickener to increase the viscosity in the combined HSCC. In this result, it make more bubbles than HSCC of pulverulent body. The result of study has shown, through the surface air bubble by not passed air bubbles within concrete after hardening, It has bad effect in not only appearance of structures but strength & duration. It is the experiment for air bubble of concrete according to the types of aggregate (fine aggregate), mixing time of concrete, exfoliation, material of model form and so that reduce the air bubble of combined HSCC. Experiments have shown, the effect of exfoliation was bigger than the effect of form for the performance of surface finishing of combined HSCC after hardening according to the exfoliation or material of model form and the opaque guris has good condition of finishing.

  • PDF

Development of Flowability Measurement Device using Laser Diode (레이져 다이오드를 이용한 유동성능 측정장치 개발)

  • Jeong, Jae-Gwon;Kim, Kyung-Hwan;Eom, Joo-Han;Choi, Yun-Wang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.247-248
    • /
    • 2009
  • Testing standards both nationally and abroad for high flowing concrete are presented about slump flow and the time to reach 500 mm. However, the slump flow testing method to measure flow properties of high flowing concrete results in measurement error due to the differences in each person's perception of the test. This study introduced laser diode to reduce such testing errors from personal differences in experimental procedure.

  • PDF

Properties of Water Content Variances in Ultra High Flowing Concrete Before and After the Pumping Operation (현장적용 초유동 콘크리트의 펌프압송 전후 단위수량 변화 특성)

  • Kim, Kyoung-Min;Yoo, Jae-Kang;Shin, Hong-Cheol;Choi, Jong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.401-404
    • /
    • 2006
  • This study is the part of the investigation of the state of the art in ultra high flowing concrete (UHFC), applied in practical field construction, in order to develop the technology for improving workability. This paper includes a brief introduction of water content variance properties in UHFC before and after the pumping operation. Test showed that water content in all parameters decreased after the pumping. This is due to the increase of an absorption ratio of coarse aggregate by the pressure of the pumping operation. thus decreasing the water content. Therefore it should be considered to find out the possibility, which can improve the workability, suffering from over viscosity by the lower water content, in field construction.

  • PDF

Flowability and Strength Properties of High Flowing Self-Compacting Concrete Using for Tunnel Lining

  • Choi, Yun-Wang;Choi, Wook;Kim, Byoung-Kwon;Jung, Jea-Gwone
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.145-152
    • /
    • 2008
  • So far, there has been no study of the concrete to strengthen in the lining of the tunnels, except for the study of the stability of subgrade and the tunnel construction technologies. In the existing concrete work for tunnel lining, lots of problems happen due to the partial compaction and the material segregation after casting concrete. Accordingly, the aim of this study is to improve economic efficiency and secure durability through the improvement of the construction performance and quality of the concrete for the tunnel lining among the civil structures. Therefore, the compactability and strength properties of the High Flowing Self-Compacting Lining Concrete (HSLC) are evaluated to develop the mixing proportion for design construction technology of HSLC that can overcome the inner cavity due to the reduced flowability and unfilled packing, which has been reported as the problem in the existing lining concrete. The result of the evaluation shows that the ternary mix meets the regulations better than the binary mix. Consequently, it has been judged applicable to the cement for tunnel lining.

The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete (고유동 자기충전 콘크리트와 이형철근의 부착특성)

  • Choi, Yun Wang;Jung, Jea Gwone;Kim, Kyung Hwan;An, Tae Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.511-518
    • /
    • 2009
  • This study was intended to compare and evaluate the adhesion of High flowing Self-compacting Concrete (HSCC), Conventional Concrete (CC) and deformed bar based on concrete strength 3 (30, 50 and 70 MPa), among the factors affecting the bond strength between concrete and rebar, after fabricating the specimen by modifying the rebar position at Horizontal reinforcement at bottom position (HB), horizontal reinforcement at top position (HT) and vertical reinforcement type (V). As a result of measuring bond strength of HB/HT rebar to evaluate the factor of the rebar at top position, the bond strength of HB/HT rebar at 50 and 70 MPa was 1.3 or less and at 30 MPa, HSCC and CC appeared to be 1.2 and 2,1, respectively. Thus, when designing the anchorage length according to the concrete structure design standard (2007) at HSCC 30, 50 and 70 MPa, it would be desirable to reduce the correction factor of anchorage length of the horizontal reinforcement at top position, which is suggested for the reinforcement at top position, to less than 1.3 of CC.

The required performance of the super flowing concrete for LNG (LNG tank용 초유동 콘크리트의 배합설계)

  • 권영호;전성근;백승준;이용일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.463-468
    • /
    • 1999
  • The slurry wall of Inchon LNG receiving terminal tank will be planned the super flowing concrete having properties of high strength (required strength 520kg/$\textrm{cm}^2$), no-vibrating and massive structure in the underground. For the performance of this concrete, we investigate and select all materials, the optimum mix design and sensibility test in the laboratory. As test results, we choose portland blast-furnace slag cement and lime stone powder(L.S.P) as cementitious materials, W/C 41%(W/B 35.4%), S/a 50.8% and unit volume of coasre aggregate 0.30 as optimum mix design. Also test result of the fresh and hardened concrete are satisfied with specifications of slurry wall.

  • PDF

The Practical Application on the Super Flowing Concrete using Manufactured Sand (부순모래를 사용한 초유동 콘크리트의 현장적용)

  • Park, Chil-Lim;Kwon, Yeong-Ho;Lee, Sang-Soo;Won, Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.9-14
    • /
    • 1998
  • In this paper, we described the basic elements(flowabiligy, fillingability, elapsed time, pumpability, no-vibrating effects, and etc.) required for the application and quality control of the super flowing concrete(SFC) in Top Down site. Also, manufactured sand and fly ash were used for investigating characteristics of SFC through various experiments(mix design, optimum mix condition) before placing the concrete in site. As a result of this project, the developed SFC shown high flowability and self-fillingability in the joint good enough for the requirement. Futhermore, inner uniformity of the no-vibrated concrete was verified by testing reformed space. Therefore, quality control and compressive strength(360kg/$\textrm{cm}^2$) can be secured by using SFC even without vibrating.

  • PDF

The Practical Application on Super Flowing Concrete (Inchon subway 1-10 section) (초유동 콘크리트의 적용사례)

  • 박칠림;김성원;안재현;권영호;이상수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.916-921
    • /
    • 1998
  • This study describes the result for the placement of the super flowing concrete(SFC) in under-pinning-top-slab which is located Inchon subway section 1-10 where, due to heavy reinforcements and limited working space, it was difficult to place concrete. After placing 600㎥, smooth construction and quality control were possible due to the good flow-ability, self-fillingability, and the resistance of segregation of the SFC itself. Furthermore, economical efficiency was obtained through not only the reduction of the works, labors, and site noise but also the efficient construction control. Because of the crack prevention, high strength, and a fine concrete surface, this study could be considered as a momentum to be adopted generally for applying the proposed method to the difficult subway construction area in the near future.

  • PDF

Strength Propreties of Binary and Ternary Blended of Ultra Flowing Self-Compacting Concrete (2성분계 및 3성분계 초유동 자기충전 콘크리트의 강도 특성)

  • Choi, Yun-Wang;Kim, Kyung-Hwan;Ha, Sang-Woo;Moon, Dae-Joung;Kang, Hyun-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.489-492
    • /
    • 2006
  • Needs for the new technologies and cutting-edge Ultra Flowing Self-Compacting Concrete are emerging as the concrete structures are becoming bigger and more specialized recently. In North America and Europe, SCC, which has high resistance against flow ability and segregation, is being used as concrete material in applications such as precast and prestressed bridges, where reinforcing bars are overcrowdedly placed. In Korea, SCC has been utilized limitedly in building structures but its utilization should be expanded to engineering structures such as bridges. In this study, for the application in precast and prestressed bridges with overlycrowded reinforcing bars, USCC was mixed with admixtures to give a binary system and a ternary system according to the 1st grade rules by JSCE (Japan Society of Civil Engineers). Compressive strength and splitting tensile strength of the resulting USCCs were tested. Elastic modulus were compared with the values suggested in CEB-FIP code and ACI 318-05.

  • PDF