• 제목/요약/키워드: Heterodyne laser Interferometer

검색결과 40건 처리시간 0.029초

헤테로다인 레이저 간섭계에서 고속 측정을 위한 주파수 변조 알고리즘 (AFM modulation algorithm for the high speed measurement using a heterodyne laser interferometer)

  • 최현승;윤희선;박기환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.922-925
    • /
    • 2005
  • This article describes a FM modulation algorithm to increase the measurement speed by increasing the beat frequency of the laser without acousto-optic modulator(AOM) in the heterodyne laser interferometer. The proposed algorithm can increase the beat frequency of the heterodyne laser which limit the measurement speed by adjusting a carrier frequency through electronic circuit, while AOM is used to shift the frequency of the heterodyne laser in conventional method. Electronic circuit is constructed to modulate the signals from a laser interferometer and a waveform generator. The brier analysis, the measurement scheme of the system, and the experimental results using a Zeeman-stabilized He-Ne laser are presented. They demonstrate that the proposed algorithm is proven to enhance the measurement speed limit by increasing the beat frequency of the heterodyne laser.

  • PDF

Dual-EKF를 이용한 헤테로다인 레이저 간섭계의 비선형 오차보정 (Nonlinearity error compensation in heterodyne laser interferometer using Dual-EKF)

  • 이상철;이우람;유관호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.310-312
    • /
    • 2009
  • The heterodyne laser interferometer has been widely used in precise measurement field. However, the accuracy is limited by the nonlinearity error caused from incomplete laser sources and nonideal optical components. In this paper, we propose the Dual-EKF which estimates states and weights simultaneously to improve the resolution of heterodyne laser interferometer. As a proof, we demonstrate the effectiveness of our proposed method through experimental results.

  • PDF

2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계 (A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser)

  • 김민석;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF

데이터 퓨전 기법을 이용한 헤테로다인 레이저 간섭계의 오차보정 (Error Compensation in Heterodyne Laser Interferometer using Data Fusion Method)

  • 허건행;성욱진;이우람;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.225-226
    • /
    • 2007
  • In the semiconductor manufacturing industry, the heterodyne laser interferometer plays as an ultra-precise measurement system. However, the heterodyne laser interferometer has some unwanted environmental error which is caused from refraction in the air. This is an obstacle to improve the measurement accuracy in nanometer scale. In this paper we propose a compensation algorithm based on Data Fusion method which reduces the environmental error in the heterodyne laser interferometer. Through some experiments, we demonstrate the effectiveness of the proposed algorithm in measurement accuracy.

  • PDF

신경망 회로를 이용한 레이저 간섭계의 적응형 오차보정 (Adaptive Nonlinearity Compensation in Laser Interferometer using Neural Network)

  • 허건행;이우람;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.86-88
    • /
    • 2007
  • In the semiconductor manufacturing industry, the heterodyne laser interferometer plays as an ultra-precise measurement system. However, the heterodyne laser interferometer has some unwanted nonlinearity error which is caused from frequency-mixing. This is an obstacle to improve the measurement accuracy in nanometer scale. In this paper we propose a compensation algorithm based on RLS(recursive least square) method and artificial intelligence method, which reduce the nonlinearity error in the heterodyne laser interferometer. With the capacitance displacement sensor we get a reference signal which can be transformed into the intensity domain. Using the back-propagation Neural Network method, we train the network to track the reference signal. Through some experiments, we demonstrate the effectiveness of the proposed algorithm in measurement accuracy.

  • PDF

Measurement of electron density of atmospheric pressure Ne plasma jet by laser heterodyne Interferometer with voltage

  • Lim, Jun Sup;Hong, Young June;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.140.1-140.1
    • /
    • 2015
  • Currently, As Plasma application is expanded to the industrial and medical industrial, Low temperature plasma characteristics became important. Especially in Medical industrial, Low temperature plasma directly adapted to human skin, so their plasma parameter is important. One of the plasma parameters is electron density, some kinds of method to measuring electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods is expensive to composed of experiment system. Heterodyne interferometer system is cheap and simple to setting up, So we tried to measuring electron density by Laser heterodyne interferometer. To measuring electron density at atmospheric pressure, we need to obtain the phase shift signal. And we use a heterodyne interferometer. Our guiding laser is Helium-Neon laser which generated 632 nm laser. We set up to chopper which can make a laser signal like a pulse. Chopper can make a 4 kHz chopping. We used Needle jet as Ne plasma sources. Interference pattern is changed by refractive index of electron density. As this refractive index change, phase shift was occurred. Electron density is changed from Townsend discharge's electron bombardment, so we observed phenomena and calculated phase shift. Finally, we measured electron density by refractive index and electron density relationship. The calculated electron density value is approximately 1015~1016 cm-3. And we studied electron density value with voltage.

  • PDF

2-종모드 레이저를 이용한 고분해능 헤테로다인 간섭계 (A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser)

  • 김민석;김승우
    • 한국정밀공학회지
    • /
    • 제19권4호
    • /
    • pp.195-201
    • /
    • 2002
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600~1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with ainus to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial made laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, which allows us to perform multiple measurements of up to 10 machine axes simultaneously.

WLS를 이용한 헤테로다인 레이저 간섭계에서의 비선형 오차 보정 (Nonlinearity Error Compensation in Heterodyne Laser Interferometer using WLS Method)

  • 차형석;이우람;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.271-272
    • /
    • 2007
  • In heterodyne laser interferometer, we use a phase difference between two beams to calculate target's length. However, there exist an nonlinearity error when measuring length in nanoscale. It is caused from frequency-mixed problem of two polarized beams, called cross talks. This fact limits the usefulness of an laser interferometer. To compensate the error, we propose a WLS(weighted least square) algorithm, which will reduce nonlinearity error and make a better optimization in heterodyne laser interferometer.

  • PDF

LMS를 이용한 헤테로다인 레이저 간섭계 비선형성 보정 (Nonlinearlity Compensation of Heterodyne laser interferometer based on LMS)

  • 정필중;이우람;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.283-284
    • /
    • 2007
  • In this paper we introduce a compensation of nonlinearity Heterodyne laser interferometer. The Laser Interferometer is used for length measurement in various industries. However, it has nonlinearity error caused by the imperfect optical equipment. This acts as an obstacle in the measurement improvement. We propose an adaptive error compensation using least mean square(LMS) to improve precision.

  • PDF

정밀 삼차원 측정을 위한 백색광 간섭 광학 프로브 개발 (Optical Probe of white Light Interferometry for Precision Coordinate Metrology)

  • 김승우;진종한;강민구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2002
  • Demand for high precision measurement of large area is increasing in many industrial fields. White-light Scanning Interferometer(WSI) is a well-known method for 3D profile measurement. However WSI has some limitations in a measurement range because of the sensing mechanism. Therefore, in this paper we use a heterodyne laser interferometer to get over the limitations of a short measurement range in WSI, We suggest a new WSI system combined with heterodyne laser interferometer. This system is aimed at eliminating Abbe error with measuring the focus point directly. With the use of triggering functionality of WSI, we can use this system as a probe of a precision stage such as a probe of CMM. The suggested system gives a repeatability of 87 nm in the absolute distance measurement test under the laboratory environment.

  • PDF