• Title/Summary/Keyword: Healthcare Technology

Search Result 1,476, Processing Time 0.023 seconds

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method (측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토)

  • Park, Hee-Won;Shin, Hee-Jung;Kim, Tae-Hoon;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • Purpose: Detection of TSH-binding inhibitor immunoglobulin (TBII) in patients with hyperthyroidism is an important result of Graves' disease (GD) and hyperthyroidism treatment. This has been made out an inspection by commercial radio-receptor assays. To increase the sensitivity and the specificity of the assay, many results of the assay were reported. In this study we evaluated the clinical usetulness of TBII assays by the Comparative method. Material and Methods: We were measured by using healthy control group (n=30, male=20, female=10) of Seoul National University Hospital Healthcare System Gangnam Center from January to March in 2009. Similarly, We were measured by using hyperthyroid (TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL) experimental group (n=58, male=14, female=44) of division of endocrinology and metabolism department of internal medicine Seoul National University Hospital from January to March in 2009. We made a comparative study of each two assays from the first generation to the third generation. We were used of TSAb assay as a measurement of GD diagnostic technique. Results: The specificity of healthy control group was 100% according to the generation. (Specificity=100%, n=30) The sensitivity of hyperthyroid experimental group were the first generation RSR<%> (79.3%, n=58), RSR (51.7%, n=58), the second generation RSR-CT (93.1%, n=58), BRAHMSCT (98.3%, n=58), the third generation ELISA (94.6%, n=56), ECLIA (97.7%, n=58) and TS-Ab<%> (93.5%, n=46). Conclusion: We were used of TSAb assay as a measurement of GD diagnostic technique, The result of data showed a high correlation between the third generation TBII assay and the second generation TBII assay ($R^2$=0.923). Instead of the first generation assay, the second generation assay can be more useful in clincal diagnosis.

  • PDF

Ovarian and Endometrial $^{18}F$-FDG Uptake During the Menstrual Cycle in Normal Premenopausal Patients: Evaluation by PET/CT (월경주기에 따른 $^{18}F$-FDG PET/CT의 자궁 내 섭취에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.43-47
    • /
    • 2009
  • Purpose: The menstrual cycle of normal premenopausal patients was divide into menstrual flow phase, proliferative phase, ovulatory phase, secretory phase. The aim of this study was to ovarian and endometrial $^{18}F$-FDG uptake during the menstrual cycle in normal premenopausal patients. Materials and Methods: We identified 200 incidental $^{18}F$-FDG uptake in the ovary. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery Ste PET/CT system (GE Healthcare, Milwaukee, WI, USA). Ovarian and endometrial $^{18}F$-FDG uptake (expressed as standardized uptake value) was measured on PET/CT image. Results: Two peaks of increased endometrial $^{18}F$-FDG uptake were identified during the menstrual cycle. The $SUV_{avg}$ and $SUV_{max}$ was $2.89{\pm}1.04$ and $3.17{\pm}1.59$ in menstruating patients, $2.4{\pm}0.88$ and $2.98{\pm}1.14$ in proliferative phase patients, $3.59{\pm}1.76$ and $3.17{\pm}1.67$ in ovulatory phase patients, $2.58{\pm}1.39$ and $3.1{\pm}1.8$ in secretory phase patients. Conclusions: Increased ovarian and endometrial $^{18}F$-FDG uptake could be found the time of menstrual flow and ovulatory phase of menstrual cycle. Increased uptake in endometrial adjacent to a cervical tumor does not necessarily reflect endometrial tumor invasion. Since increased uptake was dependent on the menstrual cycle, it can be avoided by scheduling PET/CT just after menstruation. Non-menstrual-related endometrial uptake may be instrumental in establishing a diagnosis in a premenopaual patient.

  • PDF

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Study on the Education Curriculum and Clinical Practice of Medical Technologists (임상병리사 교육과정 및 임상실습에 대한 연구)

  • Yang, Byoung-Seon;Choi, Se-Mook;Shim, Moon-Jung;Kim, Chung-Hwan;Bae, Hyung-Joon;Yook, Keun-Dol;Kim, Yoon-Sik;Lim, Yong;Kang, Ji-Hyuk;Kim, Hong-Sung;Kim, Dong-Chan;Shin, Gyeonghee;Lee, Sang-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.320-330
    • /
    • 2018
  • This study analyzed the curriculum and clinical practicum of the department of clinical laboratory science in Korea. The 2017 educational curricula of all 3-year and 4-year universities were analyzed. Clinical practice was conducted by a questionnaire. As a result of curriculum analysis, the 3-year curriculum was able to grasp the curriculum that focused on the national examinations of medical technologists, and the 4-year curriculum was open to a variety of subjects reflecting the changes in the future, but only at a few universities. In addition, the autonomous enrollment application made it possible to take a national examination without enrolling in courses that students find difficult in major courses. In the case of clinical practice, it was difficult to standardize in various practical institutes, practice periods, and practice credits. Therefore, it will be necessary to standardize the composition of the credits according to the duration of clinical practice and the duration of education. Moreover, is necessary to revise the curriculum in consideration of medical technologist job analysis and clinical field, and it will be necessary to standardize the curriculum and clinical practice model through the Medical Technologist Evaluation Center.

The Effects of Eco-friendly Design of Dishwashing Detergent on Product's Carbon Emission Reduction (친환경 설계로 제조된 주방세제의 탄소배출량 감축 효과)

  • Kim, Jong Seok;Kim, Won Chan;Lee, Yong Ju;Kim, Heung Sik;Park, Heon Young;Yang, Bong Sig;Kim, Wan Soo;Park, Pil Ju;Hong, Eun Ah
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.87-91
    • /
    • 2015
  • As negative effects of climate change have been visualized and its direct damages to economy have been realized, the global efforts to respond to climate change by reducing greenhouse gas emission were accelerated. Korea's Carbon Footprint Labeling gets a lot of attention as one of the effective methods to contribute to national GHG reduction goal, and for enterprises to show customers how much effort the company put into global warming prevention. Consumers' interest on low-carbon products has been increasing. This study uses Life Cycle Assessment method to calculate the amount of carbon emission of dishwashing detergent, LG Household & Healthcare, which reduced carbon emissions by using raw materials that has relatively lower environment load. Life Cycle Assessment Method is based on guidelines of Carbon Footprint Labeling, Ministry of Environment, and pre-manufacturing, manufacturing, and disposal phase are included while use phase of the product is excluded from assessment. In order to understand the effects of eco-design on carbon emissions, the dishwashing detergent's carbon emissions are compared before and after the change of main raw materials. The result shows the improvement from $0.47kgCO_2eq/kg$ to $0.38kgCO_2eq/kg$ per product, and this means the main raw materials' carbon emissions could be reduced by around 9.4%, which is equivalent to 916tons of GHG emissions per year.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF

When Robots Meet the Elderly: The Contexts of Interaction and the Role of Mediators (노인과 로봇은 어떻게 만나는가: 상호작용의 조건과 매개자의 역할)

  • Shin, Heesun;Jeon, Chihyung
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.135-179
    • /
    • 2018
  • How do robots interact with the elderly? In this paper, we analyze the contexts of interaction between robots and the elderly and the role of mediators in initiating, facilitating, and maintaining the interaction. We do not attempt to evaluate the robot's performance or measure the impact of robots on the elderly. Instead, we focus on the circumstances and contexts within which a robot is situated as it interacts with the elderly. Our premise is that the success of human-robot interaction does not depend solely on the robot's technical capability, but also on the pre-arranged settings and local contingencies at the site of interaction. We select three television shows that feature robots for the elderly and one "dementia-prevention" robot in a regional healthcare center as our sites for observing robot-elderly interaction: "Grandma's Robot"(tvN), "Co-existence Experiment''(JTBC), "Future Diary"(MBC), and the Silbot class in Suwon. By analyzing verbal and non-verbal interactions between the elderly and the robots in these programs, we point out that in most cases the robots and the elderly do not meet one-to-one; the interaction is usually mediated by an actor who is not an old person. These mediators are not temporary or secondary components in the robot-elderly interaction; they play a key role in the relationship by arranging the first meeting, triggering initial interactions, and carefully observing unfolding interactions. At critical moments, the mediators prevent the interaction from falling apart by intervening verbally or physically. Based on our observation of the robot-elderly interaction, we argue that we can better understand and evaluate the human-robot interaction in general by paying attention to the existence and role of the mediators. We suggest that researchers in human-robot interaction should expand their analytical focus from one-to-one interactions between humans and robots to human-robot-human interactions in diverse real-world situations.