• 제목/요약/키워드: Harmonics simulation

검색결과 507건 처리시간 0.021초

확률론적 방법을 이용한 교류 고속철도 시스템의 고조파 해석 (Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach)

  • 송학선;이준경;김진오;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.782-787
    • /
    • 2005
  • Magnitude of generated harmonic currents along with the operation of AC traction has nonlinear characteristics, and generated harmonic currents for high speed traction are more and more in high speed railroad(HSR) systems, especially. This paper presents probabilistic approximation method for the harmonic currents analysis about the operating speed of AC traction. To use probabilistic method for HSR system, probability density function(PDF) for collected operating speed based measure data is calculated. Mean and variance of harmonic currents of single traction are obtained based on the operating speed PDF and electrical traction model. The results of Monte Carlo Simulation(MCS) are in well accordance with the experimental and analytic methods. The harmonics of different number of trainloads are systematically investigated. It is assessed by the total demand distortion(TDD) for the HSR system.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

고주파 필터를 이용한 개선된 위상각 검출 방법 (Enhanced Phase Angle Detect Method Using High-pass Filter)

  • 허민호;송성근;김광헌;남해곤;박성준
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

MIT 요동 익형의 수치해석 (Numerical Simulation of MIT Flapping Foil Experiment)

  • 강동진;배상수
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.777-784
    • /
    • 2000
  • A Navier-Stokes code based on an unstructured finite volume method is used to simulate the MIT flapping foil experiment. A low Reynolds number ${\kappa}-{\varepsilon}$ turbulence model is used to close the Reynolds averaged Navier-Stokes equations. Computations are carried out for the whole experimental domain involving two flapping foils and a downstream hydrofoil. The computational domain is meshed with unstructured quadrilateral elements, partly structured. Numerical solutions show good agreement with experiment. The first harmonics of the velocity in the boundary layer shows local peak value inside the boundary layer and also local minimum near the edge of boundary layer. It is intensified as it develops along the blade surface. This is shown to be caused as the unsteadiness inside the boundary layer is being convected at a speed less than the free stream value. It is also shown that there is negligible mixing of the unsteadiness between the boundary layer and the free stream.

Multifunctional Uninterruptible Power Supply (UPS) System

  • Kim, Je-Hong;Choi, Yong-Joon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.813-817
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode. It is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. The system model and control algorithm are described and the system performance is verified by the simulation and experimental results.

  • PDF

계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구 (A Study on the Islanding Detection for Grid Connected Photovoltaic System)

  • 이기제;김민;이진섭;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

LINE SIDE HARMONIC ANALYSIS OF SINGLE-PHASE DIODE BRIDGE RECTIFIER WITH A DC FILTER CAPACITOR

  • Liu, Jinjun;Wang, Zhaoan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.603-608
    • /
    • 1998
  • Single-phase diode bridge rectifiers with dc filter capacitor usually operate in discontinuous mode and generate large amounts of harmonic currents. This paper presents a precise harmonic analysis of the line side current in the case that both the filter inductor and the filter capacitor are not infinite. The analytical expressions of the line side performance parameters associated with harmonics are derived. The curves that show the relationship of these parameters associated with harmonics are derived. The curves that show the relationship of these parameters as the functions of circuit parameters are illustrated. By simulation the results are verified to be accurate and the conclusion clearly reveals the relations between the line side performance parameters and circuit parameters.

  • PDF

단권변압기 탭 절환 방식에 의한 이중 접속 변형전류형 인버터의 고주파 저감 (Reduction Harmonics in Double Connected Modified Current Source Inverter by Switching Taps on Auto Transformer)

  • 이공희;한우용
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권2호
    • /
    • pp.69-76
    • /
    • 1994
  • An effective method for reducing the harmonics in double connected modified current source inverter[MCSI] by switching taps on auto transformer is presented in this paper. The proposed system operates as like a 24 step MCSI by adding only tap changing auxiliary circuit which consists of several taps and static switching elements to the 12 step multiple inverter, which is double connected three-phase six-step MCSI with an auto transformer. The basic theories of the proposed inverter systems for analyzing the output waveforms are described. And to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and the tap changing control angle of auto transformer are decided by digital simulation and its validity is verified by experiment. Although the construction of the proposed inverter is very simple, it is clarified that the output waveform of the inverter is almost the same as that of the conventional 24 step multiple inverter under the optimum condition.

  • PDF

전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

개선된 DFT를 이용한 위상 추종방법 (PLL Method Using The Improved Discrete Fourier Transform)

  • 김재형;지용혁;원충연;정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.91-93
    • /
    • 2008
  • In this paper, novel phase angle following algorithm for the single phase grid-connected inverter is proposed. Gird-connected inverter needs phase angle detection for synchronization grid voltage with the inverter output. In case of single phase grid-connected inverter, zero crossing detection and virtual 2-phase PLL using digital all pass filter or digital low pass filter are used conventionally. But these methods have a weakness for harmonics, noises and ripples. The proposed method of PLL achieve DFT(Discrete Fourier Transform) using Goertzel algorithm. It can extract fundamental voltage of grid. As a results, it can obtain phase angle using digital all pass filter without effect of harmonics, noises and ripples. Simulation results are presented to demonstrate the effectiveness of the proposed algorithm.

  • PDF