Reduction Harmonics in Double Connected Modified Current Source Inverter by Switching Taps on Auto Transformer

단권변압기 탭 절환 방식에 의한 이중 접속 변형전류형 인버터의 고주파 저감

  • 이공희 (전주공업전문대학 전기과) ;
  • 한우용 (전주공업전문대학 전기과)
  • Published : 1994.04.01

Abstract

An effective method for reducing the harmonics in double connected modified current source inverter[MCSI] by switching taps on auto transformer is presented in this paper. The proposed system operates as like a 24 step MCSI by adding only tap changing auxiliary circuit which consists of several taps and static switching elements to the 12 step multiple inverter, which is double connected three-phase six-step MCSI with an auto transformer. The basic theories of the proposed inverter systems for analyzing the output waveforms are described. And to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and the tap changing control angle of auto transformer are decided by digital simulation and its validity is verified by experiment. Although the construction of the proposed inverter is very simple, it is clarified that the output waveform of the inverter is almost the same as that of the conventional 24 step multiple inverter under the optimum condition.

Keywords