• Title/Summary/Keyword: Harmonic distortion

Search Result 734, Processing Time 0.027 seconds

ON SPIRALLIKE FUNCTIONS RELATED TO BOUNDED RADIUS ROTATION

  • Cetinkaya, Asena;Tastan, Hakan Mete
    • Honam Mathematical Journal
    • /
    • v.44 no.1
    • /
    • pp.98-109
    • /
    • 2022
  • In the present paper, we prove the growth and distortion theorems for the spirallike functions class 𝓢k(λ) related to boundary radius rotation, and by using the distortion result, we get an estimate for the Gaussian curvature of a minimal surface lifted by a harmonic function whose analytic part belongs to the class 𝓢k(λ). Moreover, we determine and draw the minimal surface corresponding to the harmonic Koebe function.

Distortion of Magnetic Field and Magnetic Force of a Brushless DC Motor due to Deformed Rubber Magnet (BLDC 모터의 고무 자석 형상 변형으로 인한 자계 변형 및 불평형 자기력 해석)

  • Lee, Chang-Jin;Jang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.834-839
    • /
    • 2007
  • This paper investigates the distortion of magnetic field of a brushless DC (BLDC) motor due to deformed rubber magnet. Global or local deformation of rubber magnet in the BLDC motor is mathematically modeled by using the Fourier series. Distorted magnetic field is calculated by using the finite element method, and unbalanced magnetic force are calculated by using the Maxwell stress tensor. The first harmonic deformation in the global deformation of rubber magnet generates the first harmonic driving frequency of the unbalanced magnetic force, and the rest harmonic deformations of rubber magnet except the harmonic deformation with multiple of common divisor of pole and slot introduces the driving frequencies with multiple of slot number ${\pm}1$ to the unbalanced magnetic force. However, the harmonic deformation with multiple of common divisor of pole and slot does not generate unbalanced magnetic force due to the rotational symmetry. When the rubber magnet is locally deformed, the unbalanced magnetic force has the first harmonic driving frequency and the driving frequencies with multiples of slot number ${\pm}1$.

  • PDF

Analysis and Design of a Passive Harmonic Filter for a Three-Phase Rectifier (3상 정류기부하에 대한 수동 고조파필터의 해석 및 설계)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.316-322
    • /
    • 2009
  • This paper presents an analytical design method of a passive harmonic filter for a three-phase diode rectifier and uses a new transfer function approach in the analysis and design. The transfer function approach derives an analytical formulation of an utility system including passive filters with a basis of Laplace transform and provides a graphical formulation so that a visualized insight into an interaction between individual filter and system response can be attainted. Harmonic impedance, voltage division and current division transfer function are used as a design tool, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. A simple five-step design procedure is introduced in the filter design, which consists of system analysis, selection of PCC(Point of Common Coupling), filter specification calculation, appropriate filter design for system and filter implementation. Philosophy governing the design procedure is based on a numerical/graphical iterative solution, trial and error with visualization feed-back based on "algebra on the graph". Finally, performance of the designed passive harmonic filter is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th harmonics are decreased within IEEE-519 distortion limits, respectively.

Harmonic Elimination Method of Using Coupling Transformer in Twelve Pulse Inverter (12 펄스 인버터에서 결합변압기를 이용한 고조파 제거기법)

  • Jeong, Chang-Yong;Lee, Young-Woon;Choi, Kyu-Hyoung;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.613-615
    • /
    • 1996
  • Harmonic elimination method of using coupling transformer in twelve pulse inverter is presented for high power application. This method is using coupling transformer and PWM(pulse width modulation) switching and voltage source inverter. The object of proposed harmonic elimination method is obtained inverter output of low THD(Total Harmonic Distortion). The simulation results confirm the proposed harmonic elimination method.

  • PDF

STARLIKENESS OF MULTIVALENT MEROMORPHIC HARMONIC FUNCTIONS

  • Murugusundaramoorthy, G.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.40 no.4
    • /
    • pp.553-564
    • /
    • 2003
  • We give sufficient coefficient conditions for starlikeness of a class of complex-valued multivalent meromorphic harmonic and orientation preserving functions in outside of the unit disc. These coefficient conditions are also shown to be necessary if the coefficients of the analytic part of the harmonic functions are positive and the coefficients of the co-analytic part of the harmonic functions are negative. We then determine the extreme points, distortion bounds, convolution and convex combination conditions for these functions.

Research on Automatic Measurement Program to shorten Test Time for FEU of HCTRS (대용량무선전송장비 전처리장치의 시험 소요시간 단축을 위한 자동 측정 프로그램 연구)

  • Shin, Suk-Ho;Cho, Tae-Chong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.45-49
    • /
    • 2020
  • FEU which is a important device in HCTRS of TICN amplifies transmission signals. Tests of intermodulation distortion and harmonic distortion for FEU have been performed manually, and take a lot of time. This paper improves the test methods using program that set up the measurement instruments and read the data automatically. This proposal allows intermodulation distortion and harmonic distortion test simultaneously. And the new test methods show that the measurement time is shorter than before. Also, it is expected that efficient quality assurance is possible because the test time can be independently managed, unlike the previous methods, where the test time was determined according to the skill level of the operator.

A Study on the Application of UPQC in AC Railway System (교류철도급전계통에 전력품질보상장치 적용에 관한 연구)

  • Choi, Joon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.220-229
    • /
    • 2004
  • The AC railway system is quite differing from the general electric power system because it is single- phase and intermittently heavy loads. Thus, inevitably power quality problems are occurred in the AC railway system, i.e. voltage regulation voltage sags, voltage imbalance, and harmonic distortion. Recently, the power quality of the AC railway system becoming a hot issue because it is affect the control and safety of high-speed traction. In addition it is also affect the power quality of the electric power system. In this paper, single-phase Unified Power Quality Conditioner(UPQS) for the AC railway system is proposed to compensate the voltage sags and harmonic distortion. The configurations and control schemes of the proposed single-phase UPQC are presented. The effectiveness of the proposed single-phase UPQC application is verified by the PSCAD/EMTDC simulation works. It can be shown that the application of UPQC in the AC railway system is very useful to compensate the voltage sags and harmonic distortion from the results of related simulation works.

Infuences of Harmonic Current on Electrical Characteristics of an Induction Motor (유도전동기의 전기적 특성에 미치는 고조파 전류의 영향)

  • Park Yang-Birm;Kim Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.67-72
    • /
    • 2005
  • This paper proposes the influences of harmonic current on electrical characteristics of an induction motor. Recently, a power system gets more worse as nonlinear load makes harmonics to affect energy lose of system and shorten lift of machines. In this paper, the electrical effect and THD(Total Harmonic Distortion) of harmonic current to an induction motor which is of great use in the industrial fields are measured and analyzed. A power conversion equipment(inverter) is installed to produce harmonics and variable reactors are installed to reduce the harmonics having an effect on the input terminal. Then the effects of the reactors are measured and analyzed. Also average voltage, current, power and 110 by harmonics are analyzed. The results show that Inn is increased by increasing load of the induction motor and installing reactors. And the harmonics affecting the input terminal are decreased by increasing reactor 3[mH] to 6[mH], however, average power of the induction motor is decreased. Therefore, it is very important that reactors should be carefully installed considering the merits and demerits resulting from the installation of reactors.

Some Properties of Harmonic Functions Defined by Convolution

  • Dixit, Kaushal Kishor;Porwal, Saurabh
    • Kyungpook Mathematical Journal
    • /
    • v.49 no.4
    • /
    • pp.751-761
    • /
    • 2009
  • In this paper, we introduce and study a comprehensive family of harmonic univalent functions which contains various well-known classes of harmonic univalent functions as well as many new ones. Also, we improve some results obtained by Frasin [3] and obtain coefficient bounds, distortion bounds and extreme points, convolution conditions and convex combination are also determined for functions in this family. It is worth mentioning that many of our results are either extensions or new approaches to those corresponding previously known results.

Robust Active LED Driver with High Power Factor and Low Total Harmonic Distortion Compatible with a Rapid-Start Ballast

  • Park, Chang-Byung;Choi, Bo-Hwan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.226-236
    • /
    • 2014
  • A new active LED driver with high power factor (PF) and low total harmonic distortion (THD) compatible with a rapid-start ballast is proposed. An LC input filter is attached to the ballast to increase PF and reduce THD. A boost converter is then installed to regulate the LED current, where an unstable operating region has been newly identified. The unstable region is successfully stabilized by feedback control with two zeroes. The extremely high overall system of the 10th order is completely analyzed by the newly introduced phasor transformed circuits in static and dynamic analyses. Although a small DC capacitor is utilized, the flicker percentage of the LED is drastically mitigated to 1% by the fast controller. The proposed LED driver that employs a simple controller with a start-up circuit is verified by extensive experiments whose results are in good agreement with the design.