A Study on the Application of UPQC in AC Railway System  

Choi, Joon-Ho (전남대학교 전기공학과)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.18, no.6, 2004 , pp. 220-229 More about this Journal
Abstract
The AC railway system is quite differing from the general electric power system because it is single- phase and intermittently heavy loads. Thus, inevitably power quality problems are occurred in the AC railway system, i.e. voltage regulation voltage sags, voltage imbalance, and harmonic distortion. Recently, the power quality of the AC railway system becoming a hot issue because it is affect the control and safety of high-speed traction. In addition it is also affect the power quality of the electric power system. In this paper, single-phase Unified Power Quality Conditioner(UPQS) for the AC railway system is proposed to compensate the voltage sags and harmonic distortion. The configurations and control schemes of the proposed single-phase UPQC are presented. The effectiveness of the proposed single-phase UPQC application is verified by the PSCAD/EMTDC simulation works. It can be shown that the application of UPQC in the AC railway system is very useful to compensate the voltage sags and harmonic distortion from the results of related simulation works.
Keywords
AC railway system; high-speed traction; power quality; AT(auto transferrer); UPQC(unified power quality conditioner); voltage sag; harmonic distortion; PSCAD/EMTDC;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 H. Akagi, Y. Kanazawa, and A. Nabae, 'Instantaneous reactive power compensators comprising switching devices without energy storage components', IEEE Transaction on IA, Vol. IA-20, No.3, pp. 625-630, May/June 1984
2 M. Aredes, K. Heumann, and E.H. Watanabe, 'An Universal active power line conditioner', IEEE Transaction on Power Delivery, Vol. 13, No.2, pp. 545-551, Apr. 1988
3 추동욱, 김재철, 전용주, 임성정, 김태수, '교류 전기의 AT 급전계통 내 다수열차 운행 모의알고리즘연구', 대한전기학회논문지, Vol.50, No.2, 2001년 6월
4 Baichao Chen and Kokemak, J.M, 'Thyristor controlled two-stage magnetic-valve reactor for dynamic VAr-compensation in electric railway power supply systems', IEEE Fifteenth Annual APEC, Vol. 2, pp. 1066-1072, 2000   DOI
5 Ando, M, et aI., 'Development of railway static power conditioner used at substation for Shinkanse', Proceedings of the Power Conversion Conference, Vol. 3, pp. 1108-1111, 2002
6 Watanabe, T., 'Trend of railway technologies and power semiconductor devices', Proceedings. of The 11th International Symposium on ISPSD 1999, pp. 11-18, 1999
7 김재철 외, '교류급전시스템 고장해석 및 철도배전계통 보호시스템 체계화', 숭실대학교 생사기술연구소, 2002년 3월
8 Tsai-Hsiang Chen and Yen-feng Hsu, 'Systematized short- circuit analysis of a 2x25 kV electric traction network', Electric Power Systems Research, Vol. 47, No. 2, pp. 133-142, 15. October. 1998   DOI   ScienceOn
9 Hackwell, D., et aI., 'The use of static shunt compensation to upgrade existing electrified raiIway', International Conference on Main Line Railway Electrification, pp. 232-235, Sep. 1989
10 Hasuike, K., et aI., 'Static power conditioner using GTO converters for AC electric railway', Power Conversion Conference 1993, pp. 641-646, Apr. 1993
11 Baba, K., et. aI., 'Control methods and characteristics of power converter with large capacity for electric raiIway system', Power Conversion Conference 2002, Vol. 3, pp. 1039-1044, 2002
12 Eguchi, N., et. aI., 'Self-conmutated SVC for electric raiIway', International Conference on Power Electronics and Drive Systems, Vol. 2, pp.732-737, Feb. 1995
13 Hase, S.-I., et. aI., 'Compensation of voltage drop using static VAr compensator at sectioning post in AC electric raiIway system', Power Conversion Conference 1997, Vol. 2, pp. 955-960, Aug. 1997   DOI
14 최준호, 김태수, 김재철, 문승일, 남해곤, 정일엽, 박성우, '전기철도계통에 순간전압강하 보상장치 적용에 관한 연구', 한국조명전기설비학회논문지, Vol. 17, No.6, pp. 95-104, 2003년 11월   DOI