• Title/Summary/Keyword: HEALTHCARE

Search Result 7,116, Processing Time 0.047 seconds

When Robots Meet the Elderly: The Contexts of Interaction and the Role of Mediators (노인과 로봇은 어떻게 만나는가: 상호작용의 조건과 매개자의 역할)

  • Shin, Heesun;Jeon, Chihyung
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.135-179
    • /
    • 2018
  • How do robots interact with the elderly? In this paper, we analyze the contexts of interaction between robots and the elderly and the role of mediators in initiating, facilitating, and maintaining the interaction. We do not attempt to evaluate the robot's performance or measure the impact of robots on the elderly. Instead, we focus on the circumstances and contexts within which a robot is situated as it interacts with the elderly. Our premise is that the success of human-robot interaction does not depend solely on the robot's technical capability, but also on the pre-arranged settings and local contingencies at the site of interaction. We select three television shows that feature robots for the elderly and one "dementia-prevention" robot in a regional healthcare center as our sites for observing robot-elderly interaction: "Grandma's Robot"(tvN), "Co-existence Experiment''(JTBC), "Future Diary"(MBC), and the Silbot class in Suwon. By analyzing verbal and non-verbal interactions between the elderly and the robots in these programs, we point out that in most cases the robots and the elderly do not meet one-to-one; the interaction is usually mediated by an actor who is not an old person. These mediators are not temporary or secondary components in the robot-elderly interaction; they play a key role in the relationship by arranging the first meeting, triggering initial interactions, and carefully observing unfolding interactions. At critical moments, the mediators prevent the interaction from falling apart by intervening verbally or physically. Based on our observation of the robot-elderly interaction, we argue that we can better understand and evaluate the human-robot interaction in general by paying attention to the existence and role of the mediators. We suggest that researchers in human-robot interaction should expand their analytical focus from one-to-one interactions between humans and robots to human-robot-human interactions in diverse real-world situations.

A Study of Family Caregiver's Burden for the Terminally III Patients (지역사회 말기질환자 가족 부담감에 관한 연구)

  • Han, Sung-Suk;Ro, You-Ja;Yang, Soo;Yoo, Yang-Sook;Kim, Sek-Il;Hwang, Hee-Hyung
    • Journal of Home Health Care Nursing
    • /
    • v.10 no.1
    • /
    • pp.58-72
    • /
    • 2003
  • The purpose of this study was to describe the perceived burden of the terminally III patients's caregiver and to analyze relationship between the perceived burden and the various demographics, illness characteristics, family relationships, and economic factor of the family & patients. The sample of 132 caregivers who care for the terminally III patients Kyung-Gi province, Seoul, Korea. The period of this study was from August to September, 2002. The perceived burden of the family caregiver was measured by the burden scale(20 items, 4 point scale) developed by Montgomery et al. (1985). The Data was analyzed using SAS-program by t-test and ANOVA. The results were as follows; 1. The mean of the family caregiver's burden score was 3.02. The score showed that caregivers perceive severe the level of burden. The hight items of the family caregiver's burden were' I feel it is painful to watch patient's diseases'(3.77). 'I feel afraid for what the future holds for my patients'(3.66), 'I feel it reduced to amount of privacy time'(3.64). 2. The caregiver's burden was significantly related to patient's gender(F=3.17, p= 0.0020), patient's job(F=2.49, p=0.0476), caregiver's age(F=4.29, p=0.0030), and caregiver's job(F=2.49, p=0.0476). 3. The caregiver's burden according to illness characteristics showed no significant difference. 4. The caregiver's burden was significantly associated with patient's family relationship (F=4.05, p=0.0041), patient's care mean period in a day(F=47.18,

  • PDF

Mushroom consumption patterns in the capital area (수도권 도시가구의 버섯 소비양상)

  • Lee, Yun-Hae;Jeong, Gu-Hyoen;Kim, Yeon-Jin;Chi, Jeong-Hyun;Lee, Hae-Kil
    • Journal of Mushroom
    • /
    • v.15 no.1
    • /
    • pp.45-53
    • /
    • 2017
  • Profitability of farmers has decreased mainly owing to low price while the gross amount of mushroom production has increased continuously in South Korea. In this regard, analyzing patterns of mushroom consumption is believed to be meaningful. We used a panel data set consisting of 667 families, from 2010 to 2015. Based on the panel data, mushroom consumption patterns of people living in city areas were examined. Multiple descriptive analysis methods and frequency analysis approaches were adopted in this study in terms of time and space dimensions, demographic properties, and purchase behaviors. The findings of this studyshow that mushroom purchase is highly dependent on seasonal events, which implies that the product consumption timing is predictable. In addition, yearly purchase amount patterns reflect that superstores have become the major mushroomtrading venues. This directly supports the need to establish supply chain capabilities for mushroom farmers so that they gain more bargaining power against enterprise-type groceries. Finally, functional features of mushroom can be linked with marketing promotion because purchase patterns demonstrate potential needs for healthcare food in mushroom categories. Based on the analyzed patterns, this paper provides insightful implications for policy makers who want to promote mushroom consumption.

Guideline for Imaging Dose on Image-Guided Radiation Therapy (영상유도방사선치료에 있어 영상선량 가이드라인)

  • Cho, Byung Chul;Huh, Hyun Do;Kim, Jin Sung;Choi, Jin Ho;Kim, Seong Hoon;Cho, Kwang Hwan;Cho, Sam Ju;Min, Chul Kee;Shin, Dong Oh;Lee, Sang Hoon;Park, Dong Wook;Kim, Kum Bae;Choi, Sang Hyoun;Kim, Hye Young;Ahn, Woo-Sang;Kim, Tae Hyeong;Han, Su Cheol
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.1-24
    • /
    • 2013
  • As image-guided radiation therapy (IGRT) has been commonly used for more accurate patient setup and monitoring tumor movement during radiation therapy, the necessity for management of imaging dose is increased. However, it has not been an interest issue to radiation therapy communities because the imaging dose is much lower than the therapeutic dose. However, since the cumulative dose from 4DCT and repeated imaging for daily setup verificationin would not be ignorable, appropriate dose management based on ALARA (As Low As Reasonably Achievable) principle is required. In this study, we aimed that (1) survey on imaging equipments and modalities used for IGRT, (2) estimation of IGRT imaging dose depending on treatment types and equipments, (3) collecting data of effective dose on treatment sites from each equipment and imaging protocol, and thus finally provide guideline for imaging dose reduction and optimization.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Usefulness of Permeability Map by Perfusion MRI of Brain Tumor the Grade Assessment (뇌종양의 등급분류를 위한 관류 자기공명영상을 이용한 투과성영상(Permeability Map)의 유용성 평가)

  • Bae, Sung-Jin;Lee, Joo-Young;Chang, Hyuk-Won
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.325-334
    • /
    • 2009
  • Purpose : This study was conducted to assess how effective the permeability ratio and relative cerebral blood volume ratio are to tumor through perfusion MRI by measuring and reflecting the grade assessment and differential diagnosis and the permeability and relative cerebral blood volume of contrast media plunged from blood vessel into organ due to breakdown of blood-brain barrier in cerebral. Subject and Method : Subject of study was 29 patients whose diagnosis were confirmed by biopsy after surgery and 550 (11 slice$\times$50 image) perfusion MRI were used to make image of relative cerebral blood volume with the program furnished on instrument. The other method was to transmit to private computer and the image analysis was made additionally by making image of relative cerebral blood volume-reformulated singular value decomposition, rCBV-rSVD and permeability using IDL.6.2. In addition, Kruskal-wallis test tonggyein non numerical average by a comparative analysis of brain tumors Results : The rCBV ratio (Functool PF; GE Medical Systems and IDL 6.2 program by analysis) and permeability ratio of tumors were as follows; high grade glioma(n=4), (14.75, 19.25) 13.13. low grade astrocytoma(n=5) (14.80, 15.90) 11.60, glioblastoma(n=5) (10.90, 18.60), 22.00, metastasis(n=6) (11.00, 15.08). 22.33. meningioma(n=6) (18.58, 7.67), 5.58. oliogodendroglioma(n=3) (23.33, 16.33, 15.67. Conclusion : It was not easy to classify the grade with the relative cerebral blood volume ratio measured by using the relative cerebral blood image by type of tumors, however, permeability ratio measured by permeability image revealed that the higher the grade of tumor, the higher the measured permeability ratio, showing the assessment of tumor grade is more effective to differential diagnosis.

  • PDF

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Utility of Water Intake to Reduce Stomach's Additional Shooting in PET/CT Test (PET/CT 검사에서 Stomach의 추가 촬영을 줄이기 위한 수분 섭취의 유용성)

  • Lee, Seung-Hwan;Bae, Seong-Bok;Jeong, Byeong-Gon;Lee, Gyu-Chan;Lee, Gwang-Cheol;Bae, Won-Gyu
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.81-85
    • /
    • 2011
  • Purpose: With the introduction of PET since 1994, test methods have made rapid progress. Accordingly, the studies on the diagnosis and treatment of cancer as well as treatment response evaluation PET test are useful. However, it is difficult to divide stomach lesions and secretion. The purpose of this study is to reduce additional shooting by dividing lesions and secretion of stomach. Materials and Method: This study aiming at total 228 cancer patients was conducted from Aug 18 to Sep. 10, 2010. Among them, 115 patients had a test without water intake before shooting from Aug. 8 to 31 and 113 had a test after drinking 500 cc water right before shooting from Sep. 1 to 10 The Discovery ST PET/CT (GE Healthcare, USA) was used, and pearson's chi-square test was conducted to analyze significance through SPSS (Ver.18). Results: Among the total 228 cancer patients, there were 115 who had a test without water intake before shooting, 89 who had no double additional shooting, 13 who had stomach additional shooting and 13 who had other additional shooting. In addition, 109 had no additional shooting among 113 who had a test after taking 500 cc water, 1 had stomach additional shooting and 3 had other additional shooting. According to the findings above, the patients who had a test without water intake show reduced additional shooting, but for more exact significance, pearson's Chi-square test was carried out and the significance percentage was 0.001 that is smaller than 0.05, which means two groups have a significant relationship. As the minimum expectation frequency was 6.94 and there was no expectation frequency smaller than 5, so that it doesn't need to carry out pearson's exact verification. Conclusion: The above analysis has found that if one drinks 500cc water before the test, not only stomach additional shooting but also other additional shooting can be dramatically reduced, and test delay can be also reduced.

  • PDF

Public Perception and Acceptance of the National Strategy for Well-Dying (웰다잉 국가 전략에 대한 일반 국민들의 인식 및 수용도)

  • Lee, Seo Hyun;Shin, Dong Eun;Sim, Jin Ah;Yun, Young Ho
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2013
  • Purpose: Ten years have passed since the Korean government announced its plan to institutionally support hospice and palliative care in 2002. In line with that, this study aims to suggest future directions for Korea's hospice and palliative care policy. Methods: We conducted a survey on people's perception and acceptance of well-dying. Data were collected from 1,000 participants aged 19~69 years between June 1 and June 11, 2012 via computer-assisted telephone interviews. Results: The most important factor for well-dying was placing no burden of care on others (36.7%) and the second most important factor was staying with their family and loved ones (19.1%). Among nine suggestions of policy support for well-dying, the most popular was the promotion of voluntary care sharing (88.3%), followed by the palliative care training support for healthcare providers (83.7%) and the support for palliative care facilities instead of funeral halls (81.7%). The idea of formulating a five-year national plan for end-of-life care drew strong support (91%). According to the survey, the plan should be implemented by the central government (47.5%), the National Assembly (20.2%) or civic groups (10%). Conclusion: This study demonstrated the public consensus and their consistent direction toward policy support for well-dying. Results of this study may serve as a foundation for the establishment of policy support for people's well-dying and palliative care at the national-level.