• Title/Summary/Keyword: Green Building Evaluation System

Search Result 114, Processing Time 0.024 seconds

Comparison Study of Air-conditioning Systems using LCC Analysis (LCC를 이용한 공조 방식별 비교 연구)

  • Kim, Joung-Kuk;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

An Analysis and Evaluation of Urban Landscapes Using Images Taken with a Fish-eye Lens (천공사진(天空寫眞)을 이용한 도시경관의 분석 및 평가)

  • Han Gab-Soo;Yoon Young-Hwal;Jo Hyun-Kil
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.11-21
    • /
    • 2005
  • The purpose of this study was to analyze and evaluate landscape characteristics by classification of landscapes in Chuncheon. A system was developed to convert images taken with a fish-eye lens to panoramic pictures. Landscape characteristics were analyzed by appearance rate and area distribution rate of landscape elements on panorama picture. Landscape characteristics were analyzed according to the number of times landscape elements appeared and the amount of area that each element occupied in the panoramic picture. Each panoramic picture was classified into five types based on these landscape element factors. Landscape evaluation was carried out using dynamic images converted from picture by fish-eye lens. The results of this study can be summarized as follows. The urban landscape can be characterized by four essential factors: interconnectedness, nature, urban centrality and landscape scale. Five types of landscapes were determined: detached residential building landscape (type 1), street landscape with various elements (type 2), street landscape in the center of a city (type 3), landscape of housing complex (type 4), and landscape of green space (type 5). Type 5 had the highest degree of landscape satisfaction and the landscape satisfaction increased with the number of appearances of natural elements. The amount of peen space had a high relation with a landscape satisfaction.

A Case Study on the UK Park and Green Space Policies for Inclusive Urban Regeneration (영국의 포용적 도시재생을 위한 공원녹지 정책 사례 연구)

  • Kim, Jung-Hwa;Kim, Yong-Gook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.5
    • /
    • pp.78-90
    • /
    • 2019
  • The purpose of this study is to explore the direction of developing policies for parks and green spaces for inclusive urban planning and regeneration. By reviewing the status, budget, and laws pertaining to urban parks in Korea, as well as assessing the inclusivity of urban parks, this study revealed the problems and limitations in Korea as follows. First, the urban park system, which takes into account indicators such as park area per capita and green space ratio, is focused only on quantitative expansion. Second, the distribution of urban parks is unequal; hence, the higher the number of vulnerable residents, the lower the quality of urban parks and green spaces. Moreover, this study focused on the UK central government, along with the five local governments, including London, Edinburgh, Cardiff, Belfast, and Liverpool. Through an analysis of the contexts and contents establishing UK park and green space policies that can reduce socioeconomic inequalities while at the same time increase inclusiveness. This study discovered the following. The government's awareness of the necessity of tackling socioeconomic inequalities to make an inclusive society, the change in the urban regeneration policies from physical redevelopment to neighborhood renewal, and the survey and research on the correlation of parks and green spaces, inequality, health, and well-being provided the background for policy establishment. As a result, the creation of an inclusive society has been reflected in the stated goals of the UK's national plan and the strategies for park and green space supply and qualitative improvement. Deprived areas and vulnerable groups have been included in many local governments' park and green space policies. Also, tools for analyzing deficiencies in parks and methods for examining the qualitative evaluation of parks were developed. Besides, for the sustainability of each project, various funding programs have been set up, such as raising funds and fund-matching schemes. Different ways of supporting partnerships have been arranged, such as the establishment of collaborative bodies for government organizations, allowing for the participation of private organizations. The study results suggested five policy schemes, including conducting research on inequality and inclusiveness for parks and green spaces, developing strategies for improving the quality of park services, identifying tools for analyzing policy areas, developing park project models for urban regeneration, and building partnerships and establishing support systems.

Change Soil Water and Evaluation with Respect to Shallow-Extensive Green Roof System (저토심 옥상녹화시스템에 따른 토양수분의 변화)

  • Park, Jun-Suk;Park, Je-Hea;Ju, Jin-Hee;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.843-848
    • /
    • 2010
  • This study focused on the characteristics of change soil water with respect to soil thickness and soil mixture ratio, in order to effectively carry out an afforestation system for a roof with a low level of management and a light weight. Soil hardness tended to increase as sand particle was increase regardless soil thickness and soil porosity had more higher artificial soil than natural soil mixture. In case of soil pH, natural soil mixture had between 6.7 and 7.4, and artificial soil mixture had 6.0~6.8. Organic matter, electrical conductance and exchangeable content were highest in $L_{10}$, which it had the highest leafmold ratio. Soil moisture tension(kPa) in 15cm soil thickness was observed natural soil mixture had a considerable change but artificial soil mixture had a gradual change when non-rainfall kept on. In the experimental $L_{10}$, $S_{10}$, $S_7L_3$ and $S_5L_5$ object, the amount of moisture tended to rapidly decrease. However, in the experimental $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$ objects, which contained pearlite and peat moss, the amount of moisture tended to gradually decrease. As a result, the use of a artificial soil mixture soil seems to be required for the afforestation of a roof for a low level of management.

Analysis of Microclimate Impact According to Development Scenarios of Vacant Land in Downtown Seoul - A Comparison of Wind Speed and Air Temperature - (서울 도심 공지의 개발 시나리오에 따른 미기후 영향 분석 - 풍속 및 기온 비교 -)

  • Baek, Jiwon;Park, Chan;Park, Somin;Choi, Jaeyeon;Song, Wonkyong;Kang, Dain;Kim, Suryeon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.2
    • /
    • pp.105-116
    • /
    • 2021
  • In the city of high population density crowded with buildings, Urban Heat Island (UHI) is intensified, and the city is vulnerable to thermal comfort. The maintenance of vacant land in downtown is treated as a factor that undermines the residential environment, spoils the urban landscape, and decreases the economic vitality of the whole region. Therefore, this study compared the effects on microclimate in the surrounding area according to the development scenarios targeting the vacant land in Songhyeon-dong, Jongno-gu, Seoul. The status quo, green oriented, building oriented and green-building mediation scenarios were established and ENVI-met was used to compare and analyze the impact of changes in wind speed, air temperature and mean radiant temperature (MRT) within 1 km of the target and the target site. The result of inside and 1 km radius the targeted area showed that the seasonal average temperature decreased and the wind speed increased when the green oriented scenario was compared with the current state one. It was expected that the temperature lowered to -0.73 ℃ or increased to 1.5 ℃ in summer, and the wind speed was affected up to 210 meters depending on the scenario. And it was revealed that green area inside the site generally affects inside area, but the layout and size of the buildings affect either internal and external area. This study is expected to help as a decision-making support tool for developing Songhyeon-dong area and to be used to reflect the part related to microclimate on the future environmental effects evaluation system.

The Evaluation of GHG Emissions in Railroad Construction Sector (철도건설의 온실가스 배출량 산정평가)

  • Lee, Jae-Young;Jung, Woo-Sung;Hwang, In-Hwan;Kim, Yong-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.3
    • /
    • pp.271-275
    • /
    • 2011
  • According to governmental policies for green growth, the increase in the traffic volume of railroad is a representative method to reduce total greenhouse gas (GHG) emitted from transport. Comprehensive assessment for the GHG emission of railroad has been studied to compare the difference of transport modes just in the operating step excluded the construction step. The purpose of this study was to evaluate GHG emissions in railroad construction sector. The targets were some construction works for civil, track, building, and electric system in A line. The GHG emission source of constructing railroad infrastructure was mainly the energy consumption of heavy equipments. As a result, the civil construction sector showed more than 96% of total GHG emissions and its specific GHG emission was 2.191 ton $CO_2e/m$. Also, the specific GHG emissions of civil construction works were of the order: earthworks > tunnels > bridges > station. In future, it will be required to calculate the overall GHG emission of railroad through life cycle approaches including operation, maintenance and disposal step.

The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test (가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구)

  • Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

A Study on the Policy Direction of Space Composition of the Future School in Old High School - Focused on The Judgment of Space Relocation for the Application of the High School Credit System - (노후고등학교의 미래학교 공간구성 정책방향에 관한 연구 - 고교학점제 적용을 위한 공간 재배치 판단을 중심으로 -)

  • Lee, Jae-Lim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.21 no.3
    • /
    • pp.1-13
    • /
    • 2022
  • This study is a case study to identify the spatial composition and structural problems of existing schools for spatial innovation as a future school that can operate a credit system for old high schools and establish a mid-to-long-term arrangement plan as a credit system operating school capable of various teaching and learning in the future. The study results are as follows: First, most of the problems of the old high schools entailed that there was very poor connectivity between buildings as most of them were arranged in a single, standard design-type unit building and distributed in multiple buildings. In addition, the floor plan of each building is suggested to be a structure in which student exchange and rest functions cannot be achieved during the break period due to the spatial composition of the classroom and hallway concepts. Second, in the direction of the high school space configuration for future school space innovation, the arrangement plan should be established by reflecting the collective arrangement in consideration of the shortening of the movement route and the expansion of subject areas due to the movement of students on the premise of the subject classroom system. Moreover, it is desirable to provide a square-type space for rest and exchange in the central area where communication and exchange are possible according to the moving class. Third, as the evaluation criteria for relocating old high schools, a space program is prepared based on the number of classes in the future, and legal analysis of school land use and land use efficiency analysis considering regional characteristics are conducted. Based on such analysis data, mid-to-long-term land use plans and space arrangement plans for the entire school space such as the school facility complex are established.