• 제목/요약/키워드: General connection

검색결과 664건 처리시간 0.026초

내·외부고객의 병원선택요인이 병원이미지에 미치는 영향 (The Impact of Hospital Selection Factors between Internal and External Customers on Hospital Image)

  • 이현숙
    • 보건행정학회지
    • /
    • 제23권3호
    • /
    • pp.281-288
    • /
    • 2013
  • Background: The purpose of this study is to grasp the factors forming hospital image and to measure evaluation of internal and external customers towards hospital choice factors. Methods: This study is based 4 types of choice factor such as physical, human, accessibility, and connection. Data were assessed using 98 patients and 96 internal employees who work at A general hospital in Seoul and 116 patients and 97 internal employees at B general hospital in Chunkcheongbuk-do. Data were collected with self-administered questionnaires from February 17 to April 29 in 2012 and analyzed SPSS ver. 18.0 by using frequency, t-test, analysis of variance, correlation, and multiple regression. Results: The results of this study show that factors affecting hospital image is significant different between internal and external customers of hospital A and B. Expecially the finding of this study will be applied to improve connection factors in administrative department of hospital for hospital image. Conclusion: This study presents primary data for correct decision making to authorities of local hospitals that have concern about marketing strategy for hospital image.

Line Balancing을 위한 최적 Cycle Time의 결정방법 (A Study on the Determination of Optimum Cycle Time for Assembly Line Balancing)

  • 이근부
    • 산업경영시스템학회지
    • /
    • 제3권3호
    • /
    • pp.35-39
    • /
    • 1980
  • Although the product line produces a large volume of goods in a relatively short time, once the product line is established there are numerous problems that arise in connection with this product line. One of these problems is the problem of balancing operations or stations in terms of equal times and in terms of the times required to meet the desered rate of production. The objective of line balancing is minimizing the idle time on the line for all combinations of work stations subject to certain restrictions. In general, there are two types of line-balancing situations : (1) assembly line balancing and (2) fabrication line balancing. Two approaches to the assembly line balancing problem have been used. The first assumes a filed cycle time and find the optimum number of work stations. The second approach to the assembly line balancing problem assumes the number of work stations to be fixed and systematically coverages on a solution which minimizes the total delay time by minimizing the cycle time. Here the cycle time is determined by the longest station time. In this paper, by using the second approach method, a general mathematical model, problem solutions, and computer program for the assembly line balancing problem is presented. Data used is obtained from the company which has been confronted with many problems arising in connection with their assembly line.

  • PDF

GPRS/UMTS의 Core Network에서 SVC holding time 제어기법 (The Control Mechanism on SVC holding time of Core Network in GPRS/ UMTS Network)

  • 곽용원;박웅;정영식;민재홍
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.648-652
    • /
    • 2003
  • 제 3세대 이동 통신망인 GPRS(General Packet Radio Service)망에서는 SGSN(Serving GPRS Support Node)과 GGSN(Gateway GPRS Support Node) 사이의 전송계층을 IP-Over-ATM 망을 기반으로 한다. 이는 비연결형(connectionless) IP 트래픽들을 연결지향형(connection-oriented) ATM 전송계층을 통해 전송하는 것을 의미한다. 이때 효율적인 자원관리를 위해 적절한 VC(Virtual Circuit)의 접속과 해제를 수행해야 한다. 본 논문에서는 GPRS망에 인터넷 웹 서비스 트래픽 모델을 다양한 VC holding Cost Pricing Model(LRU, Mean-Variance, Adaptive policy[2])에 적용하였다. 각각의 기법들에서 VC의 이용율(utilization)과 설정율(setup rate)을 분석함으로써 각 기법의 성능을 비교하였다.

  • PDF

CFT 기둥-RC 무량판 슬래브 외부접합부의 횡저항 성능 (Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Exterior Connections)

  • 송호범;송진규;오상원;김병조
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.61-64
    • /
    • 2008
  • 콘크리트충전 강관기둥(Concrete Filled steel Tube Column)과 RC 무량판 슬래브의 조합은 거푸집을 사용하지 않는다는 것만으로도 초고층 건물의 공기단축에 상당한 영향을 미칠 수 있다. 뿐만 아니라 기둥의 내력 증진으로 인한 기둥 크기의 축소, 그로 인한 공간 활용도의 증가, 층간 소음문제 해결 등 많은 장점이 잠재되어 있다. 하지만 접합부의 성능을 정확히 밝혀내는 것이 우선 이루어져야 하며, 본 논문에서는 기존에 수행된 CFT 기둥-RC 무량판 슬래브의 내부접합부에 대한 중력 실험과 횡하중 실험을 바탕으로 외부접합부에 대한 실물대 실험을 수행하였다. 외부접합부 실험 결과, 내부접합부 실험체에 비하여 동일한 조건에서 설계된 외부접합부 실험체는 최대 모멘트강도가 $50%{\sim}65%$ 감소하였고, 내진밴드가 추가된 CFT-E2 실험체는 BME 실험체에 비하여 20%의 최대모멘트 증진과 탁월한 연성능력, 에너지 흡수능력을 보유한 것으로 나타났다. 또한 CFT-E2는 내진밴드의 사용으로 슬래브의 휨거동 영역이 확장되었으며 모든 실험체가 설계기준에서 요구하는 0.4V$_c$중력하중 하에서 1.5% 횡변 위비를 만족하였다.

  • PDF

전통 민도리식 목구조 화통맞춤의 구조적 특성 (A Structural Characteristics of Hwatong-Connections in Traditional Mindori Type of Wood Structures)

  • 유혜란;권기혁
    • 건축역사연구
    • /
    • 제21권3호
    • /
    • pp.7-28
    • /
    • 2012
  • This study is intended to Mindori structure which is general private houses' structural type among traditional types and is a basic study to confirm structural characteristics of Hwatong connection which is general connection type of column-beam-cross beam. It is aimed to analyze how main member, column, such as size, figure, thickness of Sungetuk and Dugeup affect on structure. Following conclusions are drawn. 1. According to connection conditions, models with big coefficient of friction show stable hysteretic behavior until the angle rotation of member reaches 1/60 and models with small coefficient of friction show dramatical increase in load after the angle rotation of member reaches 1/24. After the angle rotation of member reaches 1/30, separation distance of members is identified physically and cracks are not observed. 2. Specimens with big coefficient of friction show similar inner force regardless of column size(except column size 150mm) and models with small coefficient of friction show increasing inner force as the column size increases. Specimens with same sectional area have similar inner force even though the column figures are different. The thickness of Sungetuk and Dugeup doesn't affect inner force greatly, however, when the thickness of Sungetuk is thin, it could lead to failure of structure as it breaks. 3. The bigger the size of column and the coefficient of friction are, the smaller Bending stiffness depreciation ratio is. 4. Energy Dissipation Efficiency differs from the coefficient of friction. When the coefficient of friction is big, square column shows bigger than round one and it is bigger when the thickness of Sungetuk and Dugeup is thicker. When the coefficient of friction is small, round column shows bigger than square one.

CFT 기둥 - RC 무량판 슬래브 접합부의 횡저항 성능 (Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Connections)

  • 송진규;송호범;오상원;이철호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.65-68
    • /
    • 2008
  • RC 무량판 구조시스템은 여러 구조적 장점들로 인해 그 사용이 증가하는 추세이지만 횡방향 변위성능, 변형성능에 대한 약점을 지니고 있고, 고층화에 따라 기둥 크기가 증가하는 단점을 가지고 있다. 이러한 구조적 단점들은 CFT기둥의 사용을 통해 어느 정도 보완될 수 있으나 현재 CFT 기둥과 RC 무량판 접합부의 상세 및 설계법은 명확하게 제시된 바가 없다. 따라서 본 논문은 실물대 실험을 통해 일반 RC 기둥-무량판 접합부와 비교하여 CFT 기둥-RC 무량판 접합부의 횡저항 성능을 검증하고, 횡하중-변위비 성능에 따른 접합부의 모멘트 성능과 연성 능력을 파악하였다. 각기 다른 변수를 지닌 4개의 실험체를 제작하여 횡력 실험을 수행한 결과 다음과 같은 결론을 도출하였다. CFT 실험체는 전단머리의 영향으로 위험단면이 확장되었으며 일반 RC 기둥 실험체에 비해 초기강성은 35%, 모멘트는 25${\sim}$35% 증가하였고, 모멘트의 증가로 인한 에너지 흡수율이 증가하였다. 모든 실험체는 슬래브의 전단거동이 지배하였지만 내진밴드로 보강된 CFT 실험체는 슬래브의 휨거동 영역이 확장되었고, 연성비와 에너지 흡수율 또한 증가하였다.

  • PDF

혼합구조의 성능 향상을 위한 개선된 접합방식의 개발 (I) : 개선된 접합방식을 도출하기 위한 3차원 비선형 해석 (Developments of Advanced Connection Type for Improvements of Mixed Structures(I) : 3D Nonlinear Analysis of the Various Connection Types for Deriving Advanced Connection Type)

  • 윤익중;허택녕;김문겸;조성용
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.89-94
    • /
    • 2008
  • 서로 다른 부재로 이루어진 혼합구조물은 불연속면인 접합부에 강도저감, 응력집중이 발생하거나 응력전달이 확실하지 않게 되므로 접합부에 대한 연구는 이미 오래전부터 다양한 방법을 통하여 연구되어 왔다. 특히 최근에 장대교량에 혼합구조를 적용하면, 경제성과 시공성이 확보되고 구조적 성능이 증가하는 것으로 알려지면서 일본, 유럽 등과 같은 선진국에서 혼합구조의 연구 및 시공이 활발히 이루어지고 있는 실정이다. 하지만 이에 대한 국내의 연구는 상대적으로 미미한 수준에 있다. 따라서 본 논문에서는 전술한 혼합구조의 접합부가 구조물 전체에 미치는 영향을 분석하기 위하여 기존에 수행된 많은 연구결과를 검토하고, 현재 가장 널리 사용되고 있는 전후면판 방식의 접합부를 갖는 혼합구조의 비선형 해석을 수행하여 그 장단점을 파악하였다. 또한, 이를 기초로 혼합구조 접합부의 성능을 개선할 수 있는 접합부 방식를 제안하고, 이를 기존의 방식과 비교분석하기 위하여 객관적인 6개의 기준을 설정하여 분석하였다. 개선된 모형으로는 형태를 개선안 모형 2개와 불연속면을 보강한 모형 1개 총 3개의 개선모형를 설정하였으며, 객관적인 비교기준으로 하중-처짐관계, 처짐곡선분포, 개구폭, 스터드축력, 소성변형 크기 및 위치, 접합부 응력분포 등을 설정하였다. 이와 같은 기준에 따라 기존 접합부 방식과 개선된 방식을 서로 비교검토한 결과, 본 논문에서 제안한 접합부 방식이 구조물의 성능개선에 큰 효과가 있는 것으로 나타났으므로 혼합구조의 새로운 접합부 방식으로 제안하였다.

The effect of RBS connection on energy absorption in tall buildings with braced tube frame system

  • Shariati, Mahdi;Ghorbani, Mostafa;Naghipour, Morteza;Alinejad, Nasrollah;Toghroli, Ali
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.393-407
    • /
    • 2020
  • The braced tube frame system, a combination of perimeter frame and bracing frame, is one of the systems used in tall buildings. Due to the implementation of this system in tall buildings and the high rigidity resulting from the use of general bracing, providing proper ductility while maintaining the strength of the structure when exposing to lateral forces is essential. Also, the high stress at the connection of the beam to the column may cause a sudden failure in the region before reaching the required ductility. The use of Reduced Beam Section connection (RBS connection) by focusing stress in a region away from beam to column connection is a suitable solution to the problem. Because of the fact that RBS connections are usually used in moment frames and not tested in tall buildings with braced tube frames, they should be investigated. Therefore, in this research, three tall buildings in height ranges of 20, 25 and 30 floors were modeled and designed by SAP2000 software, and then a frame in each building was modeled in PERFORM-3D software under two RBS-free system and RBS-based system. Nonlinear time history dynamic analysis is used for each frame under Manjil, Tabas and Northridge excitations. The results of the Comparison between RBS-free and RBS-based systems show that the RBS connections increased the absorbed energy level by reducing the stiffness and increasing the ductility in the beams and structural system. Also, by increasing the involvement of the beams in absorbing energy, the columns and braces absorb less energy.

종단간 네트워크 시스템에서 승인 압축 비율 제어를 이용한 TCP 성능 개선 (The Performance Improvement using Rate Control in End-to-End Network Systems)

  • 김광준;윤찬호;김천석
    • 한국정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.45-57
    • /
    • 2005
  • 본 논문에서는 종단간 네트워크 시스템에서 전송 율 기반하의 혼잡 제어를 제안하여 양방향 TCP 연결의 성능을 개선한다. TCP의 패킷과 승인들은 종단 시스템의 공통 버퍼를 공유하기 때문에 소스노드에 패킷과 승인이 집단적으로 도착되는 승인 압축 결과를 초래함으로서 불공성과 처리 율이 감소한다. 양방향 트래픽에 의한 처리율 감소는 매우 중요하다. TCP 비율제어를 이용한 백그라운드 트래픽이 2.5Mbps에서 5.0Mbps로 대역폭이 높아짐으로서 중간 노드의 혼잡이 어느 정도 해소되어 2.5Mbps에서 나타낸 것보다 왕복 지연 시간에 대한 처리 율이 적어짐으로서 연결의 효율성이 증가한다. 또한 백그라운드 트래픽을 7.5Mbps로 설정한 지터 처리 율에 대한 시뮬레이션 결과는 혼잡을 제어함으로서 2.5Mbps나 5.0Mbps에 발생한 지터 처리 율보다 개선됨으로서 제안된 비율 제어 방식의 연결 효율성의 성능 개선이 이루어짐을 알 수 있다.

혼합구조의 성능 향상을 위한 개선된 접합부의 개발 (II): 개선된 접합방식의 성능확인을 위한 모형실험 및 해석 (Developments of Advanced Connection Type for Improvements of Mixed Structures (II))

  • 윤익중;노병철;김문겸;조성용
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.207-214
    • /
    • 2008
  • 본 논문에서는 연계논문에서 제안된 혼합구조 접합부의 개선정도를 확인하기 위하여 2개의 혼합구조 실험체에 대하여 4절점 휨시험을 수행하였다. 혼합구조 접합부의 거동 분석을 위하여 3차원 비선형해석 결과와 실재하 실험 결과를 하중-처짐 관계, 하중-변형률 관계, 접합부 개구폭, 균열과 파괴모드를 통하여 비교하였다. 3차원 비선형 해석을 위하여 접촉요소를 사용하였으며 해석프로그램은 범용 구조 해석프로그램인 아바쿠스를 이용하였다. 실험과 해석의 결과로부터 제안된 L 모양의 접합부가 휨하중에서 기존안보다 강성이 크게 나타났으며, 보다 나은 구조적 성능을 나타냄을 확인하였다.