• 제목/요약/키워드: General cable

검색결과 174건 처리시간 0.03초

HANbit ACE64 ATM 교환기 시스템의 Twinax 케이블 모델링 (Twinax Cable Modeling for Use in HANbit ACE64 ATM Switching Systems)

  • 남상식;박종대
    • 한국통신학회논문지
    • /
    • 제24권12A호
    • /
    • pp.1985-1991
    • /
    • 1999
  • 본 논문은 HANbit ACE64 ATM 교환기 시스템의 데이터 경로인 IMI(Inter Module Path)에 사용되는 고속 전송선로인 Twinax 케이블을 two-port lumped Spice-network 모델로 구현하기 위해 lumped 네트워크 요소와 수학적 함수를 사용하여 개발하였다. 사용된 요소들은 저항성분과 주파수의존 전압제어 소스로 구성되어 있고 Hspice 수학적 함수인 FREQ, DELAY, POLY를 사용하여 구현하였다. 구현된 모델을 사용하여 케이블 길이와 종류에 따른 각종 노이즈 분석을 실시하여 그 특성을 비교 분석하였다.

  • PDF

무선 MEMS 센서를 이용한 초고층 건물 수평 상시진동 계측의 유효성 평가 (The Evaluation of Effectiveness on Horizontal Ambient Vibration Measurement of Tall Building Using Wireless MEMS Sensor)

  • 이종호;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.51-58
    • /
    • 2018
  • Recently, measuring instruments for SHM of structures had being developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to its absence of triboelectric noise and elimination of the requirement for cumbersome cable. However, the research on the tall buildings with relatively small vibration levels is insufficient. Therefore, in this paper, we used the wireless MEMS sensor and iPad to compare and analyze the vibration measurements of three tall buildings and two towers.

가지형 트리의 열화진단을 위한 방전통계량에 관한 연구 (A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree)

  • 신성권;김경민;김탁용;이덕진;박창옥;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.

  • PDF

A Study of the Development of a Radial Pleat Module for Low Pressure Using an Ultrafiltration Membrane

  • Seo, Il-Gun;Shin, Se-Jong;Byoung-Ryul;Song, Hee-Yeol
    • Korean Membrane Journal
    • /
    • 제4권1호
    • /
    • pp.7-11
    • /
    • 2002
  • A radial pleat module using a polysulfone membrane was developed. The permeation characteristics of the radial pleat module were compared with those of a flat plate module. The average module efficiency of the radial pleat module for the applied pressure range was 82% and was always greater than that of the spiral wound module. For the radial pleat module, in general, as the applied pressure increases, the flux increases and the rejection reduces. The concentration polarization causes the decrease of the flux for the long time operation. But it has been found that the radial pleat module is more efficient for the reduction of the concentration polarization because it has the more effective area per unit volume and can induce the turbulent flow in the module.

무선 MEMS 센서를 이용한 저층건물 상시진동계측의 유효성 평가 (The Evaluation of Effectiveness on Horizontal Transient Vibration Measurement of Low-Rise Building Using Wireless MEMS Sensor)

  • 이종호;윤성원
    • 한국공간구조학회논문집
    • /
    • 제17권3호
    • /
    • pp.57-64
    • /
    • 2017
  • Recently, measuring instruments for SHM of structures had being developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to its absence of triboelectric noise and elimination of the requirement for cumbersome cable. Preliminary studies on the continuous vibration measurement of high-rise buildings using MEMS sensors have been carried out. However, the research on the low-rise buildings with relatively small vibration levels is insufficient. Therefore, in this paper, we used the wireless MEMS sensor to compare and analyze the vibration measurements of three low-rise buildings.

파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단 (Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction)

  • 김충배;이정빈;임장섭;장영학;이진;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

Design of a Biconical Antenna with Cylindrical Loads for EMI Test Site Validation above 1 GHz

  • Kong, Sung-Sik;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제8권1호
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, a biconical type antenna is proposed for EMI test site validation above 1 GHz. To achieve broadband and omni-directional radiation patterns required by international standard(CISPR), the proposed antenna consists of general bicones with cylindrical loads and adopts side feeding method to minimize the influence on H-plane pattern due to feeding cable, balun, and connector. The radiation patterns of the fabricated antenna are measured and the results are compared with CISPR criteria and commercial antenna in our interest frequencies. Although the proposed antenna has a few problems in frequency range of 1 GHz to 2 GHz, it has relatively better performance than commercial antenna.

고압 회전기에서 코일 단부의 전계 해석 (Field analysis of end_turn coil of HV induction motor)

  • 박승배;김도완;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.70-72
    • /
    • 1998
  • Because of using PWM inverters and converters. The problems of insulation breakdown is emerging in both high voltage motors and general motors. In conventional methods, the viewpoint of surge problems is wave propagation with or without cable and inverter. For the purpose of knowing the situation of insulation breakdown, the end-turn coil of windings in the motor winding insulation structure is modelled by FEM, and field analysis of that is done. For first step, only end-turn coil is modelled and the model is simulated with FEM by approximating the resistivity of metallic foil surrounding insulation layers with having nonlinear property. Next, the result of simulation with nonlinear resistivity are compared with the result of linear resistivity. Because of microscope analysis, there is the problem of generalization but the situation of corona discharge in end-turn coil will be explained from this simulation.

  • PDF

Channel Equalization for High-speed applications using MATLAB

  • Kim, Young-Min;Park, Tae-Jin
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권2호
    • /
    • pp.57-66
    • /
    • 2019
  • This paper compared the performance with an overview of channel equalization techniques used in high-speed serial transceivers, including the homogeneous architecture and associated components for the GHz interconnect of backplane and cable channels. It also used the MATLAB tool to present system analysis and simulation results for continuous time equivalent structures. In the case of conventional continuous equalization, high frequency deficits occur due to the use of a comparator that is difficult to implement as well as the low speed limit. In this paper, the channel equalization technique based on the power spectrum analysis of clocks was used to compensate for the frequency loss, and the application of the TX+Channel and TX+Equalizer filters enabled the measurement of attenuation and equivalence without comparators. The application of blender and band-pass filters at high speeds also showed significant effectiveness.

무선 MEMS 센서를 이용한 보도교 진동 계측 (Vibration Measurements of Footbridges Using Wireless MEMS Sensor)

  • 이종호;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.101-108
    • /
    • 2019
  • Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, the low-cost wireless MEMS sensor has high noise density and transmits the signal wirelessly, so data transmission delay occurs during measurement. Therefore, the footbridges that was previously measured by a mobile phone in 2014 was remeasured using G-Link-200, iPad and iPhone to compare their performance.