DOI QR코드

DOI QR Code

Vibration Measurements of Footbridges Using Wireless MEMS Sensor

무선 MEMS 센서를 이용한 보도교 진동 계측

  • Lee, Jong-Ho (Dept. of Architecture, Seoul National University of Science and Technology) ;
  • Cheon, Dong-Jin (Dept. of Architecture, Seoul National University of Science and Technology) ;
  • Yoon, Sung-Won (School of Architecture, Seoul National University of Science and Technology)
  • 이종호 (서울과학기술대학교 건축과) ;
  • 천동진 (서울과학기술대학교 건축과) ;
  • 윤성원 (서울과학기술대학교 건축학부)
  • Received : 2018.12.05
  • Accepted : 2019.01.11
  • Published : 2019.03.15

Abstract

Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, the low-cost wireless MEMS sensor has high noise density and transmits the signal wirelessly, so data transmission delay occurs during measurement. Therefore, the footbridges that was previously measured by a mobile phone in 2014 was remeasured using G-Link-200, iPad and iPhone to compare their performance.

Keywords

References

  1. Sabato, A. (2015). Pedestrian bridge vibration monitoring using a wireless MEMS accelerometer board. Proceedings of the 2015 IEEE 19th International Conference on Computer Supported Cooperative Work in Design, Italy
  2. Do, K. Y., Yoon, S. W., & Kim, D. H., "Vibration Measurement of the Foot-Bridges Using Mobile-Phone", Journal of Korean Association for Spatial Structures, Vol.14, No.1, pp.61-68, 2014 https://doi.org/10.9712/KASS.2014.14.1.061
  3. Oliveira, C. S., "Fundamental Frequencies of Vibration of Footbridges in Portugal: From in Situ Measurements to Numerical Modelling", Shock and Vibration, Vol.2014, pp.1-22, 2014
  4. Hong, H. J. (2010). A Study on Vibration Analysis Method for Human Vibration Effect Assessment in Footbridges (Doctoral dissertation). Chonnam National University, Republic of Korea.
  5. Seoul Metropolitan Government, "Facility Design, Construction, and Maintenance Manuals", 2001
  6. Lee, J. H., Cheon, D. J., & Yoon, S. W., "The Evaluation of Effectiveness on Horizontal Ambient Vibration Measurement of Tall Building Using Wireless MEMS Sensor", Journal of Korean Association for Spatial Structures, Vol.18, No.2, pp.51-58, 2018 https://doi.org/10.9712/KASS.2018.18.2.51
  7. Shrestha, A., Dang, J., & Wang, X., "Development of a smart-device-based vibration-measurement system: Effectiveness examination and application cases to existing structure", Structural Control Health Monitoring, Vol.25, No.3, 2018
  8. Do, K. Y. (2014). Analysis of Natural Frequency through Vibration Measurement of Foot-bridges (Master's thesis). Seoul National University of Science and Technology, Republic of Korea.
  9. Lee, J. H., Cheon, D. J., & Yoon, S. W., "The Evaluation of Communication Distance Using Wireless MEMS Sensor in Building Structure", Journal of Korean Association for Spatial Structures, Vol.17, No.4, pp.93-102, 2017 https://doi.org/10.9712/KASS.2017.17.4.093
  10. G-Link-200 Datasheet (8400-0102) RevA-10 [Apparatus and software]. (2017). Williston, USA: Microstrain.
  11. WSDA-USB_Datasheet_8400-0074 [Apparatus and software]. (2017). Williston, USA: Microstrain.