• Title/Summary/Keyword: Gas Flow Measurement

Search Result 447, Processing Time 0.025 seconds

Experimental Study of Spray Characteristics on the Throttleable Dual Manifold Injector (이중 매니폴드 가변추력 분사기의 분무 특성에 관한 실험적 연구)

  • Youn, Jung-Soo;Kim, Sung-Hyuk;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.22-30
    • /
    • 2011
  • There is a many way of LPRE throttling methods, high-pressure-drop systems, dual-manifold injector, gas injection, multiple chambers, pulse modulation and movable injector components. Especially dual-manifold injector is essentially combines two fixed-area injectors into a common structure, with independent feed systems controlling flow to each injector manifold. In this paper, using indirect photography and liquid film thickness measurement with various injection pressure and tangential entry diameter to decide stability of spray over a wide thrust range in dual manifold injector.

Measurement of Velocity Field Change around Stern of LNG Carrier Double Body Model by Propeller (프로펠러에 의한 LNG 운반선 이중모형 선미의 속도변화 계측)

  • Kim, Byong-June;Choi, Soon-Ho;Kim, Hyoung-Tae;Van, Suak-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.5 s.143
    • /
    • pp.448-457
    • /
    • 2005
  • The experiment was performed at the large wind tunnel of the Chungnam National University to measure the velocity distribution around the stern of a Liquefied Natural Gas Carrier model. The data, mean velocity vectors of turbulent shear flows at the stern and near-wake including the propeller plane, were obtained by a five-hole Pilot tube for the double body model fixed inside the wind tunnel test section. The present result of the double body model shows a close agreement with the result of the lowing tank experiment performed by the KRISO for the same ship model. The characteristics of the LNG stern flow are discussed based on the measured velocity distribution. The data can be very useful for the validation of some numerical methods in computational fluid dynamics.

Characteristics of OLED Cells Fabricated with ITO Films Deposited by using Facing Target Sputtering (FTS) System (대향 타겟식 스퍼터링으로 증착한 ITO 박막이 적용된 유기발광다이오드의 특성)

  • Kim, Sangmo;Lee, Sangmin;Keum, Min Jong;Lee, Won Jae;Kim, Kyung Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.2
    • /
    • pp.71-75
    • /
    • 2018
  • In this study, we prepared OLED cell with ITO (Indium Tin Oxide) films grown on the glass substrate by facing targets sputtering. Before fabrication of OLED cells, we investigated properties of ITO films deposited at various sputtering conditions. To investigate properties of as-prepared films, we employed four-point probe, UV-VIS spectrometer, X-ray diffractometer (XRD), field emission scanning electron microscopy (FE-SEM), hall-effect measurement. As a results, as-prepared ITO films have high transmittance of over 85 % in the visible range (300-800 nm) and a resistivity of under $10^{-4}$ (${\Omega}-cm$). Their resistivity increased as a function of oxygen gas flow and substrate temperature. OLED cell with ITO films were fabricated by thermal evpoeartor. Properties of OLEDs cell referring to properties of ITO films.

Measurement of the Coating Temperature Evolution during Atmospheric Plasma Spraying (대기압 플라즈마 용사 공정에서의 기판 코팅 온도 영향 연구)

  • Lee, Kiyoung;Oh, Hyunchul
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.624-629
    • /
    • 2020
  • For more effective temperature control of atmospheric plasma sprayed (APS) zirconia thermal barrier coating, understanding of the parameters, which influence the substrate temperature, is essential and also more numerical results based on the experimental data are required. This study aims to investigate the substrate temperature control during an APS process. The APS process deals with air-cooled systems, plasma-gas flow, powder feed rate, robot velocity, and substrate effect on the substrate surface temperature control during the process. This systematic approach will help to handle the temperature control, and thus lead to better coating quality.

Study on the Characteristics of Long Wave Infrared Signal by Water Injection around the Exhaust Plume of the Micro-jet Engine (마이크로 제트엔진 배기플룸 주위 물 분사에 따른 장파장 적외선 신호특성 연구)

  • Yu, Gunwon;Choi, Seongman
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.2
    • /
    • pp.28-39
    • /
    • 2022
  • An experimental study was carried out to understand the characteristics of the long wave infrared signal emitted from the exhaust plume when water is sprayed around it. The micro-jet engine was used to generate the exhaust plume, and eight water spray nozzles were installed around the exhaust nozzle. Two water injection angles were applied, one is sparying parallel to the exhaust plume, and the other is spraying water into the exhaust plume. The measurement results are as follows. When spraying water parallel to the exhaust plume, the long wave infrared signal is decreased with water spray flow rate. When spraying water the exhaust plume, the long wave infrared signal shows a larger value than plume only.

Nitrogen Wash-Out Technique to Measure Functional Residual Capacity Based on Expired o2/Co2 Analysis (o2/Co2 분석기를 사용하여 폐의 기능적 잔기용량을 계측하는 질소세척법 개발)

  • Kim, Goon-Jin;Kim, Kyung-Ah;Lee, Jae-Hun;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • Functional residual capacity (FRC) is an important diagnostic parameter measured using $N_{2}$ analyzer. Since $N_{2}$ analyzer is expensive as well as cumbersome for use of noisy vacuum pump, the FRC measurement becomes possible only in large well-equipped hospitals. The present study introduced a new $TN_{2}$ wash-out technique to measure FRC by $O_{2}/CO_{2}$ analysis, which is relatively cheaper and much simpler to apply. Slower $O_{2}$ response was compensated for high frequency to be coincided with $CO_{2}$ response, thereby enabled indirect, but accurate $N_{2}$ concentration measurement. FRC was estimated by continuous integration of expired $N_{2}$ volume obtained with air flow signal. Experiment with 3 L syringe, a standard calibration device recommended by the American Thoracic Society, demonstrated less than 1% error at 0, 1, and 2 L. Correlation coefficient was almost ideal, guaranteeing linear estimation of FRC. The present technique is inexpensive and simple to apply, thus should he of great convenience.

Small Turbojet Engine Test and Uncertainty Analysis (소형 터보제트 엔진 시험 및 불확도 분석)

  • Jun, Yong-Min;Yang, In-Young;Nam, Sam-Sik;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.118-126
    • /
    • 2002
  • The Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute and has been being operated for the gas turbine engines in the class of 3,000 lbf thrust. To enhance the confidence level of AETF to the international level, a series of studies and facility modification have been conducted to improve the measurement uncertainty and reliability. In this paper, some part of the facility evaluation tests performed with a single spool turbojet engine are introduced. Tests were performed simulating the flight conditions as steady state, sea level for various flight speeds (i.e., Mn=0.3, 0.5, 0.7, 0.9). The obtained test results are compared with the predicted values of the engine DECK. The measurement uncertainties of airflow, net thrust, fuel flow and SFC showed 0.791~0.914%, 0.851~1.706%, 1.372~7.348% and 1.642~5.205%, respectively. Thus, from this research, the improvement methods of uncertainties on AETF has been confirmed.

A Study on the Optical Characteristics of Multi-Layer Touch Panel Structure on Sapphire Glass (Sapphire Glass 기반 다층박막 터치패널구조의 광학특성 연구)

  • Kwak, Young Hoon;Moon, Seong Cheol;Lee, Ji Seon;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.168-174
    • /
    • 2016
  • A conductive oxide-based sapphire glass indium tin oxide/metal electrode and the optical coating, through patterning process was studied in excellent optical properties and integrated touch panel has a high strength. Indium tin oxide conductive oxides of the sapphire glass to 0.3 A at DC magnetron sputtering method of 10 min, gas flow Ar 10 Sccm Ar, $O_2$ 1.0 Sccm the formation conditions of the thin film after annealing at $550^{\circ}C$ for 30min was achieved through a 86% transmittance. In addition, the coating 130 nm hollow silica sol-gel was to improve the optical transmittance of the indium tin oxide to 91%. For the measurement by the modeling hollow silica sol by Macleod simulation and calculated the average values of silica part to the presence or absence in analogy to actual. Refractive index value and the actual value of the material on the simulation the transmittance difference is it does not completely match the air region similar to the actual value (transmission) could be confirmed that the measurement is set to a value of between 5 nm and 10 nm.

A Study on Temporal Measurement of Size and Concentration for Soot Aggregates among Exhaust Emissions in Diesel Engines (디젤기관 배기 배출물에 있어서 매연 응집체 크기 및 농도의 시간적 계측에 관한 연구)

  • Bae, Myung-Whan;Kamimoto, Takeyuki;Bae, Chang-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.116-124
    • /
    • 2007
  • An optical method to measure the size and number density of soot aggregates in diesel exhaust has been proposed in this study. Two laser beams in co-axial alignment transmit a soot loaded exhaust gas flow, and the transmittance at each wavelength is detected by a photo diode simultaneously. The volume equivalent diameter and number density of soot aggregates in the optical path can be theoretically given by the transmittance values measured at two wavelengths. A test conducted by a single cylinder, 4 cycle, small and DI diesel engine shows that the temporal variations of the size and number density of soot aggregates in the diesel exhaust can be measured by the proposed method at a transient mode operation. It is found that the volume equivalent diameter varied temporally from 70 to 110 nm during the period that high soot concentration is observed. One can also conclude that the optical length longer than 1 m in the dynamic range regarding this method is preferable for measuring soot concentration at the level of $1\;mg/m^3$.

Examining the Effect of L/W Ratio on the Hydro-dynamic Behavior in DAF System Using CFD & ADV Technique (전산유체역학과 ADV기술을 이용한 장폭비의 DAF조내 수리흐름에 미치는 영향 연구)

  • Park, No-Suk;Kwon, Soon-Bum;Lee, Sun-Ju;Bae, Chul-Ho;Kim, Jeong-Hyun;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.421-428
    • /
    • 2005
  • Dissolved air flotation (OAF) is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In this study, we investigated the effect of L/W (L; Length, W; Width) on the hydro-dynamic behavior in DAF system using CFD (Computational Fluid Dynamics) and ADV (Acoustic Doppler Velocimetry) technique. The factual full-scale DAF system, L/W ratio of 1:1, was selected and various L/W ratio (2:1, 3:1, 4:1 and 5:1) conditions were simulated with CFD. For modelling, 2-phase (gas-liquid) flow equations for the conservation of mass, momentum and turbulence quantities were solved using an Eulerian-Eulerian approach based on the assumption that very small particle is applied in the DAF system. Also, for verification of CFD simulation results, we measured the factual velocity at some points in the full-scale DAF system with ADV technique. Both the simulation and the measurement results were in good accordance with each other. As the results of this study, we concluded that L/W ratio and outlet geometry play important role for flow pattern and fine bubble distribution in the flotation zone. In the ratio of 1:1, the dead zone is less than those in other cases. On the other hands, in the ration of 3:1, the fine bubbles were more evenly distributed.