Abstract
Functional residual capacity (FRC) is an important diagnostic parameter measured using $N_{2}$ analyzer. Since $N_{2}$ analyzer is expensive as well as cumbersome for use of noisy vacuum pump, the FRC measurement becomes possible only in large well-equipped hospitals. The present study introduced a new $TN_{2}$ wash-out technique to measure FRC by $O_{2}/CO_{2}$ analysis, which is relatively cheaper and much simpler to apply. Slower $O_{2}$ response was compensated for high frequency to be coincided with $CO_{2}$ response, thereby enabled indirect, but accurate $N_{2}$ concentration measurement. FRC was estimated by continuous integration of expired $N_{2}$ volume obtained with air flow signal. Experiment with 3 L syringe, a standard calibration device recommended by the American Thoracic Society, demonstrated less than 1% error at 0, 1, and 2 L. Correlation coefficient was almost ideal, guaranteeing linear estimation of FRC. The present technique is inexpensive and simple to apply, thus should he of great convenience.
Keywords
Functional residual capacity$N_{2}$ wash-out technique; Respiratory gas analysis; Dynamic characteristic compensation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. F. Ganong, 'Pulmonary function', In: Review of medical physiology, Section VII. pp. 507-509, LANGE Medical Publications, Los Altos, U. S. A., 1981
2 F. S. Grodins and S. M. Yamashiro, 'Respiratory function of the lung and its control', pp. 8-16, Macmillan Publishing Co., Inc., New York, 1978
3 차은종, '호흡기 시스템의 측정', In: 의용생체공학, 제 9장, pp. 509-598, 의공학교육연구 회 역편, 여문 각, 1993
4 T. D. East and E. A. East, 'Nitrogen analyzers', In: Encyclopedia of medical devices and instrumentation, vol. 3, pp. 2053-2058, Ed. by J. G. Webster, John Wiley & Sons, 1988
5 American Thoracic Society, 'Standardization of spiromety 1994 update', Am. J. Respir. & Grit. Gare Med., vol. 152, pp. 1107-1136, 1995   DOI   ScienceOn
6 차은종, 김경아, 김현식, '호흡 방해 효과를 최소화한 단방향 기류 밸브관', 대한민국 특허 출원 제 10-2002-000839호, 2002
7 김군진, 김경아, 이태수, 차은종, '호기가스농도 계측시스템의 동특성 분석', 제29회 대한 의용생체공학회 추계학술대회, P-50, 2003