• Title/Summary/Keyword: Gamma-rays

Search Result 587, Processing Time 0.034 seconds

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Simulation for Dose-Rate Latchup by Transient Radiation Pulse in CMOS Device (CMOS 소자에서 과도방사선펄스에 의한 Dose-Rate Latchup 모의실험)

  • Lee, Hyun-Jin;Lee, Nam-Ho;Hwang, Young-Gwan
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1185-1186
    • /
    • 2008
  • A nuclear explosion emits a transient radiation pulse like gamma rays. Gamma rays have a high energy and cause unexpected effects in semiconductor devices. These effects are mainly referred to dose-rate latcup and dose-rate upset. By transient radiation pulse in CMOS devices, dose-rate latchup is simulated in this paper.

  • PDF

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

Analysis of Proton Nuclear Reaction-Generated Nuclides for Different Proton Energy (양성자 에너지 변화에 따른 핵반응 생성핵종 분석)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.819-824
    • /
    • 2019
  • In this study, we proposed a method for identifying isotopes generated from high-energy proton $^{nat}Pb$(p,xn) nuclear reactions through the difference of gamma rays generated through nuclear reactions using different proton energies. The experiment was performed by using a high energy proton generated from a 100 MeV proton linear accelerator of the Korea Atomic Energy Research Institute. Gamma rays generated by various nuclides generated through proton nuclear reactions were measured using a gamma-ray spectroscopy system composed of HPGe detectors. Gamma-ray standard sources were used for accurate energy calibration and efficiency measurements of HPGe gamma-ray detectors. For the proposed method, 100 and 60 MeV proton energy beams were used for the same natural lead samples. This method was found to be very effective in identifying nuclides produced by comparing gamma rays generated from the same sample with each other. The results of this study are expected to be very effective in obtaining other proton nuclear reaction results in the future.

Genotoxicological safety of the Gamma-Irradiated Medicinal Herbs in the Micronucleus Test Using CHO Cells In Vitro (CHO 세포에서의 소핵시험을 이용한 감마선조사 생약재의 안전성에 관한 유전독성학적 평가)

  • 조성기
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.5
    • /
    • pp.952-957
    • /
    • 1997
  • The three medicinal herbs-Curcuman longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays were tested for their possible genotoxicity. The methanol-soluble and water-soluble fractions of the 10kGy gamma-irradiated herbs were examined in cultured Chinese hamster ovary(CHO) cells for their ability to induce micronuclei. No mutagenicity of each test material was detected in the assay with or without metabolic activation. The safety of the herbs irradiated with gamma rays at practical doses needs further investigations using in vivo genotoxicity and chronic and reproductive toxicity tests.

  • PDF

Genotoxicological Safety of the Gamma Irradiated Medicinal Herbs in the salmonella typhimurium Reversion Assay (복귀돌연변이시험을 이용한 감마선조사 생약재의 안전성에 관한 유전독성학적 평가)

  • 조성기;육홍선;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.5
    • /
    • pp.958-964
    • /
    • 1997
  • The three medicinal herbs-Curcuma longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays have been tested for their possible genotoxicity. The methanol-soluble and water-soluble fractions of the 10kGy gamma-iradiated herbs were examined in the Salmonella typhimurium histidine reversion assy(Ames test) using S. typhimurium TA98, TA100 and TA102 as tester strains. No mutabenicity was detected in this assay with or without metabolic activation. The safety of the herbs irradiated with gamma rays at practical doses needs to be evaluated in further tests of genotoxicity in vivo and chronic and reproductive toxicity.

  • PDF

Genotoxicological Safety of the Gamma-Irradiated Medicinal Herbs (감마선 조사 생약재의 안전성에 관한 유전독성학적 평가)

  • 조성기
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.217-227
    • /
    • 1997
  • These experiments were performed to investigate the safety of the three medicinal herbs- Curcuma longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays in respect of genotoxicity. The methanol-soluble and water-soluble fractions of the methanol-water extracts of the 10 kGy gamma-irradiated herbs were examined in two short-term in vitro tests : (1) Salmonella typhimurium reversion assay (Ames test) in strain TA 98, TA 100 and TA 012 (2) Micronucleus test in cultured Chinese hamster ovary (CHO) cells. No mutagenicity was detected in the assays with or without metabolic activation. From these results, the safety of the herbs irradiated with gamma rays at practical doses could be revealed in further tests of genotoxicity in vivo, chronic and reproductive toxiceity.

  • PDF

Development of radioactive prospecting as tool for evaluating degree of granitic rocks weathering

  • Ishida Satoshi;Tsuchihara Takeo;Imaizumi Masayuki;Ohnishi Ryouichi
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.416-421
    • /
    • 2003
  • To develop an easy, low-cost method for evaluating the degree of weathering by radioactive prospecting, radioactive prospecting and the investigation of the degree of weathering were carried out in the southern Kitakami massif of Iwate Prefecture, Japan, in which weathering granitic rocks was distributed. Fifty outcrops in the study area were selected, and strength of the gamma-rays emitted from the weathering bedrock of $^{40}K,\;^{214}Bi,\;and\;^{208}Tl$ was measured for 15 minutes at each point. At the same points, soil hardness was measured on the surface of the outcrop with a Yamanaka soil penetration tester. In addition, 100cc samples of each outcrop were taken with the sampler. The samples were analyzed by XRD, and the kind of the rock-forming minerals containing K was identified. We then compared the degree of weathering and the radioactive prospecting results by using K as an indicator. The relation between $^{40}K/^{208}Tl$ gamma rays counting rate by the radioactive prospecting and the hardness index showed a positive correlation as a result of the investigation, and the correlation coefficient ($R^2$) was 0.67.Moreover, when $^{40}K/^{208}Tl$ gamma rays counting rate emitted from the bedrock was low, the number of rock-forming mineral species containing K was also low. Thus, it was found that $^{40}K/^{208}Tl$ gamma rays counting rate measured by the radioactive prospecting could be used as an indicator of the degree of weathering.

  • PDF

Daily adaptive proton therapy: Feasibility study of detection of tumor variations based on tomographic imaging of prompt gamma emission from proton-boron fusion reaction

  • Choi, Min-Geon;Law, Martin;Djeng, Shin-Kien;Kim, Moo-Sub;Shin, Han-Back;Choe, Bo-Young;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3006-3016
    • /
    • 2022
  • In this study, the images of specific prompt gamma (PG)-rays of 719 keV emitted from proton-boron reactions were analyzed using single-photon emission computed tomography (SPECT). Quantitative evaluation of the images verified the detection of anatomical changes in tumors, one of the important factors in daily adaptive proton therapy (DAPT) and verified the possibility of application of the PG-ray images to DAPT. Six scenarios were considered based on various sizes and locations compared to the reference virtual tumor to observe the anatomical alterations in the virtual tumor. Subsequently, PG-rays SPECT images were acquired using the modified ordered subset expectation-maximization algorithm, and these were evaluated using quantitative analysis methods. The results confirmed that the pixel range and location of the highest value of the normalized pixel in the PG-rays SPECT image profile changed according to the size and location of the virtual tumor. Moreover, the alterations in the virtual tumor size and location in the PG-rays SPECT images were similar to the true size and location alterations set in the phantom. Based on the above results, the tumor anatomical alterations in DAPT could be adequately detected and verified through SPECT imaging using the 719 keV PG-rays acquired during treatment.