• 제목/요약/키워드: Gamma source

검색결과 662건 처리시간 0.022초

Lost gamma source detection algorithm based on convolutional neural network

  • Fathi, Atefeh;Masoudi, S. Farhad
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3764-3771
    • /
    • 2021
  • Based on the convolutional neural network (CNN), a novel technique is investigated for lost gamma source detection in a room. The CNN is trained with the result of a GEANT4 simulation containing a gamma source inside a meshed room. The dataset for the training process is the deposited energy in the meshes of different n-step paths. The neural network is optimized with parameters such as the number of input data and path length. Based on the proposed method, the place of the gamma source can be recognized with reasonable accuracy without human intervention. The results show that only by 5 measurements of the energy deposited in a 5-step path, (5 sequential points 50 cm apart within 1600 meshes), the gamma source location can be estimated with 94% accuracy. Also, the method is tested for the room geometry containing the interior walls. The results show 90% accuracy with the energy deposition measurement in the meshes of a 5-step path.

Correlation Between Collimation-Corrected Peak Luminosity and Spectral Lag of Gamma-ray Bursts in the Source Frame

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.253-258
    • /
    • 2012
  • We revisit the relation between the peak luminosity $L_{iso}$ and the spectral time lag in the source frame. Since gamma-ray bursts (GRBs) are generally thought to be beamed, it is natural to expect that the collimation-corrected peak luminosity may well correlate with the spectral time lag in the source frame if the lag-luminosity relation in the GRB source frame exists. With 12 long GRBs detected by the Swift satellite, whose redshift and spectral lags in the source frame are known, we computed $L_{0,H}$ and $L_{0,W}$ using bulk Lorentz factors ${\Gamma}_{0,H}$ and ${\Gamma}_{0,W}$ archived in the published literature, where the subscripts H and W represent homogeneous and wind-like circumburst environments, respectively. We have confirmed that the isotropic peak luminosity correlates with the spectral time lag in the source frame. We have also confirmed that there is an anti-correlation between the source-frame spectral lag and the peak energy, $E_{peak}$ (1 + z) in the source frame. We have found that the collimation-corrected luminosity correlates in a similar way with the spectral lag, except that the correlations are somewhat less tight. The correlation in the wind density profile seems to agree with the isotropic peak luminosity case better than in the homogeneous case. Finally we conclude by briefly discussing its implications.

영상처리기반 감마선원 거리탐지 고속화 및 가시화 연구 (The Visualization and the Fast Detection of Gamma Radiation Source using Stereo Image Processing)

  • 황영관;이남호
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.2001-2006
    • /
    • 2016
  • 감마선 공간 탐지 장치는 감마선원을 스캔하여 영상화 한 후 스테레오 영상처리기술을 적용하여 탐지선원까지의 거리를 측정한다. 또한 실제 공간의 방사선원에 대한 분포 정보를 제공해 준다. 본 논문에서는 감마선 탐지장치가 3차원 공간상에서 장치로부터 선원을 찾기 위해 스캔하는 탐지 시간을 단축 시킬 수 있도록 감마선 탐지 고속화 알고리즘을 구현하였다. 그리고 감마선 조사 시험장에서 실험을 통해 그 성능을 검증하였다. 탐지시험 결과 고속 탐지를 위한 알고리즘을 적용할 경우 단일선원을 탐지할 경우 좌 우 스테레오 영상 획득 시보다 약 35% 의 탐지 시간을 단축시킬 수 있음을 확인하였다. 또한 사용자에게 방사선 공간분포 정보를 효율적으로 전달하기 위한 감마선원 분포의 입체 가시화를 구현하여 방사선원에 대한 정보를 제공할 수 있도록 하였다.

스테레오 기반 감마선원 탐지 및 가시화에 관한 연구 (Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector)

  • 박강택;이남호;차한주
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1100-1102
    • /
    • 2015
  • 본 논문에서는 스테레오 기반 감마선원 탐지장치를 통해 감마선원을 포함하는 공간을 래스터 스캔방식으로 스캔하여 가시광영상과 감마선영상을 획득하고, 스테레오 감마선 탐지장치로부터 선원까지의 거리와 방향에 대한 3차원 정보 획득 및 가시화를 수행하였다. 탐지장치의 구성은 감마선원 탐지를 위한 방사선 검출부, 선원탐지를 위해 래스터스캔방식의 스캔을 위한 팬틸트 그리고 가시광영상을 위한 CCD 카메라로 이루어진다. 선원에 대한 공간분포를 측정하기 위해 스테레오 구조의 장치를 구현하였으며 스테레오 영상획득을 위해 CCD 카메라와 감마선 탐지장치는 각각 2대로 구성하였다. 탐지선원에 대한 분포를 나타내기 위해 감마선 탐지 장치와 가시광 카메라에 대한 보정을 수행하였고, 각각의 카메라에 대한 스테레오 보정을 수행한 후 가시광영상과 감마선영상 중첩을 통해 감마선원에 대한 분포를 나타내었다. 좌, 우 분포영상에 대한 정류화처리 후 스테레오 영상에 대한 가시화결과를 도출하였다.

  • PDF

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

방사성물질의 분포특성에 따른 외부 감마피폭해석 (Analysis of the Distributional Effects of Radioactive Materials on External Gamma Exposure)

  • 한문희;김은한;서경석;황원태;최영길
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.211-218
    • /
    • 1998
  • 감마선원과 피폭자 사이의 거리, 방사선원의 크기 그리고 평균 감마에너지에 따른 외부 감마 피폭선량률의 변화를 분석하였다. 임의 형태로 공기중과 지표에 침적된 방사성물질로부터 외부 감마 피폭선량을 평가하기 위해 개발된 방법을 이용하여 분석을 수행하였다. 공기중의 점선원과 피폭자 사이의 거리가 10 m 이내로 짧은 경우에는 평균 감마에너지가 0.07 MeV에서 피폭선량률이 최소값을 나타내고, 거리가 20 m 이상으로 멀어지면 감마에너지의 증가에 따라 계속적으로 피폭선량률이 증가한다. 반경 40 m 이상의 반구형태의 방사능 구름으로부터 반구의 중심에 위치한 피폭자의 경우에는 감마에너지 증가에 따라 계속적으로 피폭선량률이 증가한다. 지표에 침적된 방사선원으로부터 피폭을 받는 경우에는 지표선원의 면적크기에 상관없이 0.07 MeV에서 최소 피폭선량률이 나타난다. 분석결과 방사선원의 분포형태와 평균 감마에너지가 외부 감마피폭선량의 변화에 큰 영향을 미치고 있음을 알 수 있었다.

  • PDF

A field determination method of D-T neutron source yields based on oxygen prompt gamma rays

  • Xiongjie Zhang;Bin Tang ;Geng Nian;Haitao Wang ;Lijiao Zhang ;Yan Zhang ;Rui Chen ;Zhifeng Liu ;Jinhui Qu
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2572-2577
    • /
    • 2023
  • A field determination method for small D-T neutron source yield based on the oxygen prompt gamma rays was established. A neutron-gamma transport equation of the determination device was developed. Two yield field determination devices with a thickness of 20 mm and 50 mm were made. The count rates of the oxygen prompt gamma rays were calculated using three energy spectra processing approaches, which were the characteristic peak of 6.13 MeV, the overlapping peak of 6.92 MeV and 7.12 MeV, and the total energy area. The R-square of the calibration curve is better than 94% and the maximum error of the yield test is 5.21%, demonstrating that it is feasible to measure the yield of D-T neutron source by oxygen prompt gamma rays. Additionally, the results meet the requirements for field determination of the conventional D-T neutron source yield.

스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구 (The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector)

  • 황영관;이남호;이승민
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • 전 세계적으로 전력생산을 위해 원전 증설이 지속적으로 증가하고 있으며 이에 따라 노후 원전에 대한 해체 및 원전사고에 대한 관심이 증가하고 있다. 원전 사고 시 발생되는 감마선원의 누출은 신속하고 정확한 탐지해야 그 피해를 최소화 시킬 수 있다. 기 개발된 장비는 선원에 대한 방향정보만을 나타내고 있어 정확한 공간상의 분포를 알 수 없다. 본 논문에서 개발한 스테레오 감마선탐지장치는 누출된 감마선원에 대한 분포를 측정할 수 있도록 구현하고 거리탐지를 위한 알고리즘을 적용하였다. 거리탐지를 위하여 스테레오 보정을 LED광과 보정패턴을 사용하여 진행하였고, LED 광원과 감마선원을 대상으로 성능시험을 진행하였다. 성능시험 결과 두 실험에서 5%이하의 오차를 갖게 됨을 확인하였다. 본 논문의 결과는 향후 고속 경량화 된 감마선 영상화 장치 개발을 위한 자료로 활용될 것이다.

HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발 (Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.119-123
    • /
    • 2013
  • HPGe 검출기를 사용하는 감마 분광분석계의 건전성을 점검하기 위한 실험실 선원이 개발되었다. 점검 선원은 0.154 mm 이하의 라듐이 풍부한 토양을 밀봉된 원통형 시료 용기에 담은 것으로, 검출기 교정에 사용할 12 개의 감마선이 방출된다. 점검 선원의 스펙트럼은 1년 동안 1개월 간격으로 측정하였으며, 스펙트럼에 나타난 감마선 피크들의 특성을 조사하였다. 감마 분광분석계가 정상일 때 라듐과 그 붕괴 생성물에서 3% 이상 방출률을 갖는 감마선들의 피크면적과 반치폭은 77 keV 피크를 제외하고는 각각 표준편차 2%와 3% 이내에서 일정하였다. 따라서 점검 선원은 77 keV부터 2202 keV까지 영역에 있는 10개의 피크를 사용하여 분광분석계의 건전성을 점검하는데 충분한 것으로 판단되었다.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.