• Title/Summary/Keyword: Functional measurement error

Search Result 38, Processing Time 0.03 seconds

Comment on "Estimation of Net Radiation in Three Different Plant Functional Types in Korea" (한국의 세 개의 다른 식생기능형태에서의 순복사 추정 논문에 대한 의견)

  • Kang, Min-Seok;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.3
    • /
    • pp.118-122
    • /
    • 2009
  • Net Radiation ($R_N$) is the major driving force for biophysical and biogeochemical processes in the terrestrial ecosystems, which is one of the most critical variables in both measurement and modeling. Despite its importance, there are only 10 weather stations conducting $R_N$ measurements among the 544 stations operated by Korea Meteorological Administration (KMA; KMA, 2008). The measurement of incoming shortwave radiation ($R_S{\downarrow}$) is, however, conducted at 22 stations while that of sunshine duration is conducted at all the manned stations. In this context, the recent research for estimating $R_N$ using $R_S{\downarrow}$ in Korean peninsula by Kwon (2009) is of great worth. The author used a linear regression and the radiation balance methods. We generally agree with the author that, in terms of simplicity and practicality, both methods show reliable applicability for estimating $R_N$. We noted, however, that the author's experimental method and analysis need some clarification and improvement, that are addressed in the following perspectives: (1) the use of daily integrated data for regression, (2) the use of measured albedo, (3) the use of linear coefficients for whole year data, (4) methodological improvement, (5) the use of sunshine duration, and (6) the error assessment.

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.

Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.272-281
    • /
    • 2014
  • In electrical impedance tomography (EIT), modified Newton Raphson (mNR) method is widely used inverse algorithm for static image reconstruction due to its convergence speed and estimation accuracy. The unknown conductivity distribution is estimated iteratively by minimizing a cost functional such that the residual error namely the difference in measured and calculated voltages is reduced. Although, mNR method has good estimation performance, EIT inverse problem still suffers from ill-conditioned and ill-posedness nature. To mitigate the ill-posedness, generally, regularization methods are adopted. The inverse solution is highly dependent on the choice of regularization parameter. In most cases, the regularization parameter has a constant value and is chosen based on experience or trail and error approach. In situations, when the internal distribution changes or with high measurement noise, the solution does not get converged with the use of constant regularization parameter. Therefore, in this paper, in order to improve the image reconstruction performance, we propose a new scheme to determine the regularization parameter. The regularization parameter is computed based on residual error and updated every iteration. The proposed scheme is tested with numerical simulations and laboratory phantom experiments. The results show an improved reconstruction performance when using the proposed regularization scheme as compared to constant regularization scheme.

Development of Sensor and Signal Duplicator for Building Automation (빌딩 자동제어용 센서 및 신호의 듀플리케이터(Duplicator) 개발)

  • Jang, Kyeong-Uk;Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.184-187
    • /
    • 2016
  • In this paper, we propose the sensor and the signal duplicator for the automatic building control. Developed duplicator realizes the sensor data collection apparatus and mimics the measured data and, thus, reduces the construction cost by using logical communication layer. Furthermore, the system supports the open protocols and can be associated with HMI(Human Machine Interface) used on the market. Developed duplicator is proved to be functional within the real environment. Measurement error rate, operating temperature, and operating humidity show very good results by the certified testing apparatus and organization.

Reliability and Validity of Gait Assessment Tools for Elderly Person (노인의 보행에 대한 평가 도구의 신뢰도와 타당도 조사 연구)

  • Kim, Jae-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Purpose: The examine the Reliability and Validity of the modified Emory Functional Ambulation Profile (mEFAP), Tinetti. Gait (TG), Timed Up & Go Tes t (TUG), Comfortable Gait Speed (CGS), Berg Balance Scale (BBS) in assessing gait function and balance in elderly person. Methods: The 45 community-dwelling subjects were participated in this study. Reliability was determined by intra-class correlation coefficient (ICC$_{3,1}$), Bland and Altman method (Standard Error of Measurement (SEM), Smallest Real Difference (SRD)). Results: Validity was examined by correlation the mEFAP, TG, TUG, CGS, BBS. The intra-rater reliability were High (ICC$_{3,1}$ : mEFAP=0.95, TG=0.96, TUG=0.94, CGS=0.96, BBS=0.92) and Absolute reliability were excellent (SEM: mEFAP=1.90, TG=0.21, TUG=0.28 CGS=0.25, BBS=0.52), (SRD: mEFAP=5.26, TG=0.58, TUG=0.77, CGS=0.69, BBS=1.44). There were significant correlations between assessment tool (r=.0.58$\sim$0.78, p<0.01) indicating good validity. Our results provide strong evidence that the assessment tool has good reliability, validity for assessing elderly person undergoing rehabilitation. Conclusion: The gait assessment tool is a useful scale for measuring walking function and recovery in elderly person.

  • PDF

Implementation & Application of Instrumentation System on Performance Evaluation for Korea-Radio Train Control System (통신기반 열차제어시스템 성능평가용 계측시스템 구현 및 적용)

  • Lee, Jae-Ho;Lee, Kang-Mi;Park, Pyoung-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1777-1783
    • /
    • 2013
  • This study aims to implement an instrumentation system measuring and analysing real-time data of information flow between respective subunits composing train control system as the performance evaluation method for wireless communication based urban railway train control system under development for a Korean model. It analyses system functional requirements regarding subsystems composing wireless communication based train control system and test items for functions presented in each specification and examines data and measurement point for measuring according to test items in order to implement an instrumentation system. And, it clearly defines requirements of an instrumentation system to avoid malfunction or error in operation of train control system. It reviews data processing method and display method for effective analysis of data flow between respective subunits with measured data, designs and makes an instrumentation system. Ultimately, it applies to a performance test of train control system and makes sure an instrumentation system in normal working order.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

The Effects of Multi Joint-Joint Position Sense Training Using Functional Task on Joint Position Sense, Balance, Walking Ability in Patients With Post-Stroke Hemiplegia (기능적 과제를 통한 다관절 관절위치감각 훈련이 뇌졸중 환자의 관절위치감각, 균형, 보행능력에 미치는 효과)

  • Ko, Kyoung-hee;Choi, Jong-duk;Kim, Mi-sun
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.33-40
    • /
    • 2015
  • The purpose of this study was to investigate the effect of multi joint-joint position sense (MJ-JPS) training on joint position sense, balance, and gait ability in stroke patients. A total of 18 stroke patients participated in the study. The subjects were allocated randomly into two groups: an experimental group and a control group. Participants in the experimental group received MJ-JPS training (10 min) and conventional treatment (20 min), but participants in the control group only received conventional treatment (30 min). Both groups received training for five times per week for six weeks. MJ-JPS is a training method used to increase proprioception in the lower extremities; as such, it is used, to position the lower extremities in a given space. MJ-JPS measurement was captured via video using a Image J program to calculate the error distance. Balance ability was measured using Timed Up and Go (TUG) and the Berg Balance Scale (BBS). Gait ability was measured with a 10 m walking test (10MWT) and by climbing four flights of stairs. The Shapiro-Wilk test was used to assess normalization. Within-group differences were analyzed using the paired t-test. Between-group differences were analyzed using the independent t-test. The experimental group showed a significant decrease in error distance (MJ-JPS) compared to the control group (p<.05). Both groups showed a significant difference in their BBS and 10MWT results (p<.05). The experimental group showed a significant decrease in their TUG and climbing results (p<.05), but the control group results for those two tasks were not found to be significant (p>.05). There was significant difference in MJ-JPS and by climbing four flights of stairs on variation of pre and post test in between groups (p<.05), but TUG and BBS and 10MWT was no significantly (p>.05). We suggest that the MJ-JPS training proposed in this study be used as an intervention to help improve the functional activity of the lower extremities in stroke patients.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Digital Blood Pressure Estimation with the Differential Value of the Arterial Pulse Waveform (맥파의 차동값에 의한 디지털 방식의 혈압 추정 기법)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.6
    • /
    • pp.135-142
    • /
    • 2016
  • We proposed the new method to estimate the blood pressure with the differential value of the digital arterial pulse waveform and BP relation equation. To get the digital arterial pulse waveform, we use the arterial pulse waveform measurement system that has digital air-pressure sensor device and smart phone. The acquired digital arterial pulse waveforms are classified as hypertension group, normal group, and hypotension group, and we can derive the average differential value between the highest point and lowest point of a single waveform of individuals along with the group. In this study, we found the functional correlation between the blood pressure and differential value as a form of BP relation equation through the regression process on the average of differential value and blood pressure value from a tonometer. The Experimental results show the BP relation equation can give easy blood pressure estimation method with a high accuracy. Although this estimation method has over 66 % error rate and does not give the high level of the accuracy for the diastolic compares to the commercial tonometer, the estimation results for the systolic show the high accuracy that has less than 10 % error rate.